| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE KARANJA NAME OF WORK: COMPREHENSIVE MAINTENANCE OF B/R AND E/M WORKS LIKE OF STAND BY LT CABLES, REPAIR TO DG SET SHEDS, CONTROL PANELS, SWITCHGEARS, AMF PANELS, EARTHINGS ETC FOR DG SETS INSTALLED AT VARIOUS LOCATION AT NAVAL STATION KARANJA. CONTRACT AGREEMENT: CWE KJ(K)- OF 2026 - 2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | Material and labour for carrying out repairs to AMF panel of 15 KVA to 200 KVA DG set at various installation inclduing study, tracing out circuit, testing, replacing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioning complete all as specified and as directed. (Note: Spares like Volt meter, CT, power contactor required for repair will be measured and paid seperately under relevant items. |
| 3 | Supply and fix microprocessor based multifunction controller with necessary accessories complete suitable for DG sets operation of capacity 500 KVA and showing the various parameters such as volt, ampere, frequency, RPM etc complete as per manufacturer of DG set with site requirment including removal of existing unserviceable one complete all specified and as directed. |
| 4 | Supply and fix microprocessor based multifunction controller with necessary accessories complete suitable for DG sets operation of capacity 625 KVA and showing the various parameters such as volt, ampere, frequency, RPM etc complete as per manufacturer of DG set with site requirment including removal of existing unserviceable one complete all specified and as directed. |
| 5 | Supply and fix microprocessor based multifunction controller with necessary accessories complete suitable for DG sets operation of capacity 200-320 KVA and showing the various parameters such as volt, ampere, frequency, RPM etc complete as per manufacturer of DG set with site requirment including removal of existing unserviceable one complete all specified and as directed. |
| 6 | Supply and fix microprocessor based multifunction controller with necessary accessories complete suitable for DG sets operation of capacity 400 KVA and showing the various parameters such as volt, ampere, frequency, RPM etc complete as per manufacturer of DG set with site requirment including removal of existing unserviceable one complete all specified and as directed. |
| 7 | Material and Labour for earthing with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32mm x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) type B1 using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point including testing on completion and taking down old u/s materials complete all as specified and directed. NOTE: (i) The earth chamber shall be constructed 0.50m away from the edge of earth pit and the cost of the same is deemed to be included in quoted unit rate. (ii) GI Strip and protection pipe upto 7.5m is deemed to be included in the quoted unit rate. (iii) GI watering pipe upto 1.2m s deemed to be included in the quoted unit rate. |
| 8 | Supply & Fixing,Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of following sizes incl taking out cable all as specified and directed |
| 9 | 3.5 core 70 Sqmm |
| 10 | 3.5 core 185 Sqmm |
| 11 | 3.5 core 240 Sqmm |
| 12 | 3.5 core 95 Sqmm |
| 13 | 3.5 core 120 Sqmm |
| 14 | 3.5 core 150 Sqmm |
| 15 | Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in Hard/dense soil including taking out faulty cable/cable covers and GI pipe complete all as specified and directed. |
| 16 | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed. |
| 17 | Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point. |
| 18 | Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made, LT cubical, double door panel with roof canopy, outdoor type suitable to accomodate the following accessories made out of CRCA sheet 3mm thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle, Inner cubicle should be made out of 2mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase, 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp, shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following : |
| 19 | (A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps – 01 No.(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 400 Amps – 01 No.(ii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 320 Amps – 01 No.(iii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 250 Amps – 01 No.(iv) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps – 01 No.(v) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 63 Amps – 01 No.(iv) Multi function meter having LCD Display, 96 x 96 sq.mm - 01 No(v) Current transformer of suitable ratio, Accuracy - 5VA, Class 1 (vi) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each(vii) Aluminium bus bar of Rating 700 Amp R-Y-B phases and Neutral.(viii) Base frame for cubical mounting made out of 40mm x 40mm x 6mm equal angle iron duly painted.(ix) Foundation for the panel should provided with PCC 1:4:8 using 40mm graded stone aggreagrs at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. |
| 20 | Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made, LT cubical, double door panel with roof canopy, outdoor type suitable to accomodate the following accessories made out of CRCA sheet 3mm thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle, Inner cubicle should be made out of 2mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase, 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp, shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following : |
| 21 | (A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 250 Amps – 01 No.(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps – 02 Nos.(ii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 63 Amps – 06 Nos.(iii) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(iv) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (v) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, (vi) Aluminium bus bar of Rating 500 Amp R-Y-B phases and Neutral.(vii) Base frame for cubical mounting made out of 40mm x 40mm x 6mm equal angle iron duly painted.(viii) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. (viii) Foundation for the panel should provided with PCC 1:4:8 using 40 mm graded stone aggregates at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. |
| 22 | Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made, LT cubical, double door panel with roof canopy, outdoor type suitable to accomodate the following accessories made out of CRCA sheet 3mm thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle, Inner cubicle should be made out of 2mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase, 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp, shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following : |
| 23 | (A) INCOMING - (i) On-load Changeover Switch I-O-II open execution, 4 pole - 100 Amps - 01 No(ii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps – 01 No.(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 63 Amps – 02 Nos.(ii) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(iii) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (iv) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, (v) Aluminium bus bar of Rating 300 Amp R-Y-B phases and Neutral.(vi) Base frame for cubical mounting made out of 40mm x 40mm x 6mm equal angle iron duly painted.(vii) Foundation for the panel should provided with PCC 1:4:8 using 40 mm graded stone aggregates at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. |
| 24 | Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made, LT cubical, double door panel with roof canopy, outdoor type suitable to accomodate the following accessories made out of CRCA sheet 3mm thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle, Inner cubicle should be made out of 2mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase, 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp, shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :u in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following : |
| 25 | (A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 200 Amps – 01 No.(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps – 01 No.(ii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 63 Amps – 03 Nos.(iii) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(iv) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (v) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each,(vi) Aluminium bus bar of Rating 300 Amp R-Y-B phases and Neutral.(vii) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted.(viii) Foundation for the panel should provided with PCC 1:4:8 using 40 mm graded stone aggregates at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. |
| 26 | Supply and fix for battery low maintenance lead acid of capacity 12 volts 150 AH with initial charging including removal of existing unserviceable one and hand over to store yard compete all as specified and as directed. |
| 27 | Supply and fix for battery low maintenance lead acid of capacity 12 volts 135 AH with initial charging including removal of exsting unserviceable one and hand over to store yard compete all as specified and as directed. |
| 28 | Supply and fix for battery low maintenance lead acid of capacity 12 volts 100 AH with initial charging including removal of extg unserviceable one and hand over to store yard compete all as specified and as directed by Engr-in charge. |
| 29 | Supply & fixing in repair of Contactor- 3/4 Pole,150 Amps/ 140 Amps up to 62.5 KVA DG Set AMF panel with replacement of lugs and checking of all connections etc including taking down u/s contactor complete all as specified and directed. |
| 30 | Supply & fixing in repair of Contactor- 3/4 Pole, 225 Amp/ 200 Amp for 62.5 to 150 KVA DG set AMF panel with replacement of lugs and checking of all connections etc taking down u/s contactor complete all as specified and directed. |
| 31 | Supply & fixing in repair of Contactor of 4 Pole, 250 Amps AMF PANEL of DG Set with replacement of cable lugs and checking of all connections etc taking down u/s contactor complete all as specified and directed. |
| 32 | Supply & fixing in repair of Contactor of 4 Pole, 320 Amps for AMF PANEL of DG Set with replacement of cable lugs and checking of all connections etc taking down u/s contactor complete all as specified and directed. |
| 33 | Supply & fixing in repair of Contactor of 4 Pole, 400 Amps for AMF PANEL of DG Set with replacement of cable lugs and checking of all connections etc taking down u/s contactor complete all as specified and directed. |
| 34 | Supply & fixing in repair of Self Engine Stop Relay Device for 63 KVA to 180 KVA DG set AMF panel etc complete all as directed and specified |
| 35 | Supply & fixing in repair of Self Engine Stop Relay Device for 200 KVA to 315 KVA DG set AMF panel etc complete all as directed and specified |
| 36 | Supply & fixing in repair of Self Engine Stop Relay Device for 400 KVA to 625 KVA DG set AMF panel etc complete all as directed and specified |
| 37 | Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 630 Amp 4pole 415 volts with sheet steel enclosure of made by 3.0mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed. |
| 38 | Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 400 Amp 4pole 415 volts with sheet steel enclosure of made by 3.0mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed. |
| 39 | Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 315 Amp 4pole 415 volts with sheet steel enclosure of made by 3.2mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed. |
| 40 | Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 200/250 Amp 4pole 415 volts with sheet steel enclosure of made by 3.0mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed. |
| 41 | Supply, in renewal of fabricating and testing of factory made/fabricated cubical type bypass panel double door outdoor type with degree of protection IP-65 conforming to IS-2147, suitable for 200KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated aluminium bus bar to interconnect the Change over No-01 to No-02 ,Onload Change over switch of capacity 315/320Amp 4pole 415 volts -02 No, R ,Y, B LED Indicating lamps provn of connecting incoming and outgoing cables with preper cable glands of adequate size and the angle iron frame of suitable size to mount the panel at height of 45cm from ground level with PCC platform casted in PCC1:3:6 type C-1 (20mm aggregate) of adequate thickness all as specified and directed. |
| 42 | Supply, in renewal of fabricating and testing of factory made/fabricated cubical type bypass panel outdoor type with degree of protection IP-65 conforming to IS-2147, suitable for 400 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated aluminium bus bar to interconnect the Change over No-01 to No-02 ,Onload Change over switch of capacity 630Amp 4pole 415 volts -02 No R ,Y, B LED Indicating lamps provn of connecting incoming and outgoing cables with cable glands of adequate size and the angle iron frame of suitable size to mount the panel at height of 45cm from ground level with PCC platform casted in 1:3:6 type C1 (20mm aggregate) of adequate thickness all as specified and directed. |
| 43 | Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 63 -100 Amps with thermal magnetic release breaking capacity 16 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed. |
| 44 | Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 125 Amps with thermal magnetic release breaking capacity 16 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed. |
| 45 | Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 160 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed. |
| 46 | Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 200 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed. |
| 47 | Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 250 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed. |
| 48 | Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 400 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed. |
| 49 | Material and Labour for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers all as specified |
| 50 | Supply & laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |