Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling floor hearth or wall tiling, cement concrete tiles including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises outside the MD land (The place of disposal shall be find out by contractor). |
| 2 | M&L for PCC 100mm thick type D-2 (1:4:8) using 40mm graded aggregate as in sub base all as specified and as directed. |
| 3 | M & L for Non skid coloured ceramic tiles 7 to 8 mm thick ( square/ rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of the tiles with and including 15mm thick screed bed in CM 1:4 complete all as specified. |
| 4 | M & L for Coloured glazed ceramic tiles in vertical surface area of tiles n exc 0.18 Sqm thick with and including 10 mm thick cm (1:4) backing coat and Triangular filliting at top of skirting, set and jointed in neat cement paste and pointed in coloured cement to match the shade of the tiles. |
| 5 | M&L virified ceramic tiles 8-10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match in floor including 15mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.Note : Engr-in-Charge will select sample from latest catalouge. |
| 6 | Ditto all as per item No 5 above but in skirting/ vertical surface including 10mm thick backing coat in CM 1:4 complete all as specified and as directed. |
| 7 | M & L for acid/ Chemical resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors complete all as specified and as directed. |
| 8 | M&L for 7-8mm thick engineering wooden flooring laid down over necessary apung/ polythene/ base cushion complete all as specified and as directed. |
| 9 | S&F in repair for 7-8mm thick wooden skirting complete all as specified and as directed. (Make : Hego/pergo) |
| 10 | Demolition of Stone granite slabs and tiles/ Interlocking paver blocks of any description or thickness in floors, aprons laid, bedded and pointed in any mortar and removing rubbish off the premises (outside MD land) etc complete all as specified and directed |
| 11 | M&L 18-20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, window- cills,cooking platforms, working table and like over 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed |
| 12 | M&L for 18-20 mm thick granite maching cut mirror polished as in skirting/vertical surfaces i.e jambs /risers and pillars etc and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, polishing and 10 mm thick backing coat in cement mortar 1:3 complete all as specified and directed. (colour of granite will be decided by the GE/Engr-in-Charge). |
| 13 | M&L for providing edge moulding to 18-20mm thick grenite incl machine polishing to edge to give high glossy finish etc complete. |
| 14 | M&L for cement concrete tiles 25CmX25CmX22 mm thick, machine pressed,(with grey cement & no pigments), set jointed and pointed in neat cement slurry in floors over and including 15 mm thick bedding layers in CM 1:3. all as specified & directed by engn-in-charge |
| 15 | M & L for machine pressed precast concrete interlocking paver blocks with grey cement and pigment, of any shape and size conforming to IS 15658:2006, 60 mm thickness, M-35 grade, laid over 25 mm thick sand bed, including all materials and labour, complete all as specified and as directed by Engineer-in-Charge. |
| 16 | M&L for 22-25mm thick, machine cut mirror polished,, Kota stone slab, as in floors, steps, landing, skirting etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of slab, including cutting, polishing etc. with and including 20mm thick screed bed in CM 1:4 complete all as specified. |
| 17 | Dismantling of wall and ceiling boards (fibre, pulp, insulation) or insulation boards, false ceiling, wall panneling & partation boards bonded wool, blanket slab incl aluminium grid frame work complete all as specified and as directed |
| 18 | M & L for Anodised aluminium snap grid frame work for false ceiling of grid size 605X605 mm with Hangers 2-4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats and expansion hold fasteners 12.5 mm dia. 40mm long with cement fiber board of 4mm thick of size 600 mm x 600mm (etc complete all as specified all as specified. |
| 19 | M&L for POP false ceiling using 600 x 900 x 12 mm thick plaster of paris with gypsum binder sheet decorative type and necessary provision for concealed type light fittings, fixed on 22 gauge GI channel grid work main joist of size 50 x 25 mm spaced at 600 mm centre, secondary joist of size 75x20 mm fixed to main joists spaced t 900 mm suspended to roof members using 25 x 25 x 2 mm GI angles and fasteners @ 1.2 m C/C including decorative design/pattern all as specified and directed Engr-in-Charge. |
| 20 | Taking down chowkats or frame with shutter ( without taking off shutter from frame) , n exc 1.5 sqm each complete all as specified. |
| 21 | Taking down chowkats or frame with shutter ( without taking off shutter from frame) exc 1.5 sqm but n exc 4 Sqm each complete all as specified. |
| 22 | M&L for taking down old aluminium partition, windows, doors etcof any description and pattern complete all as specified and as directed by Engr-in-Charge. |
| 23 | M&L in repairs powder coated Aluminium frame and shutter for doors, sliding windows & ventilators (moveable louvers type) and for prtitions with one or more rebates including joining cleat for fixing etc. Rubber gasketing all round the panels/ shutters to fix glass, PVC gasketing in all channels, locking arrangement, (minimum thickness of powder coating 50micron) complete all as specified. |
| 24 | S & F in repairs of 5 mm thick glass sheet, one side frosted, ordinary quality, glazing in squares not exceeding 0.50 sqm in each pane, fixed to aluminium windows/ventilators with rubber beading, complete all as specified and as directed by Engineer-in-Charge. |
| 25 | S & F in repairs of 5 mm thick glass sheet, one side frosted, ordinary quality, glazing in squares exceeding 0.50 sqm in each pane, fixed to aluminium windows/ventilators with rubber beading, complete all as specified and as directed by Engineer-in-Charge. |
| 26 | S & F in repairs of aluminium anodized grill, (Deco Grill DG-103, 7.5 mm thick of M/s Elesar Focchi Ltd. or equivalent), fixed with suitable ‘F’ section (No. 8584, size 15.30 × 23.40 × 1.40 mm), fabricated and riveted to aluminium windows, complete all as specified and as directed by Engineer-in-Charge. |
| 27 | S & F in repairs of 12 mm thick pre-laminated medium density fibre board (MDF), both sides decorative laminated, interior grade, fixed in aluminium or wooden framework, complete all as specified and as directed by Engineer-in-Charge. |
| 28 | Taking down cement plaster or cement lime plaster on brick or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc complete and ubbish off the premises outside the MD land (The place of disposal shall be find out by contractor). all as specified. |
| 29 | M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth (with out using extra cement) including Sagol finish including irrection and dismantling of scaffolding to carrying out works up to 1 to 4 storeys buildings complete. |
| 30 | M & L for applying one coat of Hydrolock waterproofing compound by brush, without dilution, over the finished surface, complete all as specified and as directed by Engineer-in-Charge. |
| 31 | M & L for rendering 10 mm thick cement mortar in CM (1:3) on ceilings (ceiling height measured up to the top slab of the building), including erection and dismantling of scaffolding for carrying out work up to mezzanine floor level, complete all as specified and as directed by Engineer-in-Charge. |
| 32 | M & L rendering 15 mm thick in CM (1:4) on external surface of wall incl WPC @ 3% by weight of cement including irrection and dismantling of scaffolding to carrying out works up to 1 to 4 storeys buildings complete. |
| 33 | Supply only waterproofing compound, @ 3% by weight of cement, complete all as specified and as directed by Engineer-in-Charge. |
| 34 | M & L for preparation of new plastered wall surfaces of any description and applying two coats of acrylic (antifungal) exterior grade paint @ 1.67 litres/10 sqm, including one coat of primer @ 2.20 kg/10 sqm, on walls/roofs of buildings up to 1 to 4 storeys, complete all as specified and as directed by Engineer-in-Charge. |
| 35 | M & L for preparation of new plastered wall surfaces and applying two coats of oil bound distemper over one coat of alkali-resistant primer and 3 mm thick wall care putty, complete all as specified and as directed by Engineer-in-Charge. |
| 36 | M & L for preparation of new plastered ceiling surfaces and applying three coats of white wash, complete all as specified and as directed by Engineer-in-Charge. |
| 37 | M & L for preparation of old wall surfaces of any description and applying one coat of acrylic (antifungal) exterior grade paint @ 1.67 litres/10 sqm, including one coat of primer @ 2.20 kg/10 sqm, on walls/roofs up to 1 to 4 storeys buildings, complete all as specified and as directed by Engineer-in-Charge. |
| 38 | M & L for preparation of old wall surfaces of any description and applying two coats of acrylic (antifungal) exterior grade paint @ 1.67 litres/10 sqm, including one coat of primer @ 2.20 kg/10 sqm, on walls/roofs up to 1 to 4 storeys buildings, complete all as specified and as directed by Engineer-in-Charge. |
| 39 | M & L for preparation of old ceiling surfaces and applying one coat of oil bound distemper, complete all as specified and as directed by Engineer-in-Charge. |
| 40 | M & L for preparation of old ceiling surfaces and applying one coat of oil bound distemper, including necessary scaffolding, complete all as specified and as directed by Engineer-in-Charge. |
| 41 | M & L for complete removal of existing treatment on wall surfaces, including surface preparation and sanding to achieve smooth finish, applying one coat of wall primer and two coats of oil bound distemper of approved shade, complete all as specified and as directed by Engineer-in-Charge. |
| 42 | Taking down PVC/ CI wastage and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, complete all as specified and as directed |
| 43 | Supply & Fixing in repairs 160mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracket suitable for 160mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 44 | S&F 160mm dia bore PVC (SWR) bends any radius complete all as specified and as directed |
| 45 | Supply & Fixing in repairs 110mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracket suitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 46 | Supply & Fixing in repairs 75 mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracket suitable for 75 mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 47 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 48 | S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 49 | S&F in repairs 100mm dia of outler cast iron nahani trap , with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed. |
| 50 | Taking up or down 15mm bore steel tubing connection including cleaning for refixing or removing etc complete. |
| 51 | Taking up or down 20mm bore steel tubing connection including cleaning for refixing or removing etc complete. |
| 52 | supply, laying, connecting and fixing GI tubing of 15 mm , medium grade, with all fittings, fixed to wall and ceiling or laid in floor, complete all as specified and as directed by Engineer-in-Charge. |
| 53 | supply, laying, connecting and fixing GI tubing of 20 mm , medium grade, with all fittings, fixed to wall and ceiling or laid in floor, complete all as specified and as directed by Engineer-in-Charge. |
| 54 | M & L for laying only GI pipes of 15 mm , medium grade, complete all as specified and as directed by Engineer-in-Charge. |
| 55 | M & L for laying only GI pipes of 20 mm , medium grade, complete all as specified and as directed by Engineer-in-Charge. |
| 56 | S&F of vitreous china urinal, half stall type complete including providing and fixing plugs bedding urinal against wall in cement mortar in 1:2 securing urinals to plugs with and including 60 mm brass screws, pointing around urinal back in cement , fixing with flush pipes, inlet ,outlet etc complete all as specified and directed as fixed in repairs. |
| 57 | S&F for vitreous china urinals, bowl type (back or corner wall type,) complete including providing and fixing plugs bedding urinal against wall in cement mortar in 1:2 securing urinals to plugs with and including 60 mm long brass screws, pointing around urinal back in cement , flush pipes, inlet ,outlet etc complete all as specified and directed as fixed in repairs. |
| 58 | S&F in repairs 32mm dia PVC waste pipe for WHB and urinals fixed in repairs complete all as specified and directed. |
| 59 | S&F in repairs fancy type bib taps, chromium plated cast copper alloy 15mm bore with crutch or butter fly handle, screwed down, & fixed complete all as specified and as directed |
| 60 | S&F fixed in repairs Wash hand basin vitreous china (flat back) size 550 x 400 mm including brackets for fixing purpose, waste brass chromium plated with long screwed shanks and fly nuts 32 mm size including bottle trap complete all as specified and directed. |
| 61 | S&F in repairs fancy type pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed in repairs of 15 mm bore pipe etc complete all as specified and directed. |
| 62 | S&F vitreous china water closet (Squatting pan) “Orissa” pattern of size 580 x 440 mm white with integral foot rest and ‘P’ trap (excluding flushing cistern) but including PVC flush pipe and provision of lime concrete bedding as fixed in repairs complete all as specified and directed. |
| 63 | S&F vitreous china wash down water closet pan (Pedestal pattern), white (excluding flushing cistern and flush pipe) fixed as in repairs complete all as specified and directed. |
| 64 | S&F in repair for seat cover for pedestal pan with plastic water closet seat , black or white, closed pattern with flat bottom and cover amnd mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 65 | S & F in repairs for 10 litre capacity PVC valveless syphonic action type flushing cistern high or low level (exclusive of brackets) white with inlet ball valve, float and handle inlcuidng brackets complete all as specified and directed. |
| 66 | S&F brass Chromiun Plated towel rail, 20mm dia, D type , 60 cm long between flanges fixed in repairs complete all as specified. |
| 67 | S&F toilet paper holder of viterous china box type white coloured fixed to walls withchromium plated brass screws CP brass fixed to walls etc, fixed in repairs complete all as specified and directed. |
| 68 | S & F in repairs of brass chromium plated (CP) shower rose of 125 mm size, complete all as specified and as directed by Engineer-in-Charge. |
| 69 | S&F in repairs sinks with drainage bard made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwar wall or including fxing cantilever brackets and connecting uinon to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed |
| 70 | S & F in repairs for providing 15 mm dia PVC connection of length 450mm long complete all as specified and directed. |
| 71 | M&L 600x450 mm beveled edge looking mirror 5 mm thick selected quality glass mounted on 6 mm thick AC building board fixed to wall by wooden plug with chromium plated brass screw and cup washer fixed as in repair complete all as specified and directed. |
| 72 | Taking down shutters of any description exc 1 Sqm but nexc 2 sqm complete all as specified and directed. |
| 73 | S&F Ist class hard wood glazed and skelton shutter 30 mm thick window shutters divided into squares with plain chamfered or rounded mitred and rebated sash bars with edges of shas bars and frame moulded, fitted with out and mitred beeds for screwing glass/guage etc size of members of shutters as specified in SSR Part-I Section 8.20 (b) all as specified and directed. |
| 74 | S&F 35mm thick second class hard wood, plain framed, panelled shutter of 9mm BWP comercial ply or 12mm veneered particle board with comercial veneering on both faces the size of rail land stile as per IS 1003 (Part-I) killn seasoned and chemically pressure treated . |
| 75 | S&F Ist class hard wood plain solid, straight, chowkats and frames wrought framed rebated on the solid , rounded or chamfered put together with glue pinned at joints. |
| 76 | S & F of mild steel flat iron 25 × 3 mm, such as holdfasts and other similar small articles, conforming to grade Fe 410-O or Fe 310-O, complete all as specified and as directed by Engineer-in-Charge. |
| 77 | S & F of 100 mm butt hinges, mild steel, with mild steel hinge pin, bright polished and fixed, type B-11, complete all as specified and as directed by Engineer-in-Charge. |
| 78 | S & F of 75 mm butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11, complete all as specified and as directed by Engineer-in-Charge. |
| 79 | S & F of 200 mm long aluminium anodized barrel tower bolts of extruded sections, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. |
| 80 | S & F of 150 mm long aluminium anodized barrel tower bolts of extruded sections, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. |
| 81 | S & F of 300 mm long aluminium alloy, anodized sliding door bolts, with hasp & staple (bolt type), including fixing clips of sheet steel, extruded sections, fixing bolts and sliding bolts of extruded section or cast aluminium alloy, complete all as specified and as directed by Engineer-in-Charge. |
| 82 | S & F in repairs of 300 mm long aluminium alloy, anodized sliding door bolts, with hasp & staple (bolt type), including fixing clips of sheet steel, extruded sections, fixing bolts and sliding bolts of extruded section or cast aluminium alloy, complete all as specified and as directed by Engineer-in-Charge. |
| 83 | S & F of 140 mm long floor door stopper, of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor, complete all as specified and as directed by Engineer-in-Charge. |
| 84 | S & F of 150 mm extruded aluminium alloy handles, cast type, fixed complete all as specified and as directed by Engineer-in-Charge. |
| 85 | S & F in repairs of 150 mm extruded aluminium alloy handles, cast type, complete all as specified and as directed by Engineer-in-Charge. |
| 86 | S & F of 100 mm extruded aluminium alloy handles, cast type, fixed complete all as specified and as directed by Engineer-in-Charge. |
| 87 | S & F in repairs of 100 mm extruded aluminium alloy handles, cast type, complete all as specified and as directed by Engineer-in-Charge. |
| 88 | M & L for preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 89 | S&F solid PVC door frame of size 50mmx 47mm made out of 5mm wood grains printed PVC sheet reinforced with ms square tube and edges painted to match with printed sheet complete all as specified. |
| 90 | S&F factory made solid panel PVC door shutter 30 mm thick (styled) consisting of frame made out of MS tube for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC ,C\\" channel having a PVC sheet strip of 20mm width stuck in side with salvent cemet for stiles and plain colour PVC sheet for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet bedding and jointed together with solvent cement suppling and fixing in the frame at site all as specified and directed. |
| 91 | S & F of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm, complete all as specified and as directed by Engineer-in-Charge. |
| 92 | S & F in repairs of 4 mm thick bakelite sheet, with decorative laminate on both sides, complete all as specified and as directed by Engineer-in-Charge. |
| 93 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 94 | M & L for framed steel work, such as grills, gratings, sunshades, etc., with ends of bars shouldered and/or riveted or welded, or forged into spikes, including framed guard bars, barred iron doors, ladders, balustrades, walkways, railings, framework of water tanks and similar works, conforming to grade Fe 410-O or Fe 310-O, complete all as specified and as directed by Engineer-in-Charge. |
| 95 | S & F of rolled mild steel sections, grade Fe 410-W (E-250), quality-A, in plates (plain or chequered), channels, etc., such as in manhole covers, square cut or notched, including forming holes (ordinary and countersunk), without any attachment, complete all as specified and as directed by Engineer-in-Charge. |
| 96 | M & L for roof trusses (framed), trussed purlins, crane gantries, rails and fastenings, and heavy bracket framing (beams, tees, angles, channels or flat sections), including distance pieces, cleats, etc., complete all as specified and as directed by Engineer-in-Charge. |
| 97 | M & L for steel work in tubular trusses, including special shaped washers, etc., using ERW or induction butt welded tubes conforming to IS 1161:1979, grade St-240, complete all as specified and as directed by Engineer-in-Charge. |
| 98 | M&L for preparing new or previously untreated surface of steel of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 99 | M&L for preparation of old steel surfaces exc 10 cm width or girth and applying one coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed. |
| 100 | S & F expanded metal, weight nexc 4.00 Kg per sqm bent to shape required and tying with and including annealed mild steel wire not less than 0.90mm dia or fixing with galvanised steel staples suplied and fixed complete to wood or steel members, complete all as specifed. |
| 101 | Demolition of stone/brick masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings dressed stone work and pre cast concrete articles complete all as specified and directed. |
| 102 | M&L brickwork with sub class 'B' bricks , straight or curved on plan exc 6m mean raidus built in cement mortar 1:6 complete all as specified and directed |
| 103 | Material & labour as fixed in repairs for Stainless steel decorative railings, staircase (design and pattern as approved) made out of SS pipes, SS flats, SS plates etc. of grade 316 complete with and including necessary welding, buffing/ polishing and fixing complete all as specified and directed by Engineer-in-Charge. Design for stairs/ladders or any others will be as approved by GE. |
| 104 | M & L in repairs for stainless steel decorative railing chains, of alloy grade 316, having minimum 8 mm thickness (design and pattern as approved), used to connect two stainless steel posts with hooks, etc., including necessary welding, buffing/polishing and fixing, complete all as specified and as directed by Engineer-in-Charge. |
| 105 | Cleaning of sewage lines/manholes/open drains of any size, shape and depth, by removing waste and sludge manually or mechanically, including taking all necessary precautions as per rules in vogue, and disposing of sludge and surplus soil to a distance outside MD land, complete all as specified and as directed by Engineer-in-Charge. |
| 106 | M & L for waterproofing treatment to sunken floors/walls, by applying two coats of waterproofing chemical mixed with cement in the ratio 1:1.5 (Pidicrete URP or equivalent approved), including PCC 1:7:12, type F2, using 40 mm graded aggregate as filling, complete all as per manufacturer’s instructions and as directed by Engineer-in-Charge. |
| 107 | M & L for Erection and dismantling of MS tubular double scaffolding (H-frames) up to 30 m height, including necessary bracing, provision of safety equipment for workers, and covering with green cloth up to top of scaffolding for carrying out external face work of walls, complete all as specified and as directed by Engineer-in-Charge. |
| 108 | M&L for double action floor spring hydraulically regulated made up of minium 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as per manufacturer's instruction. |
| 109 | S & F of solar control film, 25 micron, reflective type, fixed to glass panes as per manufacturer’s instructions, complete all as specified and as directed by Engineer-in-Charge. |
| 110 | S & F of push type taps for urinals, cast copper alloy, with crutch or butterfly handle, screwed down, suitable for 15 mm dia iron pipe or brass ferrule, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. |
| 111 | S & F in repairs of health faucet (jet), with 1 m long PVC tube, wall hook, chromium plated, fitted to 15 mm bore stopcock, complete all as specified and as directed by Engineer-in-Charge. |
| 112 | M & L for toughened glass, 10 mm thick, as in hinged doors, partitions, automatic doors and similar works, including cutting to shape and drilling holes as required, complete all as specified and as directed by Engineer-in-Charge. |
| 113 | Dismantling plain or corrugated steel sheeting, any gauge or thickness incl Nainital or similar pattern roof coverings all as specified and directed. |
| 114 | S&F pre-painted hot- dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. |
| 115 | S&F pre-painted hot- dip aluminium-zinc alloy metallic coated plain steel sheet, corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. |
| 116 | M & L for 100 mm dia cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) diameter of outlet in 100 mm all as specified and as directed. |
| 117 | M & L for 75 mm dia cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) diameter of outlet in 75 mm all as specified and as directed. |
| 118 | M & L for 1.5 mm thick galvanised steel sheet as in facia of roof, window chajja and Valley gutters fixed with rivets or other suitable arrangements over MS brackets in any shape/design as required profile with desired slope, including cutting holes, make design etc complete all as specified and as directed by Engr-in-Charge. |
| 119 | M & L for Complete removal of existing water proofing treatment incl PCC of any thickness & description in any position including cleaning, wire brushing, watering, as directed by Engineer-in-charge complete all as specififed and as directed. |
| 120 | M&L for PCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in roof/chajja padding for maintining roof/chajja slope complete all as specified and as directed by EIC. |
| 121 | Disconnecting existing water tanks, any capacity of tank setting aside (or lowering if required) for repair etc and hoisting reconnecting and refixing in position complete all as directed by Engr in Charge. |
| 122 | M & L for brushing neat cement slurry, using 3.0 kg of cement per sqm on cleaned and washed concrete surfaces, complete all as specified and as directed by Engineer-in-Charge. |
| 123 | M & L for providing waterproofing treatment with 4 mm thick APP (Atactic Polypropylene) modified bituminous membrane, reinforced with non-woven polyester mat of minimum 180 gsm, laid by thermo-fusion using LPG torch after applying bituminous primer @ 0.25 kg/sqm, including overlaps (100 mm at ends and 75 mm at sides), and providing non-woven geotextile fabric of 150 gsm over the membrane, complete all as specified and as directed by Engineer-in-Charge.Note: Membrane shall be taken up to 800 mm height in walls by cutting grooves and finished with proper flashing. |
| 124 | S & F of bevelled edge mirror of selected quality glass, fixed on 6 mm thick asbestos cement (AC) board or commercial plywood backing, including mirror brackets, complete all as specified and as directed by Engineer-in-Charge. |
| 125 | S & F in repairs of roller ventilation blinds, made out of standard cloth of approved texture, including all necessary accessories, complete all as specified and as directed by Engineer-in-Charge. |
| 126 | M & L for solid PVC wall lining/panelling of solid or hollow type, as required, using 5 mm thick plain colour PVC sheets, including solvent cement and fixing on PVC frame, complete all as per specifications, drawings and as directed by Engineer-in-Charge. |
| 127 | M & L for 5 mm thick PVC sheet fillets, 35 mm width, for wall panelling, including fixing to wall to form PVC framework, complete all as per specifications, drawings and as directed by Engineer-in-Charge. |
| 128 | M&L for Preparation of floor PCC, interlocking tiles, chequered tiles, any floor tiles over a one coat of Glossy floor paint (indigo paints) on floor surfaces of any description and applying one coat of indigo paints all as specified and directed. |
| 129 | M & L for preparation of old/new concrete surfaces, including wire brushing, cleaning with gunny bags, brooming, watering and filling cracks with PU concrete, complete all as specified and as directed by Engineer-in-Charge. |
| 130 | M & L for applying one coat of polyurethane primer on old/new concrete floor surfaces, complete all as specified and as directed by Engineer-in-Charge. |
| 131 | Providing and applying of Polyurethane coating of any colour, offer excellent durability, abrasion resistance, and chemical resistance. They provide a protective and seamless finish, enhancing the aesthetics of concrete floors while offering resistance to wear, stains, and environmental factors, making them suitable for various applications all as specified and directed by Engineer in Charge. |
| 132 | Removing debris exc. 1.50 Km but n exc. 20 Km and depositing where directed, in soil outside MD land. |
| 133 | Demolition of plain cement concrete of any description and in any position not other wise specifically provided for. |
| 134 | M & L for providing and applying microconcrete, of approved make (Fosroc/Dr. Fixit or equivalent), for repairs to dock walls, jetties, corners, grooves, steps, piers and similar marine structures, including taking down damaged concrete, thorough cleaning of surfaces, application of epoxy bonding agent (Nitobond or equivalent), shuttering if required, and placing microconcrete in position including all lifts, complete all as per site conditions and as specified and as directed by Engineer-in-Charge. |
| 135 | M & L for repair to RCC members (columns, beams, walls, chajjas, etc.) by taking down, chipping and removing loose/spalled/damaged concrete and mortar, exposing reinforcement, cleaning reinforcement by wire brushing, applying rust remover and washing, providing additional reinforcement as required (measured separately), applying two coats of epoxy zinc primer on steel, applying polymer modified bond coat on prepared concrete surfaces, and finishing with ready-mix polymer modified plaster, complete all as specified and as directed by Engineer-in-Charge.Note: New reinforcement and MS sections shall be measured and paid separately. |
| 136 | M & L for repair to RCC members (columns, beams, walls, chajjas, etc.) by taking down, chipping and removing loose/spalled/damaged concrete and mortar, exposing reinforcement, cleaning reinforcement by wire brushing, applying rust remover and washing, providing additional reinforcement as required (measured separately), applying two coats of epoxy zinc primer on steel, applying polymer modified bond coat on prepared concrete surfaces, and finally providing and placing microconcrete and finishing the surface, complete all as specified and as directed by Engineer-in-Charge.Note: New reinforcement, MS sections and microconcrete shall be measured and paid separately. |
| 137 | Supply only ready-mix microconcrete, of approved make (Dr. Fixit/Sunanda/Chemestik/Fosroc), complete all as specified and as directed by Engineer-in-Charge. |
| 138 | Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for. |
| 139 | M & L Precast RCC (1:2:4) type BI using 20mm graded crushed stone aggregate as in cover slabs and set incement mortar 1:4, complete all as specified. (Reinforcement shall be measured and paid separately all as directed by Engineer-in-Charge. |
| 140 | M & L for Formwork to sides and soffits of beams, floor or roof beams, haunchings, girders, bressummers, lintels, cantilevers, shelves/slabs, including supports, overhangs, etc., and splays between floors and beams, with rough finished surface of concrete, complete all as specified and as directed by Engineer-in-Charge. |
| 141 | M & L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal, complete all as specified and as directed by Engineer-in-Charge. |
| 142 | M&L for complete removal of existing treatment on wall surfaces and applying a coat of wall care putty 1mm thick on plastered surfaces, preparatory to distemparing and applying two coats of oil bond distemper over a coat of wall primer all as specified and directed. |
| 143 | M&L for rendering 5mm thick in CM 1:3 on fair faces of brick work or concrete surfaces in ceiling finishing the surface even smooth all as specified and directed. |
| 144 | M&L for preparation of newly plastered surfaces in ceiling, applying three coats of white wash all as specified and directed. |
| 145 | Dismantling of timber scantlings, 40 sq cm and over in section, in any position in unframed work, complete all as specified and as directed by Engineer-in-Charge. |
| 146 | Supply and fix in repairs anchor bolt fasteners of size 300mm long and 25mm dia including drilling holes in timber, as required and directed by Engineer in charge.Note: In case of non availability of required length and dia of fastener bolt, next higher size as available in market will be used for work without any extra price . |
| 147 | M & L for Core cutting with mechanical instrument on RCC jetties slabs, corner, stone boulder on jetty corner/jetty wall etc shape min 200mm long and 25mm to 30mm dia including filling with epoxy hardener all as specified and as directed by Engineer in Charge. |
| 148 | M&L for preparation of new decorated wooden surfaces of any description over 10 cm width or girth, applying two coat of synthetic enamel paint over a coat of primer all as specified and directed. |
| 149 | M&L for complete removal of existing plastered wall surface, over 10cm girth preparation of surfaces, applying two coats of 100% acrylic, weather resistant emulsion over a coat of exterior wall primer complete all as specified and as per manufacturer's instruction. |
| 150 | M&L for preparation of old painted surfaces of wood or wood based surfaces over 10 cms width or girth and applying one finishing coat of synthetic enamel paint on wooden surfaces complete all as specified and directed. |
| 151 | M&L for preparation of RCC/PCC roof structure and priming @ 0.8 Kg per Sqm of finished concrete surface complete and an evenly a coat of cold bituminous at 1 Kg per Sqm and applying seating cloth over cold bituminous , finaly paving bitumen of any penetration at 2.5Kg per Sqm all as specified and as directed. |
| 152 | Removing excavated material & debris exc. 1.50 Km but n exc. 15 Km and depositing where directed, in soil. |
| 153 | M&L 10mm dia over mild steel TMT (CRS) bars, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engr-in-charge. |
| 154 | -ditto- all as per item 153 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 155 | Supply and fix structural steel framed works such as angle, channel, grating, gate, ladder etc. Confirming to Fe-290, E-165 as in supporting structure of duct, drain edge etc including making good the disturbed portion of concrete surfaces with 1:2:4 type B0 (using 12.5mm graded stone aggregate) all as specified and directed. |
| 156 | M & L for cleaning of stone/concrete surfaces in jetties, docks, retaining walls, piers and bottom portions of deck slabs above sea level, using mechanical grinding and controlled water jet/misting with fine nozzle system, including removal of all marine vegetation, complete all as specified and as directed by Engineer-in-Charge.Note: Rate shall be inclusive of scaffolding or any alternative safe access arrangement and necessary safety measures at site. |
| 157 | M & L for applying anti-carbonation coating, one coat of Dekguard S (Fosroc or equivalent) over one coat of approved primer (Dekguard or equivalent) on vertical concrete surfaces of jetty/dry dock above sea level, complete all as specified and as directed by Engineer-in-Charge.Note: Rate shall be inclusive of scaffolding or any alternative safe access arrangement and necessary safety measures at site. |
| 158 | M & L for applying anti-carbonation coating, two coats of Dekguard S (Fosroc or equivalent) over one coat of approved primer (Dekguard or equivalent) on vertical concrete surfaces of jetty/dry dock above sea level, complete all as specified and as directed by Engineer-in-Charge.Note: Rate shall be inclusive of scaffolding or any alternative safe access arrangement and necessary safety measures at site. |
| 159 | M & L for raking out existing pointing or any hard material and carrying out repointing/repairs to damaged stone masonry in jetty/dock above sea water level, using Rendroc SP 40 (Fosroc) or equivalent approved material suitable for marine environment, including finishing to neat lines using proper tools, complete all as specified and as directed by Engineer-in-Charge. |
| 160 | M&L for Preparation of floor PCC, interlocking tiles, chequered tiles, any floor tiles over a Two coat of indigo paints all as specified and directed. |
| 161 | M & L for applying 2 mm thick thermoplastic paint for lettering, numerals, lines, dashes, arrows, etc., complete all as per manufacturer’s instructions and as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail