| 1 | Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and fittings complete and making good the disturbed surfaces complete all as specified and as directed. |
| 2 | M&L for point wiring for one light/fan/bell with single core PVC insulated and unsheathed stranded FRLSH copper conductor cable 1100 volts grade size 1.5 Sqmm (nominal area) in and including PVC conduit & PVC casing capping 20/25/32/40 mm width with one single core PVC insulated unsheathed 1.5 Sqmm (nominal area) stranded FRLS copper conductor as earth continuity wire and connected to earth dolly including PVC switch board on existing wall surface for one light/fan point /bell point controlled by one number one way switch & making good the disturbed surface to match with existing surface/wall complete all as specified and as directed. Note: - (i) Rate quoted shall include provision of blank plates as per site requirement (No extra payment will be made for the same) |
| 3 | All as per Item No 2 here-in-before but for one 5 pin socket outlet 5 Amps on independent board with 1.5 Sqmm size complete all as specified and as directed. |
| 4 | All as per Item No 2 here-in-before but One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size complete all as specified and as directed. |
| 5 | All as per Item No. 2 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 4 Sqmm copper cable FRLSH & 4 Sqmm FRLSH copper cable for earth continuity wire complete all as specified and as directed. |
| 6 | S&F for switch piano flush type 6 Amp single pole one way complete all as specified and as directed. |
| 7 | S&F for socket flush type 6 Amp 5 Pin complete complete all as specified and as directed. |
| 8 | S&F for switch socket combination 5 Pin 6 Amp universal complete all as specified and as directed. |
| 9 | S&F for switch socket combination 5 Pin, 6/15 Amp universal complete all as specified and as directed. |
| 10 | S & F ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and as directed. |
| 11 | S & F call bell, ding dong AC 230 volts, single pole complete all as specified and as directed. |
| 12 | S & F bell push, flush type, 5 amp complete all as specified and and directed. |
| 13 | S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all complete and as directed |
| 14 | S&F sub main wiring with 2 run of 4.0 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLSH working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC conduit & casing/caping (20/25/32/40 mm width) including size 4.0 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB\\"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface complete all as specified and as directed. ( NOTE :- Two runs of 4.0 Sqmm pvc wire, one run of 4.0 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit |
| 15 | S&F sub main wiring with 2 run of 6.0 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLSH working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC conduit & casing/caping (20/25/32/40 mm width) including size 6.0 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB\\"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface complete all as specified and as directed. ( NOTE :- Two runs of 6.0 Sqmm pvc wire, one run of 6.0 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit |
| 16 | Supply and fixing circuit/ sub main wiring with two run of single core 10 Sqmm PVC insulated unsheathed stranded cable (FRLSH) copper conductor drawn through PVC casing caping with all fittings including 10 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC casing caping and including PVC casing caping all as specified and as directed.Note : (i) Two run of single core cable 10 sq mm and one run earth wire 10 sq mm will be measured as one length |
| 17 | S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. |
| 18 | S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. |
| 19 | S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 12 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. |
| 20 | S&F VTPN distribution board with provision of MCCB as incommer, double door suitable for mounting MCB's/Isolators, 415 Volt,4 way with built in 160A rated bus bar and with out MCCB complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. Note: Incoming cable to VTPN DB to be clamped to wall incl. necessary conduit and streamlined. Also any kind of dismantling of sheet metal enclosure accompanied by brickwork to make good disturbed surfaces is deemed to be included in quoted price. |
| 21 | S & F MCCB, 4P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 16KA complete all as specified and as directed. |
| 22 | S & F MCB, SP, 240V, 40 Amps and ' B ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed. |
| 23 | S & F MCB, SP, 240V, 6 to 32 Amps and ' C ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed. |
| 24 | S & F MCB, SPN, 240 V, 40 to 63A Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked , all as specified and as directed. |
| 25 | Supply and fix ceiling fan regulator electronic Step type, solid state, 120W, 2 module, 240 volts, complete all as specified and as directed. |
| 26 | S & F MCB TPN 415 V 16 to 32 A and 'C' curve series of breaking capacity 10 kA ISI marked, complete all as specified and as directed. |
| 27 | S & F MCB TPN 415 V 40 to 100 A and 'C' curve series of breaking capacity 10 kA ISI marked, complete all as specified and as directed. |
| 28 | S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush of 240v mounting enclosure with 2 pin earth plug socket complete all as directed . |
| 29 | S&F in repair for wall mounted LED 4 feet 20 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 30 | S&F in repair for wall mounted LED 2 feet 10 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 31 | S & F conical/globe shaped post top lantern LED type 40 Watt 230 V AC outdoor type with decorative top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete incl. fittings viz. tube bends, tubes, etc to mount complete all as specified and as directed. |
| 32 | Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 33 | Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 34 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 35 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x 6mm thick burried in ground (earth pit not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 m below normal ground level, connected to earth lead wire 4.0mm dia as earthing lead by means of bolts, nuts, check nuts, and washers of GI or steel, GI wire protected by 20 mm bore medium grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 40 mm bore light grade GI, wire mesh charcoal or coke common salt laid in altrnative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC(1:3:6) type C-1, 50 mm thick pre-cast RCC(1:2:4) type B-1 normally mix cover slab reinforced with in 8 mm dia TMT bar 10 cm C/C both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft/loose/hard soil and disposal of soil to a distance n.exc 50 m and necessry testing on completion all as shown in electrical plate No 3 MES schedule part-I complete all as specified and as directed. |
| 36 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 8 mm galvanised iron or steel wire,complete all as specified and as directed. |
| 37 | Supply and fixing Switch modular type, single pole, one way, 5/6 Amp, one module, completes all as specified and directed. |
| 38 | Supply and fixing socket outlet multipurpose having provision for 6 A-2/3 pin combined, two module complete all as specified. |
| 39 | Supply and fixing Switch modular type, single pole, one way, and 15/16 Amps, one module complete all as specified. |
| 40 | Supply and fixing socket outlet multipurpose having provision for 6/16 Amp-2/3 pin, combined 2 module completes all as specified and directed. |
| 41 | S&F White cover plate with frame,1 module complete all as specified and as directed. |
| 42 | S&F White cover plate with frame,2 module complete all as specified and as directed. |
| 43 | S&F White cover plate with frame,3 module complete all as specified and as directed. |
| 44 | S&F White cover plate with frame,6 module complete all as specified and as directed. |
| 45 | S&F White cover plate with frame,8 module complete all as specified and as directed. |
| 46 | S&F White cover plate with frame,4 module complete all as specified and as directed. |
| 47 | S&F Metal flush box 1 module complete all as specified and as directed. |
| 48 | S&F Metal flush box 2 module complete all as specified and as directed. |
| 49 | S&F Metal flush box 3 module complete all as specified and as directed. |
| 50 | S&F Metal flush box 6 module complete all as specified and as directed. |
| 51 | S&F Metal flush box 8 module complete all as specified and as directed. |
| 52 | S&F Metal flush box 4 module complete all as specified and as directed. |
| 53 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, unarmoured, electric power cables (heavy duty) 1100 Volts grade with stranded/solid copper conductor of size 16 sq mm 4.0 core conforming to IS:7098 incl. accessories to install cable viz. copper lugs, cleat/hangers/clamps, cable tier, etc. at places required complete all as specified and as directed. |
| 54 | S & F Gong Bell single phase-220/250 V AC, size-9\\" with Aluminium Cast Body, Dust & Weather Proof & Chromium mild-steel pressed gong, to be mounted on wall complete all as specified and directed. Make-Kheraj GB-22 or equivalent as specified. |
| 55 | S & F rechargeable emergency LED bulbs 15 W, 230 V AC, cool white colour with minimum 04 hours backup, automatic battery charging, overcharge & deep discharge protection alongwith 4 kV surge protection to endure power fluctuations incl. integral driver, complete all as specified and as directed. Please Enable Macros to View BoQ information |