| 1 | S & F in replacement Pressure die cast aluminum alloy housing LED street light fitting 90 Watt comprises of pressure die cast Aluminium housing & having system efficiency 110 lumens/Watt. All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 5KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto 440 v for 8 hr,IP66 Protected,THD<10%,CRI>70CCT 5700+/-300K, PF>0.9, Driver efficiency>85%,LM79 report require from NABL Accediated lab all as directed by Engr-in-Charge. |
| 2 | S&F in replacement Nature Switch street light controller three phase 5 KW of automatic street light switch using infrared sensor based NATURAL SWITCH for automatic switching of street lights, required illuminance for switching on is ≤30 Lux and for switching off ≥10 Lux also having part night operation 4 to12 hour with contactors and outgoing and incoming MCBs connected with min 10sqmm FLRS multistranded circuit all these must be enclosed in a pole/wall mounted enclosure made of rust proof, electric shock proof and termite proof conforming to IP54 complete all as specified and directed by engineer in charge. |
| 3 | Material and labour for painting to existing LT steel tubular poles of sizes 9 mtr including bracket and other accessories as per site requitrement after preparing/ scraping the metal surface with emery sheet in all respect for making smooth surface and painted with one coat coat of aluminium paint and upto 1.5 mtr height from pedestral in 30 cm height in black and white paints complete all as per site requirement complete all as specified as directed. |
| 4 | M&L for painting of LT poles 9 mtr with synthetic enamel paint upto 2 mtr height with black and white paints with two coats and painting of cross arm/channel/clamp and street light bracket with aluminium paint incl making good to receive the paint incl base paint strips with synthetic enamel paint of approved colour all as shown & directed. |
| 5 | S and F in replacement polycarbonate junction loop in / loop out box of internal size 250 x 200 x 100 mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 5/6 Amps MCB-01 No, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular pole using 25 x 3mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and as directed. Note: Make :- HENSEL / SINTEX / HANSU |
| 6 | S&F in replacement service bracket for street light fitting made out of 40 mm bore light grade GI pipe of length 1.5 mtr long (approx) bend to shape 115 degree and fix to pole for fixing of street light fitting on pole/wall etc fixed with 2 Nos 32x 6 mm GI clamp, Nut,bolts,washer etc complete all as specified and directed. |
| 7 | Supply and fix single core copper conductor PVC insulated unsheathed FR 1100 Volt grade 1.5 Sqmm size,multistranded unsheathed including connection from kiosk box to street/flood/garden light fittings complete all as specified and as directed. Make : Polycab/Havells/Anchor |
| 8 | Supply and fix Heavy duty PVC Non metallic conduit of external dia 20 mm on street light poles/ bollard lights/high mast lights including binding of conduit pipe at minimum two places at equi-distance with GI wire with the pole complete all as specified and directed at site. |
| 9 | Supply, install and test All in One Integrated Solar LED Street light 60 W with LED>150 LPW with IP-65 protection, compact design including 6 m octagonal pole suitable for the above solar street light with all accessories, microwave based motion sensor for optimising battery autonomy with factory setting dimming profile along with microwave sensor for run time maximization. Solar Panels with Lithium Ferro phosphate battery withh inbuilt BMS technology, MPPT charge controller with serviceable battery compartment. Cat Part No. CSOP-841-60-57-HL5-PIR-LM-PG Crompton or equivalent of Havells/Philips. Rate quoted deemed to include earth work, PCC and coping. |
| 10 | Supply & Fix LED flood light ftg 150 Watts , Incl Driver unit assy with surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected Driver efficiency>85%,LM79 report require from NABL Accediated lab all as directed by Engr-in-Charge. |
| 11 | Taking down Street lights, solar street lights, Hight mast light fitted on poles/buildings at height up to 10-20 mtr from ground level and repairing the same and refixing with proper connections complete all as per the instruction of JE E&M / Engineer in Charge.Note: - (i) Cost of spares and accessories will be measured and paid seperately under relevent items. (ii) Cost for soldering of panel shall be deemed to be included in the unit rate quoted. |
| 12 | Supply only LED driver unit suitable for 60 watt LED Fitting complete all as specified and directed at site. |
| 13 | Supply only LED driver unit suitable for 90 watt LED Fitting complete all as specified and directed at site. |
| 14 | Supply only LED driver unit suitable for 120/150 watt LED Fitting complete all as specified and directed at site. |
| 15 | Supply only PCB kit suitable for LED All-in-One solar light Fitting complete as per existing sample all as specified and directed at site. |
| 16 | Supply & Fixing in replacement LED post top lamps of minimum capacity 25 W used for gate light IP 65 spun aluminium landcape luminiare opal cover including fixing of GI pipe all as specified and directed by Engr-in-Charge. |
| 17 | Supply & Fixing in replacement round gate post top lamp crafted with durable plastic and a robust rust resistant B22 holder with IP65 water resistance technology including LED bulb all as specified and directed by Engr-in-Charge. |
| 18 | Supply and fix in replacement garden light IP-65 rated 10 W with soft 360 degree light distribution Crompton cat part No. LBLSN-10-CDL complete all as specified and directed at site. Make : Crompton/Havells/Philips |
| 19 | M&L in replacement Steel tubular swaged poles complete with cast iron base plate,finial taper plug,bolts,nuts & screws as specified type 410 SP-31 ( 9.00 Meters long) including earth work and PCC complete including shifting of street light, junction box, cable, channels, conductor connections from old pole to new pole all as specified and directed by Engr-in-Charge. Note : Any materials replaced will be measured in individual items respectively. |
| 20 | M&L for repair to high mast of height up to 13 to 16 mtr servicing of light carrying winch and gear box alongwith SWR rope complete with replacing the minor parts like nut bolts, SWR rope and connected items all as specified and directed. |
| 21 | M&L for trenchless boring under road crossings/foot paths by manual / Boring machine complete all as specified and directed at site. |
| 22 | M&L in replacement of XLPE cable 4 core 25 sqmm insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 Volts grade, in trenches/fixed on wall all as directed by Engineer-in-Charge.Note: (i) Rate include the cost of lugs of proper size and cable gland (ii) Necessary Excavation, bricks and sand for cable protection shall be measured & paid separately. |
| 23 | M&L in replacement of XLPE cable 4 core 16 sqmm insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 Volts grade, in trenches/fixed on wall all as directed by Engineer-in-Charge.Note: (i) Rate include the cost of lugs of proper size and cable gland (ii) Necessary Excavation, bricks and sand for cable protection shall be measured & paid separately. |
| 24 | Supply and fix in replacement of 50 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc all as specified and directed at site. |
| 25 | Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable including sand punning complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments. |
| 26 | Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed. |
| 27 | Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed. |
| 28 | Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 29 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 Please Enable Macros to View BoQ information |