| 1 | Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and fittings complete and making good the disturbed complete all as specified and as directed. |
| 2 | M&L for point wiring for one light/fan/bell with single core PVC insulated and unsheathed stranded FRLS copper conductor cable 1100 volts grade size 1.5 Sqmm (nominal area) in and including PVC conduit & PVC casing capping 20/25/32/40 mm width with one single core PVC insulated unsheathed 1.5 Sqmm (nominal area) stranded FRLS copper conductor as earth continuity wire and connected to earth dolly including PVC switch board on existing wall surface for one light/fan point /bell point controlled by one number one way switch & making good the disturbed surface to match with existing surface/wall complete all as specified and as directed. Note: - (i) Rate quoted shall include provision of blank plates as per site requirement (No extra payment will be made for the same) |
| 3 | All as per Item No 2 here-in-before but for one 5 pin socket outlet 5 Amps on independent board with 1.5 Sqmm complete all as specified and as directed. |
| 4 | All as per Item No 2 here-in-before but One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size complete all as specified and as directed. |
| 5 | All as per Item No. 2 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 4 Sqmm copper cable FRLS & 4 Sqmm FRLS copper cable for earth continuity wire complete all as specified and as directed. |
| 6 | S&F for switch piano flush type 6 Amp single pole one way complete all as specified and as directed. |
| 7 | S&F for socket flush type 6 Amp 5 Pin complete complete all as specified and as directed. |
| 8 | S&F for switch socket combination 5 Pin 6 Amp universal complete all as specified and as directed. |
| 9 | S&F for switch socket combination 5 Pin, 6/15 Amp universal complete all as specified and as directed. |
| 10 | S & F ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and as directed. |
| 11 | S & F call bell, ding dong AC 230 volts, single pole complete all as specified and as directed. |
| 12 | S & F bell push, flush type, 5 amp complete all as specified and and directed. |
| 13 | S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all complete and as directed |
| 14 | S&F sub main wiring with 2 run of 4.0 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC conduit & casing/caping (20/25/32/40 mm width) including size 4.0 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB\\"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface complete all as specified and as directed. ( NOTE :- Two runs of 4.0 Sqmm pvc wire, one run of 4.0 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit |
| 15 | S&F sub main wiring with 2 run of 6.0 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC conduit & casing/caping (20/25/32/40 mm width) including size 6.0 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB\\"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface complete all as specified and as directed. ( NOTE :- Two runs of 6.0 Sqmm pvc wire, one run of 6.0 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit |
| 16 | S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. |
| 17 | S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. |
| 18 | S&F VTPN distribution board with provision of MCCB as incommer, double door suitable for mounting MCB's/Isolators, 415 Volt,4 way with built in 160A rated bus bar and with out MCCB complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. |
| 19 | S & F MCCB, 4P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 16KA complete all as specified and as directed. |
| 20 | S & F MCB, SP, 240V, 40 Amps and ' B ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed. |
| 21 | S & F MCB, SP, 240V, 6 to 32 Amps and ' C ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed. |
| 22 | S & F MCB, SPN, 240 V, 40 to 63A Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked , all as specified and as directed. |
| 23 | Supply and fix ceiling fan regulator electronic Step type, solid state, 120W, 2 module, 240 volts, complete all as specified and as directed. |
| 24 | S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush of 240v mounting enclosure with 2 pin earth plug socket complete all as directed. |
| 25 | S&F in repair for wall mounted LED 4 feet 20 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 26 | S&F in repair for wall mounted LED 2 feet 10 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 27 | Dismantling complete ceiling fan (of size 1200/1400/1500 mm sweep-single phase IM or BLDC based) alongwith down rod, canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out stator, motor winding, ball bearings, gun metal bush, PCB etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufractures design and directed and re-assembling (b) New spare parts (i.e) rubber bush of shackle and condenser housing, gun metal bushes, ball bearing, shaft, PCB, twin twisted copper cable shall be measured and paid separately under relevant item. However, cost of AC connector/DC connector for BLDC ceiling fans shall deemed to be included in the quoted price of current serial. |
| 28 | Supply and fixing ceiling fan shackle kit complete with fan rod nut-bolts, hook nut-bolts in rubber bushing and lock pin suitable for ceiling fan 1200/1400 mm sweep complete all as specified and as directed. |
| 29 | Supply and fixing bearing number of 6201/6202/6203/6204 as required,complete all as specified and as directed. Make : SKF/NBC or Equivalent make as specified. |
| 30 | Supply and fixing condenser 2.5 Mfd complete all as specified and as directed. |
| 31 | Supply and fixing condenser 3.15 Mfd complete all as specified and as directed. |
| 32 | Supply and fixing PVC holder for condenser housing complete all as specified and as directed. |
| 33 | Supply and fixing twin core twisted copper flexible wire/cable of size 0.5 sqmm, single core complete all as specified and as directed. |
| 34 | Supply and fixing only gun metal bush complete all as specified and as directed. |
| 35 | Supply and Fix MS ceiling fan shaft suitable for 1200/1400/1500 mm sweep fans, complete all as specified and as directed. |
| 36 | Supply & Fix BLDC Ceiling Fan (1200 mm/1400mm sweep) microcontroller based PCB compatible upto 18 Pole Stator, 90–305V AC Input Voltage with advanced protection features viz. overcurrent, short circuit, and surge protection up to 6kV, Power Rating-28 W to 35 W incl. PCB casing, complete all as specified and directed. |
| 37 | S & F BLDC Ceiling Fan Rotor Magnet Ring upto 18 Pole suitable for Sweep Size 1200 mm to 1400 mm, complete all as specified and directed. |
| 38 | Taking down ceiling fan/exhaust fan and complete painting of ceiling fan by scraping with brush / removing old spray paint with the help of paint remover chemical and spray painting with two coat of synthetic enamelled paint with super glossy finish (grey/brown/white) with the help of spray painting machine and writing Ceiling fan Nos with paint and refixing the same as complete all as specified and as directed. |
| 39 | Dismantling complete exhaust fan of size 350/400/450 mm sweep or pedestal fan with condenser housing unscrewing the body parts of ehaust fan, taking out stator, motor winding, ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufractures design and directed and re-assembling (b)New spare parts (i.e) condenser housing, gun metal bushes, ball bearing, shaft twin twisted copper cable shall be measured and paid separately under relevant item. |
| 40 | Supply and Fix exhaust fan shaft suitable for 300/380/450 mm sweep fans or shaft suitable for pedestal fan , complete all as specified and directed. |
| 41 | Supply and fixing flapper shutter, louvers of exhaust fan 300/380/450 mm sizes made out of powder coated metal body of appropriate thickness. Fixing of exhaust fan louvers should be done with the help of anchor, fastener, nut bolts Complete all as specified and as directed. |
| 42 | Supply and fix exhaust fan motor AC single Phase, 230V for size 300 mm, upto 50 W sweep exhaust complete all as specified and as directed. |
| 43 | Supply and fix exhaust fan motor AC single Phase. 230V for size 380 mm sweep , upto 100 watt exhaus complete all as specified and as directed. |
| 44 | Supply and fix exhaust fan motor AC single Phase. 230V for size 450 mm sweep , upto 150 watts exhaust complete all as specified and as directed. |
| 45 | Supply and fixing exhaust fan frame with holding legs complete incl. suitable nuts/bolts for exhaust fan of 300/380/450 mm sweep as per existing make/size complete all as specified and as directed. |
| 46 | Supply & fixing blade made of iron suitable for Exhaust fan 300 mm sweep complete all as specified and as directed. |
| 47 | Supply & fixing blade made of iron suitable for Exhaust fan 380 mm sweep complete all as specified and as directed. |
| 48 | Supply & fixing blade made of iron suitable for Exhaust fan 450 mm sweep complete all as specified and as directed . |
| 49 | Dismantling/Disconnecing of electric and water connection of the geyser, taking down from its position on ground, dismantling geyser complete viz removing tank from its outer body, geyser assembly plate from the tank, descaling geyser inner tank and apparatus plate using descaling chemical complete, electrically testing its thermostate & heating element and testing tank for leakage, reassembling the geyser, replacement of unserviceable parts such as heating element, thermostate, indication lamp, plug top, three core cable, rubber gasket, inner tank, split plate, outer bottom cover, apparatus plate if required (Spares will be paid under relevant item of the Schedule), testing the geyser and installation of the geyser into its original position and connecting all electric and water supply connection complete all as specified and as directed of capacity 25/50 litres. |
| 50 | Supply & fix indication lamp (green / red) as required complete all as specified and as directed. |
| 51 | Supply and replacement thermostat for geyser as per site requirement temp setting on 60 degree Centigrade ISI Mark complete all as specified and directed. |
| 52 | Supply and replacement heating element any type as per site requirement of capacity 2 KW ISI Mark complete all as specified and directed. |
| 53 | Supply& fix inner Stainless Steel tank 304 grade of cap 25 ltr all complete all as specified |
| 54 | Supply and replacement Apparatus plate 06/09 hole for 25/50 litres capacity geyser made out of brass and chromium plated as per site requirement complete all as directed. |
| 55 | Supply and replace glass wool for 25/50 ltrs capacity geyser complete all as specified and directed. |
| 56 | Supply and replacement Auto-cut Switch for geyser as per site requirement ISI Mark complete all as specified and directed. |
| 57 | S&F 3 core PVC insulated, PVC round cable of size 4 sqmm with stranded copper conductor complete all as specified and directed. |
| 58 | Supply & Fixing PRCD plugtop 16 A, 30 mA, 230 V, 50 Hz AC conforming to IEC:61540, equipped with an auto trip feature which shuts off if detects any current leakage complete all as specified and directed. |
| 59 | Supply& fix PCB universal type suitable for 25 / 35 Ltr Geyser all complete all as specified |
| 60 | S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed of size not less than 450mm long for cold water complete all as specified and as directed. |
| 61 | S&F hot water pipe for geyser of size not less than 450 mm, connection with check nuts and washers complete all as specified and as directed. |
| 62 | S&F in replacement of gun metal non return valve of 15mm dia, 0.8 Mpa ISI marked complete all as specified and as directed. |
| 63 | Supply & fixing 15mm dia `medium grade', galvanised iron steel tube with all necessary fittings fixed to wall and ceiling or laid in floor complete all as specified and as directed. |
| 64 | S & F 15 mm Chromium plated, fancy type, Stop valves, cast copper alloy screwed down, high presure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 65 | S & F 15mm chromium plated bib taps, fancy type, cast copper alloyed with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed . |
| 66 | S&F fastner geyser hanging hook with nuts and bolts complete to hang properly and bear the water filled geyser weight all as specified and directed. |
| 67 | M&L for flameproof Light/fan point wiring complete with 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including stove enamelled steel conduit not less than 20 mm dia including all accessories viz. saddle, elbow, tee, steel flexible pipe, etc. fixed on Walls / Roofs / Floors / Ceiling etc. including 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Link complete all as specified.Note: Point Wiring to be connected to light/ Fan terminal through flexible Flameproof conduit. |
| 68 | All as per Item No. 67 here-in-before but for one 3 pin socket outlet, 15 Amps on independent flameproof board with 4.0 Sqmm FRLSH cable complete all as specified and as directed. |
| 69 | S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole, flameproof as per IS/IEC:60079-1:2014 and weather proof as per IS/IEC 60529:2001 (reaffirmed 2014) all complete as specified and as directed. |
| 70 | All as per Item No. 69 here-in-before but double pole, complete all as specified and as directed. |
| 71 | S&F Switch flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250 V, 2P+Earth, flame proof as per IS/IEC:60079-1:2014 and weather proof as per IS/IEC 60529:2001 (reaffirmed 2014) all complete |
| 72 | S&F in repair LED light fitting 2x16/20 Watt (4') flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size flame proof as per IS/IEC:60079-1:2014 and weather proof as per IS/IEC 60529:2001 (reaffirmed 2014),all as specified and as directed. |
| 73 | All as per Item No. 72 here-in-before but 1 x 8/10 Watt (2'), complete all as specified and as directed. |
| 74 | All as per Item No. 72 here-in-before but 1 x 16/20 Watt (4'), complete all as specified and as directed. |
| 75 | S&F in repair Exhaust Fan of 18\\" size, 230 V Single Phase AC with Enclosure-Flame Proof (Ex-d), Gas Group IIA, IIB, IIC as per IS/IEC 60079-1:2014 and weatherproof conforming to IP-65 as per IS/IEC 60529:2001 (Reaffirmed 2014) , Area Classification- Ex db IIC T6 Gb ( Ex tb / tc IIC T85 C Db/Dc ( Zone 1 & 2 & Zone 21 & 22)), CIMFR Certified, Temperature Class T6, Aluminium Blade (Non Sparking), Epoxy Powder Coated Shade complete with all accessories all as specified and directed. (Make: Sudhir/FCG or equivalent make as specified ) Note: Core cutting into or through brickwork/masonary works/cement concrete wall (any description) and covering with brickwork for already core cutting in place is deemed to be included in the quoted price. |
| 76 | S&F in repair flameproof ceiling fan of 48\\" size sweep, 230 V Single Phase AC with Enclosure-Flame Proof (Ex-d), Gas Group IIA, IIB, IIC as per IS/IEC 60079-1:2014 and weatherproof conforming to IP-65 as per IS/IEC 60529:2001 (Reaffirmed 2014) , Area Classification- Ex db IIC T6 Gb ( Ex tb / tc IIC T85 C Db/Dc ( Zone 1 & 2 & Zone 21 & 22)), CIMFR Certified, diecast aluminium alloy materia, M.S powder coated blade material, epoxy powder coated finish, class F insulation incl gland & plug complete with all accessories all as specified and directed. (Make: Sudhir/FCG or equivalent as specified ) |
| 77 | S&F in repair flameproof ceiling fan regulator 500 W, 230 V Single Phase AC in LM6 with cable termination box in LM6 flameproof as per IS/IEC:60079-1:2014 and weather proof as per IS/IEC 60529:2001 (reaffirmed 2014) all complete as specified and as directed. (Make: Sudhir/FCG or equivalent make as specified ) |
| 78 | S&F in repair flameproof Light Distribution Box 415 V with 01 No. incomer (63 A 4P MCB) and 06 No. outgoing (06 Nos. 16 A SP) with Enclosure-Flame Proof (Ex-d), Gas Group IIA, IIB, IIC as per IS/IEC 60079-1:2014 and weatherproof conforming to IP-65 as per IS/IEC 60529:2001 (Reaffirmed 2014) , Area Classification- Ex db IIC T6 Gb ( Ex tb / tc IIC T85 C Db/Dc ( Zone 1 & 2 & Zone 21 & 22)), CIMFR Certified, Temperature Class T6, diecast aluminium alloy material, epoxy powder coated shade as per IS:5, incl brass gland & plug & earthing complete with all accessories all as specified and directed. (Make: Sudhir/FCG or equivalent make as specified ) |
| 79 | S & F in repair flameproof flood light fitting 70 W LED, 220 V AC alongwith surge protection with Enclosure-Flame Proof (Ex-d), Gas Group IIA, IIB, IIC as per IS/IEC 60079-1:2014 and weatherproof conforming to IP-65 as per IS/IEC 60529:2001 (Reaffirmed 2014) , Area Classification- Ex db IIC T6 Gb ( Ex tb / tc IIC T85 C Db/Dc ( Zone 1 & 2 & Zone 21 & 22)), CIMFR Certified, Temperature Class T6, diecast aluminium alloy material, epoxy powder coated shade as per IS:5, heat resistant clear type-A toughened glass incl brass gland & plug & earthing complete with driver and necessary structure for mounting complete with all accessories all as specified and directed. |
| 80 | S & F in repair DOL Starter,3 hp, single phse, 230 V AC with Enclosure-Flame Proof (Ex-d), Gas Group IIA, IIB, IIC as per IS/IEC 60079-1:2007 and weatherproof conforming to IP-65 as per IS/IEC 60529:2001, Area Classification- Ex db IIC T6 Gb ( Ex tb / tc IIC T85 C Db/Dc ( Zone 1 & 2 & Zone 21 & 22)), CIMFR Certified, Temperature Class T6, diecast aluminium alloy material, epoxy powder coated shade as per IS:5, gland & plug & earthing complete with driver and necessary structure for mounting complete with all accessories all as specified and directed. |
| 81 | Unmounting of existing VTPN DB after disconnecting all cables & MCB/MCCB from site and shifting to location as directed and remounting the same at the new location incl. all the accessories required for re-mounting viz nut-bolts, clamps, etc and reconnecting MCCB/ MCB alongwith necessary cable connections, complete all as specified and directed . Please Enable Macros to View BoQ information |