| 1 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of Cable/pipe and getting out in soft loose soil complete all as specified and as directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed. |
| 3 | Description all as per Item No-1 above but depth exceeding 1.5 mtr and not exceeding 3 mtr complete for pole foundation complete all as specified and as directed. |
| 4 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 5 | Material and labour PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path and for chain link fencing etc complete all as specified and as directed. |
| 6 | Material and labour PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and as directed. |
| 7 | Material and labour for stone dust for cousioning of UG cable/ at cable trenches /inside substation bulding etc complete all as specified and as directed. |
| 8 | Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm complete all as specified and as directed. |
| 9 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & 14930 (Part-I and II) for protection of underground cable of size 40mm outer dia with all fittings such as clamps, coupler etc. laid in trenches/roads/nallah or fixed along wall/ poles or laid under floor (including cutting floor/road and making to match with existing adjouning surface etc. for cable protection all as specified and as directed. (excavatoin and earth work measured and paid separately) |
| 10 | Description all as per item No. 9 above but of size 50mm outer dia. |
| 11 | Description all as per item No. 9 above but of size 63mm outer dia. |
| 12 | Labour for Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismantling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit complete all as specified and as directed. |
| 13 | Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty XLPE UG cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 core with required aluminium cable lugs complete all as specified and as directed. |
| 14 | Description as per item No. 13 above but 10sqmm 2 core |
| 15 | Description as per item No. 13 above but 16sqmm 2 core |
| 16 | Description as per item No. 13 above but 10sqmm 4 core |
| 17 | Description as per item No. 13 above but 16sqmm 4 core |
| 18 | Description as per item No. 13 above but 25sqmm 3,5 core |
| 19 | Description as per item No. 13 above but 35 sqmm 3.5 core |
| 20 | Description as per item No. 13 above but 50sqmm 3.5 core |
| 21 | Description as per item No. 13 above but 70sqmm 3.5 core |
| 22 | Description as per item No. 13 above but 95sqmm 3.5 core |
| 23 | Description as per item No. 13 above but 120sqmm 3.5 core |
| 24 | Description as per item No. 13 above but 185sqmm 3.5 core |
| 25 | Description as per item No. 13 abovee but 240 sqmm 3.5 core |
| 26 | Labour for dismantling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and keeping aside for refixing or carrying to store for credit complete all as specified and as directed. |
| 27 | Material and labour for steel tubular swaged pole complete with cast iron base plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long). complete all as specified and as directed. |
| 28 | Dismantling and taking down old/unsv cross arms, bracing, supports etc complete for reuse at site or carrying to store for sch of credit complete all as specified and as directed. |
| 29 | Material and labour cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and as directed. |
| 30 | Dismantling and taking down old/unsv ACSR conductor any size complete all as specified and as directed. |
| 31 | Material and labour for replaceing old ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection complete all as specified and as directed. |
| 32 | Taking down old/unsv insulator of any type any size from pole/stay complete all as specified and as directed. |
| 33 | Material and labour pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade all as specified and as directed. |
| 34 | Material and labour shackle type, porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and as directed. |
| 35 | Material and labour loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm complete all as specified and as directed. |
| 36 | Material and labour for stay assy using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismantling unsv one all as specified and as directed. (Clamps, loop insulator, earth work, PCC measured separately) |
| 37 | Material and labour for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding incl dismantling taking down unserviceable one complete all as specified and as directed. |
| 38 | Material and labour for cradle hexagonal /rectangular fabricated with galvanised steel wire not less than 4mm dia on pole incl dismantling taking out unsv cradle guard complete all as specified and as directed. |
| 39 | Supply and fix earth continuity wire using GI wire not less than 4mm dia on pole incl dismantling taking out unsv GI wire complete all as specified and as directed. |
| 40 | Material and labour for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion all as specified and as directed. |
| 41 | Material and labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr belo ground level connected to galvanized iron strip of size 32x6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earh work GI pipe 20 mm dia medium grade for watering PCC chamber with PCC cover in cement concreate 1:2:4 Type B1 (20 mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc connected to panel board/ Gen set as indicated including testing complete all as specified and as directed. NOTE :- Earth protection pipe & earthing strip upto and including 7.5 m lenth is deemed included in unit rate quoted by the contractor. |
| 42 | Material and labour for restraining of overhead ACSR conductor of any size of 4 wire 35-45 met span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and directed . |
| 43 | Material and labour for restraining of ACSR conductor of any size of 2 wire 35-45 met span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and as directed. |
| 44 | Material and labour for restraining of GI Cradle guard hexagonal/rectangular of any size 35-45 met span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and as directed. |
| 45 | Material and labour for restraining of GI earth wire of any size 35-45 met span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and as directed. |
| 46 | Cutting/Trimming of tree branches arround 3.00 met distance from conductors of HT over head line of span up to 50 meters including removing of creepers etc fron poles all as specified and as directed. |
| 47 | Cutting/Trimming of tree branches arround 3.00 met distance from conductors of LT over head line of span up to 40 meters including removing of creepers/vegitation etc fron poles all as specified and as directed. |
| 48 | Material and labour heat shrink end joint indoor/outdoor LT 1100 volts grade 10-16 sqmm, 4 core, make-Raychem, Cat No-EPKT0003 or equivelent of M-Seal/3M all as specified and as directed. |
| 49 | Material and labour heat shrink end joint indoor/outdoor LT 1100 volts grade 25-50 sqmm, 3.5 core, make-Raychem, Cat No-EPKT0019 or equivelent of M-Seal/3M all as specified and as directed. |
| 50 | Material and labour heat shrink end joint indoor/outdoor LT 1100 volts grade 70-150 sqmm, 3.5core, make-Raychem, Cat No-EPKT0035 or equivelent of M-Seal/3M all as specified and as directed. |
| 51 | Material and labour heat shrink end joint indoor/outdoor LT 1100 volts grade 185-300 sqmm, 3.5 core, make-Raychem, Cat No-EPKT0051 or equivelent of M-Seal/3M all as specified and as directed. |
| 52 | Material and labour heat shrink straight through joint out door type LT 1100 volts grade 10-16 sqmm, 4 core, make-Raychem, Cat No-EPKJ0123 or equivelent of M-Seal/3M all as specified and as directed. |
| 53 | Material and labour heat shrink straight through joint outdoor type LT 1100 volts grade 25-50 sqmm, 3.5 core, make-Raychem, Cat No-EPKJ0130 or equivelent of M-Seal/3M all as specified and as directed. |
| 54 | Material and labour heat shrink straight through joint outdoor type LT 1100 volts grade 70-150 sqmm, 3.5 core, make-Raychem, Cat No-EPKJ0137 or equivelent of M-Seal/3M all as specified and as directed. |
| 55 | Material and labour heat shrink straight through joint outdoor type LT 1100 volts grade 185-300 sqmm, 3.5 core, make-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/3M all as specified and as directed. |
| 56 | Material and labour for Painting of steel pole any type up to 7.5 mtr height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation all as specified and as directed. |
| 57 | Material and labour for numbering of HT/LT poles serially with letter/number size width and height up to 40 mm in site with white paint on black back ground all as specified and as directed. |
| 58 | Material and labour GI tubing light grade 40mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection including taking out old pipes all as specified and as directed. |
| 59 | Material and labour GI tubing light grade 50mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection, ISI marked, for cable protection including taking out old pipes all as specified and as directed. |
| 60 | Material and labour GI tubing light grade 80mm bore,on pole /wall with necessary clamps, nuts, bolts and washers/under road cross ISI marked, for cable protection ISI marked, for cable protection including taking out old pipes all as specified and directed. |
| 61 | Material and labour GI tubing light grade 100mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection ISI marked, for cable protection including taking out old pipes all as specified and directed. |
| 62 | Material and labour for jumper connections of length up to 1.50 met with existing size and guage of ACSR, binding with existing conductors for LT OH lines all as specified and as directed. |
| 63 | Material and labour for danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 1100 volts, 20 x 15 cm size including taking out defective danger boards all as specified and as directed. |
| 64 | Material and labour for danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 11000 volts, 25 x 20 cm size including taking out old danger boards all as specified and as directed. |
| 65 | Supply and errect cast Iron HT/LT cable route indicator round shaped 120 mm dia 8 mm thick duly embossed with MES HT/LT Cable fixed on flat iron 25X3 mm thick 300 mm long and grouted in PCC (PCC measured separately) all as specified and as directed. |
| 66 | Material and labour for rigid PVC line spacer, U-shaped, spriral type, suitable for 2 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade all as specified and as directed. |
| 67 | Material and labour for rigid PVC line spacer, U-shaped, spriral type, suitable for 4 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade all as specified and as directed. |
| 68 | Material and labour for aluminium cable lugs of size 50 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints |
| 69 | Material and labour for aluminium cable lugs suitable for XLPE cable size 70 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point all as specified and as directed.NOTE :- To be measured only, fixed at places other than with heat shrink joints. |
| 70 | Material and labour for aluminium cable lugs suitable for XLPE cable size 95 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point all as specified and as directed.NOTE :- To be measured only, fixed at places other than with heat shrink joints. |
| 71 | Material and labour for aluminium cable lugs suitable for XLPE cable size 120 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints. |
| 72 | Material and labour for aluminium cable lugs suitable for XLPE cable size 150 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints. |
| 73 | Material and labour for aluminium cable lugs suitable for XLPE cable size 240 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints. |
| 74 | Material and labour for aluminium cable lugs suitable for XLPE cable size 300 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point all as specified and as directed. NOTE :- To be measured only, fixed at places other than with heat shrink joints. |
| 75 | Material and labour for MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 400 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 76 | Material and labour for replaceing MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 350 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 77 | Material and labour for Replaceing MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 78 | Material and labour for replaceing MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 250 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 79 | Material and labour for replaceing MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 160 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 80 | Material and labour for replaceing MCCB, 3 pole, 35 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 81 | Material and labour for replaceing MCCB, 3 pole, 35 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 350 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 82 | Material and labour for replaceing MCCB, 3 pole, 35 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 160 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 83 | Material and labour for replaceing MCCB, 3 pole, 16 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 125 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 84 | Material and labour for replaceing MCCB, 3 pole, 16 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 100 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 85 | Material and labour for replaceing MCCB, 3 pole, 16 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 63 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 86 | Material and labour for replaceing MCCB, 3 pole, 16 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 40 amps, incl dismantling taking down unsv one, complete all as specified and as directed. |
| 87 | Material and labour for replaceing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10 sqmm and overall PVC sheathed in service connections from OH conductor to building incl dismantling taking down unserviceable one all as specified and as directed. |
| 88 | Description as per item No. 87 above but size of cable 6 sqmm |
| 89 | Description as per item No. 87 above but size of cable 4 sqmm Please Enable Macros to View BoQ information |
| 90 | Description as per item No. 87 above but size of cable 4 sqmm Please Enable Macros to View BoQ information |