| 1 | Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed by EIC. |
| 2 | Taking down carefully unserviceable sub main wiring of any size and type including making good the disturbed surfaces of walls, ceilings etc including two coats of white /colour washing/ distempering etc to match the existing complete all as directed by EIC. |
| 3 | Taking down carefully unserviceable distribution boards/metal enclosures of any type and capacity including wooden board and making good the disturbed surfaces of walls, ceilings etc including two coats of white/colour washing/ distempering etc to match the existing complete all as directed by EIC. |
| 4 | Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators complete all as specified and directed. |
| 5 | M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for One light point / one bell point controlled by one, one way switch. |
| 6 | All asper Item No.05 above but One fan point and bell point controlled by one, one way switch. |
| 7 | All asper Item No.05above but one light point controlled by 2 way switch. |
| 8 | All asper Item No.05 above but for One 3 pin, 05 /06 Amps socket outlet point on same board controlled by one , one way 05/06 Amps switch |
| 9 | All asper Item No.05 above but for One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch |
| 10 | All asper Item No.05 above but for One 3/5 pin, 15/16 Amps socket outlet point on independent board controlled by one , one way 15/16 Amps switch |
| 11 | All asper Item No.05 above but capping cassing wiring One Light/fan point/Bell point controlled by one, one way switch. |
| 12 | All as per Item No.05 above but capping cassing wiring for One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch |
| 13 | All as per Item No.05 above but capping cassing wiring for One 5 pin, 15 /06 Amps socket outlet point on independent board controlled by one , one way 15/16 Amps switch |
| 14 | Supply & fixing in repair modular switch 06 Amps 1 module complete all as specified & directed |
| 15 | Supply & fixing in repair modular switch2 way , 06 Amps 1 module complete all as specified & directed |
| 16 | Supply & fixing in repair bell push modular type 6 Amps complete all as specified & directed. |
| 17 | S & F in repair modular socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed. |
| 18 | Supply & fixing in repair modular switch 16 Amps 1 module complete all as specified & directed |
| 19 | S & F in repair modular socket 06/16 Amps 2/3 pin combined 2 module complete all as specified & directed. |
| 20 | S & F in repair electronic fan regulator modular type, 2 module, 120W including complete all as specified and directed. |
| 21 | S & F in repair switch piano flush type, 05/06 Amps single pole, one way 240 volts in replacement of old u/s complete all as specified & directed |
| 22 | Supply & fixing in repair of socket outlet 3 pin, 05/06 Amps (2-in-1 Multipurpose) flush type 240 volts in replacement of old u/s complete all as specified & directed. |
| 23 | Supply & fixing in repair of socket outlet 3 pin, 15/16 Amps (2 -in-1 Multipurpose) flush type 240 volts in replacement of old u/s complete all as specified & directed. |
| 24 | Supply & fixing in repair switch piano flush type, 15 /16 Amps single ploe, one way 240 volts in replacement of old u/s complete all as specified & directed |
| 25 | Supply & fixing in repair of ceiling rose surface three terminals in replacement of old u/s complete all as specified & directed. |
| 26 | Supply & fixing in repair bell push flush type 5 Amps in replacement of old u/s complete all as specified & directed. |
| 27 | S & F in repair Door bell AC, 230 volts, single pole in replacement of old u/s bell/ buzzer complete. |
| 28 | Supply & fixing in repair Switch socket combination 2-in-1, 3 pin, 5 and 15 Amp flush type in replacement of old u/s complete. |
| 29 | Supply & fixing in repair Switch socket combination 2-in-1, 3 pin, 5 Amp flush type in replacement of old u/s complete. |
| 30 | S & F in repair electronic fan regulator stepped, socket type 400W including removing the switch board panel and making the provision for fixing the electronic type regulator and refixing the same complete all as specified and directed. |
| 31 | S & F in repair MCB DB SPN 4Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed. |
| 32 | S & F in repair MCB DB SPN 8Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed. |
| 33 | S & F in repair MCB DB SPN 12Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed. |
| 34 | S & F in repair MCB DB TPN 4Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed. |
| 35 | S & F in repair MCB DB vertical TPN 8Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed. |
| 36 | M & L for sub main wiring complete with four runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. |
| 37 | M & L for sub main wiring complete with four runs of 6 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 6 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. |
| 38 | M & L for sub main wiring complete with four runs of 10 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 10 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. |
| 39 | Material and labour for Cutting, chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, chills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc; and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 40 | S & F in repair MCB SPN 40 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make -Havells or equivalent |
| 41 | S & F in repair MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make -Havells or equivalent |
| 42 | S & F in repair MCB TPN 40 to 100 Amps incl making connections all as specified and directed. Make -Havells or equivalent |
| 43 | S & F in repair MCB TP 25 to 63 Amps incl making connections all as specified and directed. Make -Havells or equivalent. Make -Havells or equivalent |
| 44 | S&F in repair LED PC batten light fitting of 2 feet 10 watt, with energy efficient LED and integrated electronic driver of 10W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells |
| 45 | S&F inverter emergency LED batten 20 W which provides the uninterrupted back up of upto 3hrs during power cut,with guarantee of more lumens with 4 KV surge protection to keep the product safe in any condition ,color temperature 6500 K,brightness 2000 Lm connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells/Orient |
| 46 | S&F in repair LED PC batten light fitting of 4 feet 20 watt, with energy efficient LED and integrated electronic driver of 20W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells |
| 47 | Supply & Fix in repair linear LED T8 tubular lamp 18W with extruded aluminium/PC body and PC diffuser complete with inbuilt driver incl making necessary connections in the existing fittings to suit the LED tube complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells) |
| 48 | S & F in repair LED fitting of 6 watts - Square surface mounted LED flat panel down light, PDC aluminum housing and PMMA diffuser makes it a robust Luminaire alongwith 6W LED lamp complete all as specified. (Make: Bajaj /CG/Philips/Havells |
| 49 | Supply and fixing new LED lamp 9 watt complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 50 | Supply and fixing in repair LED lamp 5 watt complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 51 | S&F in repair energy saving new generation 10W LED IP65 bulkhead luminaire with opal diffuser complete with and incl 10W LED all as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 52 | Taking down ceiling fan/Exhaust fan, sealing the cable ends dismantling the fan blade kept in safe costody complete all as specified. Note: (a) Servicing and Spares will be measured and paid seperately . |
| 53 | M & L for painting of ceiling fan/ exhaust fan complete, at site with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust all as specified. |
| 54 | Hanging only ceiling fan/exhaust fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified ,and any addn/alteration /threading if required to down rod shall be done by contractor with out any extra cost. |
| 55 | Labour for servicing the ceiling / exhaust fan of any make including greasing /oiling /repairs and replacing the spares such as cater pin unserviceable / rusted bolts, split pins, rubber wheel, bearing, washers, bush all as specified and directed . |
| 56 | Supply only GM bush of ISI marked suitable for ceiling fan of size 1200 / 1400mm sweep. |
| 57 | Supply only ball bearing suitable for ceiling fan of 1200 /1400mm sweep. Make : SKF, bearing No 6202 or equivalent in NBC. |
| 58 | Replacement of old unserviceable capacitors 2.5 MFD of the fan in position as directed by Engr - in - Charge |
| 59 | Replacement of old unserviceable capacitors 4.0 MFD of the fan in position as directed by Engr - in - Charge |
| 60 | M & L for dismantling the defective exhaust fan motor by taking out the burnt copper winding, rewinding the motor with super enamelled copper winding wire of existing gauge and weight including replacement of all insulation material, \\"O\\" rings and other petty items required for making motor functional and checking the winding leak proof complete all as specified and directed. |
| 61 | M & L for dismantling the defective Ceiling fan motor by taking out the burnt copper winding, rewinding the motor with super enamelled copper winding wire of existing gauge and weight,warnishing , including replacement of all insulation material, and other petty items required for making motor functional and checking the winding leak proof complete all as specified and directed. |
| 62 | M&L for straight through joints (epoxy) heat shrinkable type for UG cable including joint kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor upto 16 Sqmm to 10 sqmm 4 core cable complete all as specified and directed. (Make : 3M /Densons). |
| 63 | All as per ser item no. 62 here-in-before but of size upto 25 to 50 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons). |
| 64 | All as per ser item no. 62 here-in-before but of size upto 70 to 150 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons). |
| 65 | All as per ser item no. 62 here-in-before but of size upto 185 to 300 sqmm x 3.5 core complete all as specified and directed. (Make : 3M /Densons). |
| 66 | M & L for Fault locating of LT UG cables by using measuring instruments and rectification of the same by using epoxy cable joints of suitable size of cables and testing the phase contuinity of the cable complete all as specified and directed. Note : Cable joint kit and Excavation/earth work shall be measured and paid seperately. |
| 67 | Taking down unsv 250 Amps MCCB and Supply & Fix MCCB TPN 415 Volts 250 Amps rating with breaking capacity of 35 kA with adjustable thermal & magnetic release complete with making all connections as per site requirement as specified and directed. (Make : Havells / L&T/ Legrand) |
| 68 | All as per ser item no.67 here-in-before but MCCB TPN 415 Volts 100 Amps, 25 kA complete with making all connections as specified and directed. (Make : Havells / L&T/ Legrand) |
| 69 | All as per ser item no.67 here-in-before but MCCB TPN 415 Volts 160 Amps, 25 kA complete with making all connections as specified and directed. (Make : Havells / L&T/ Legrand) |
| 70 | All as per ser item no.67 here-in-before but MCCB TPN 415 Volts 63 Amps, 25 kA complete with making all connections as specified and directed. (Make : Havells / L&T/ Legrand) |
| 71 | Supply and fixing four pole changeover switch disconector with advance neutral 415 volt 50 Hz 100/125 amps in sheet steel enclosure and Conforming to IS / IEC : 60947 - 3 including dismantling old one complete all as directed. Make - Havells / L & T /Legrand |
| 72 | supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 73 | M & L for painting the surface of post top poles of size 50mm dia and 3 mtr length by applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-charge. |
| 74 | M & L for Painting of steel pole/PCC pole with cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia yellow circle & marking six black & four yellow bends width 15 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable height complete all as specified and directed. |
| 75 | Excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete. |
| 76 | Returning filling including spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick complete all as specified. |
| 77 | Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified. |
| 78 | Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified. |
| 79 | Brick protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified. |
| 80 | M & L for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed. |
| 81 | All as per Srl item No 80 here in above but GI pipe of size 80 bore |
| 82 | Taking up underground unservicable cable of any size from existing trench including bricks, etc and removing of materials from work site all as directed by Engr-in-charge. |
| 83 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 10 sqmm 4 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (Make: Havells/ Polycab/Grandlay) |
| 84 | All as per Srl item No 83 here in above but size of cable 16 Sqmm 4 core |
| 85 | All as per Srl item No 83 here in above but size of cable 25 Sqmm 3.5 core |
| 86 | All as per Srl item No 83 here in above but size of cable 35 Sqmm 3.5 core |
| 87 | All as per Srl item No 83 here in above but size of cable 50 Sqmm 3.5 core |
| 88 | All as per Srl item No 83 here in above but size of cable 70 Sqmm 3.5 core |
| 89 | All as per Srl item No 83 here in above but size of cable 95 Sqmm 3.5 core |
| 90 | All as per Srl item No 83 here in above but size of cable 120 Sqmm 3.5 core |
| 91 | All as per Srl item No 83 here in above but size of cable 150 Sqmm 3.5 core |
| 92 | All as per Srl item No 83 here in above but size of cable 185 Sqmm 3.5 core |
| 93 | All as per Srl item No 83 here in above but size of cable 240 Sqmm 3.5 core |
| 94 | S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1 No. MCB 20 Amp capacity complete all as specified and as directed |
| 95 | Supply and fixing in replacement of 1100 Volts grade heavy duty cable 10 Sqmm 2 core with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulated hanger not more than 1 mtr a part including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed by Engr-in-Charge. Make : Finolex/Plaza/Kalinga/Paragon :- |
| 96 | Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for 0.4 mpa working pressure. |
| 97 | M & L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 25 x 4mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 5 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified. |
| 98 | M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground earth pit not less than 2.25 m deep below normal ground level with the top edge of earth plate at a depth of not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia as earth lead by means of bolts, nuts, check nuts and washers made out of GI and GI strip protected by 15 mm bore light grade GI pipe as well as 20 mm dia medium grade pipe 1.5 mtr fixed with funnel and wire mesh as specified and connected all as shown in electrical plate No 3 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1 : 2 : 4 type B - 1 in chamber and 40 mm thick RCC 1 : 2 : 4 type B - 1 cover slab with 6 mm dia mild steel bars at 100 mm centre to centre both ways with 6 mm dia M S hooks complete all as specified. |
| 99 | Taking down old GI wire and Material & labour for fixing of Earth continuity conductor GI wire 4 mm dia with nut bolts at joints , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles,equipments or any other indicated situation for loop earthing etc, strip fixed on with epoxy insulator of suitable size all as specified and directed by Engineer-in-Charge. |
| 100 | Material & labour for fixing of Earth continuity conductor GI strip of size 25X 4 mm with nut bolts at joints , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles,equipments or any other indicated situation for loop earthing etc, strip fixed on with epoxy insulatorof suitable size all as specified and directed by Engineer-in-Charge. |
| 101 | Taking down the u/s post top lantern from position by disconnecting the electrical connection carefully and replacement with New generation, post-top of 40 Watts, 240V, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source including making all necessary wiring, provn of suitable fitments and connecting upto control box complete all as specified and directed. Make : Bajaj /CG/Philips/Havells |
| 102 | Supply and fix in repair CELESTA LED post top made in cast aluminium with decorative opal polycarbonate di user with IP 65 protection of cap 40 watt complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 103 | S&F PVC Junction box of size 255X200X100mm inside dimension fixed on pole by means of mild steel clamps with hinged door, bolt and nuts, provn for cable entry for incoming and outgoing including MCB 2.5 amps-1 No and 4 way connector-1nos neccessary connection duly fixed with clamps on pole and including cable glands threaded type IP55/IP65 made of polymide with lock nut complete all as specified. Make : Sintex GSJB2520 or equivalent. |
| 104 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations for electric poles, filling and mass concrete complete all as specified and directed. |
| 105 | Supply and fixing of Nature switch (using infrared sensor technology )based automatic street light control panel .This panel should be suitable enough to 3 phase load of 5 KW .Nature switch operation should be based on natural light lux level .Required illuminance level for switching ON is < 60 Lux & for switching off > 10 lux .The sensor alongwith suitable power contactors and incoming outgoing MCB should be enclosed in a pole /wall mounted rust proof ,electric shock ,termite proof and FR grade SMC Enclosure conforming to IP 54 ,The circuit should also have aprovision for manual operation (i.e sensor bypass option ) .The nature switch must have 3 phase load of 5 KW (swadeep 02EC-5kW3p with 3 nos incoming outgoing MCBs of 16 -20 Amps & 3 nos contactors (single pole /2/ pole/3 pole ) of 16-20 Amps & circuit wiring (copper )10 mm2 complete all as specified and as directecd :Make : Swadeep |
| 106 | Supply and fixing of Endura Citylite Platinum, 45 W LED Street Light fittingpressure die cast aluminium housing, heat resistance toughened glass, IP-66 protection in replacement of old UNSV 70W HPSV light fittings complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 107 | Supply and fixing of Endura Cityliner Neo, 72 W LED Street Light fitting pressure die cast aluminium housing, heat resistance toughened glass, IP-66 protection in replacement of old UNSV 150W HPSV light fittings complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 108 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 109 | Taking out the u/s Street light fitting driver and S&F LED Driver unit suitable for 30 to 45 watt capaity complete all as specified and directed Make - Bajaj /CG/Philips/Havells |
| 110 | Maintenance for APFC panel Out door/indoor Type APFC panel (out door Type) 100 (8x12.5) KVAR -02No,APFC panel (out door Type) 125 (5x20,2x12.5) KVAR -01No capacitors, internal wiring,inrush current limiting coil, auxilary contactor, indicating lamps, auto-manual selector switch, MCCB ,axial flow fan and replace the unserviceable parts. The following checking will be carried out to ensure smooth and effective operation all the time all as specified and directed. (a) Checking of the control panel,power supply, fuses ,circuits etc and tighten to any loose contact. (b) Checking of the helthiness of capacitors,contactors and APFC relays. (c) Cleaning of the panel by using blower without any distrubance/damages. (Note:- Spares will be measure and paid seperately ) |
| 111 | Capacitor (MPP, Heavy duty) 440 volts with inrush current limiting coil, 20 KVAR |
| 112 | Capacitor (MPP,Heavy duty) 440 volts with inrush current limiting coil, 10/12.5 KVAR |
| 113 | Supply and fixing Capaitor duty contactor 25 KVAR |
| 114 | Supply and fixing automatic power factor relay (APFCR) 8 stage complete all as specified and directed. |
| 115 | Supply and fixing capacitor duty contactor 20 KVAR |
| 116 | Supply and fixing capacitor duty contactor 12.5 KVAR |
| 117 | Maintenance of storage type electric water heaters(Geyser) of storage capacity 25 ltrs comprising of the following tasks and all as per specified and directed by Engr-in-Charge.(a) Inspection taking down, opening (dismantling),descaling, brushing cleaning of storage tank and painting internally with one coat of proprietary bituminous compositions not liable to impart taste or or odour or otherwise contaminate the water.(a) Examine water tightness of storage tank after cleaning.(b) Carry out operation of all stop cocks,pressure reducing valves etc to ensure free movement of the working parts.(c) Replacement washers and glands of all taps and ball valves to ensure water tightness.(d) Visual examination of fusible plug to (e) Descaling of the immersion type heating element and cleaning with diluted hydrochloric acid or \\"clear pedette\\" solution and testing before refitting.(f) Replacement/repair of neon lamp/indicator lamp.(g) Replacement of the rubber/PVC gaskets to ensure water tightness..Note : (i) Attending complaint during the currency contract period on phone call and rectification with in 24 Hrs.(ii) The spares will be measured and paid seperately. |
| 118 | All as per Item No-117 above, but of 50 ltrs storage capacity. |
| 119 | Supply only new heating element suitable to existing model and make 2 KW Dual clip type/tri angle type and round type with rubber gasket suitable for geysers up to 25/50 Ltr capacity . Make: Theeta /Elteck or equivalent |
| 120 | Supply only new heating element suitable to existing model and make 1.5 KW Dual clip type/tri angle type and round type with rubber gasket suitable for geysers up to 25/50 Ltr capacity . Make: Theeta /Elteck or equivalent |
| 121 | Supply only thermostat clip type (Range 30 C to 80 C and acting at 70 C) for geysers up to 50 Lts. range 30 C to 80 C and acting at 70 C all as specified . Make: Elcon or eq |
| 122 | Supply only PVC connections up to 600 mm in length suitable to connect GI pipe 15 mm dia to hot water outlet of geyser.Make: Kohinoor or eqivalent |
| 123 | Supply only PVC connections up to 650 mm in length suitable to connect GI pipe 15 mm dia to cold water inlet of geyser.Make: Kohinoor or eqivalent |
| 124 | Supply only pressure release valves suitable for geyser up to 50 ltrs capacity |
| 125 | Supply only indicating lamps green / red suitable for geysers up to 50 Ltrs |
| 126 | Supply only HRFR PVC insulated copper flexible cable 3 core 2.5 Sqmm and PVC sheathed 1100 volts grade |
| 127 | Taking down unserviceable plug top and supply and fixing plug top 3 pin 15 amps 230 volts complete all as specified and directed. |
| 128 | M&L for arresting the leakage in inner tank of any size/make of geyser complete with brazing work and leak test, servicing etc |
| 129 | S& F Non return valve of size 1/2\\" |
| 130 | Material and labour for painting of storage type electric water heaters(Geyser) of storage capacity 25/50 ltrs painting with one coat of synthetic enamel paint ( as per exsisting colour) all as per specified and directed by Engr-in-Charge. |
| 131 | Supply and fixing in replacement digital type Ampere meter range 0 – 400/300/200 Amps, with built in selector switch including CTs with proper ratio, square type, flush mounted of size 96 mm x 96 mm including making connection with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge. |
| 132 | Supply and fixing in replacement digital type Volt meter with built in selector switch, range 0 – 500 volts, square type, flush mounted of size 96 mm x 96 mm including making connection with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge. |
| 133 | S&F Celing Fan complete with blades , down rods ,elcetrinic regulator and acessories , 230 volts, 1200 mm sweep , min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor complete all as specified and directed. |
| 134 | S&F Celing Fan complete with blades , down rods ,elcetrinic regulator and acessories , 230 volts, 1400 mm sweep , min air delivery 245 CFM with service value 6.00 BEE five star rated with brushless direct current motor complete all as specified and directed. |
| 135 | Material and labour for Cleaning and preparation of old painted surface of LT panel board complete and painting with one coat of synthetic enamel paint (exsisting colour) on surfaces of panel board all as specified and directed by Engineer-in-Charge. |
| 136 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 137 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450m sweep with, blades, and frame and louvers complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 138 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of 250 mm sweep complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 139 | Supply and fixing wall fan of single phase 230/240V of size 400 mm sweep and grouting with nut , bolts & Fastenar on the wall and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed . |
| 140 | Supply and fix electric water heater,storage type steel body with SS inner tank and heating element upto2 KW capacity 25 litre, BEE 5 Starrated complete with all accessoriessuch as safety valve, thermostate,NRV, connection piece etc. |
| 141 | Disconnection ,Supply and Fixing Air conditioning Changeover Timer Complete all as specified and directed. Note: (a) Timer should suitable for two Ac load upto 20 A. (b) Timer should available in two modes. (c) In Auto mode gap time 30 Minute, 1hr, 2hr,3 hrs, 4hrs. (d) Din channel mounting for easy installation. |
| 142 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of 300 mm sweep complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells |
| 143 | Supply and fixing IP68 LED bollard light 10Watt for garden lighting complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |