| 1 | Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | Demolition of cement Concrete of any description and in any position including any type of rooftreatment , PCC padding, lime concrete, mud etc, complete all as specified and directed. Note: All demolished material / debries will be disposed off out side the Airforce station Nal with out any extra cost to the govt. Contractor should arrange dumping site to dispose off material. |
| 3 | M&L for cutting grooves in brick wall for inserting APP membrane and other works size of grooves 75mm wide and 65mm deep and shapping horizontal face of grooves and making good with cement mortar 1:3 or PCC 1:2:4 complete all as specified and directed. |
| 4 | M&L for Cement concrete 1:2:4 type B0,(using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops, on junction of parapet, coping etc cement concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc and including brushing neat cement slurry with 3 Kg/Sqm in roofs, complete all as specified and directed. |
| 6 | M&L for Cement concrete 1:3:6 type C1, (using 20 mm graded stone aggregate) as in roof paddding, mass concrete finishing as required gradient cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 7 | M & L for APP based polymeric membrane minium weight 3 Kg/Sqm and minium 3 mm thick, reinforced with polyster non wove fabric (wt. not less than 150 gms/Sqm ) laid by torch forced application over and including a priming coat using bituminious primer @ 0.40litre/ sqm as per manufactures instruction on concrete surface complete all as specified and directed by Engineer-in-charge. |
| 8 | M&L for 15mm thick plaster in cement mortar 1:4 mixed with water proofing compound pidi proof LW @ 200ml per 50Kg cement as per manufacturers instructions on concrete surface of roof and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge (WPC shall be measured and paid separately) |
| 9 | M&L for 20 mm thick pre-cast cement concrete tiles using 1:2:4 type B0(using 12.5mmgraded stone aggregate) set jointed and pointed in Cm 1:3 over and including 15 mm thick screed bed in cm 1:6 complete all as specified and directed by Engineer-in-Charge |
| 10 | Supply only Liquid water proofing compound ISI marked complete all as specified and directed. |
| 11 | Taking up or down 15 mm dia steel tubing & connections removal to store complete all as specified and directed. |
| 12 | Taking up or down 20 mm dia steel tubing & connectionsremoval to store complete all as specified and directed. |
| 13 | S & F 15mm bore of tube medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed. |
| 14 | S & F 20mm bore of tube medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed. |
| 15 | Refixing old steel tubing 15mm bore and connections in new or old position complete all as specified and directed. |
| 16 | Refixing old steel tubing 20mm bore and connections in new or old position complete all as specified and directed. |
| 17 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, Cleaning and removing all scale and dirt from RCC / PVC tank capacity of tanks exc. 250 ltrs and up to 500 ltrs by emptying, drying, cleaning with chlorine/washing powder by scrubbing the dust with wire brush from tank by removing inlet and outlet pipe and refixing inlet and outlet pipe, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 18 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, Cleaning and removing all scale and dirt from RCC / PVC tank capacity of tanks exc. 500 ltrs and up to 1000 ltrs by emptying, drying, cleaning with chlorine/washing powder by scrubbing the dust with wire brush from tank by removing inlet and outlet pipe and refixing inlet and outlet pipe, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 19 | Dismantling water tanks any type of capacity Exc 250 but n.exc 500 liters complete all as specified and directed. |
| 20 | Dismantling water tanks any type of capacity Exc 500 but n.exc 1000 liters complete all as specified and directed. |
| 21 | S&F 500 litre capacity Rotational moulded polyethylene water storage tank, white colour, triple layers, conforming to IS, cylindrical vertical with closed top, hoisted and fixed in position complete all as specified and as directed. |
| 22 | S&F 1000 litre capacity Rotational moulded polyethylene water storage tank, white colour, triple layers, conforming to IS, cylindrical vertical with closed top, hoisted and fixed in position complete all as specified and as directed. |
| 23 | Supply and fixed 20 mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed. |
| 24 | Re- fixing only 20 mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed. |
| 25 | S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 26 | Re- fixing 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 27 | Demolition of brick work or stone masonary, built in cement mortar or cement lime mortar including all quions,arches, pillars, ec, but excluding aslar facings,dresse stone work and percast conrete articles complete all as specified and directed. |
| 28 | M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6 m mean redius, built in cement mortar 1:6 complete all as specified and directed. |
| 29 | All as per above item No 28.00 above but except bricks complete all as specified and directed. |
| 30 | M & L for half Brick wall with sub-class 'B' bricks old size straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed. |
| 31 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 32 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm bore including necessary clumping complete all as specified and directed |
| 33 | Refixing only 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including necessary clumping complete all as specified and directed |
| 34 | S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed. |
| 35 | Taking down cement plaster on brick or stone walls/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 36 | M&L for 15 mm thick rendering in cement mortar 1:4 surface to be finished even and smooth with out using extra cement complete all as specified and directed. |
| 37 | M&L Rendering 15mm thick in cement mortar 1:6 on brick work or concrete surface and finished even and smooth without using extra cement complete all as specified and directed. |
| 38 | M&L, Rendering 10mm thick in CM 1:3 over concrete surface as on ceiling finish even and smooth w/o using extra cement, complete all as specified and directed. |
| 39 | M&L for cement based wall care putty of 1mm thickness over plastered/Unplastered surface to prepare the surface even and smooth complete all as specified and directed.Note- Entire spalashes in floor shall be cleaned immediately after completion of work |
| 40 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bond distemper over a coat of alkali-resiatant priming paint on plastered surrface complete all as specified and directed. |
| 41 | M & L for three coat of white wash on new surface of ceiling including preparation complete all as specified and directed. |
| 42 | M &L for Preparing surface of new plastered surface and applying two coats of acrylic emulsion extterior paint over coat of primer, tint as approved by GE in any pettern to match existing surface. |
| 43 | S&F in repairs ArmGyp-FB ceiling snow Frost vinyl face, washable metallized polyester foil backing ,vinyl covered edges, suspended ceiling on suspension system. Panels shall be of Size 600 mm x 600 mm x 9 mm, having 7 kg/SQM, including providing Grid system for fixing ceiling tiles shall comprise of suspension system with true horizontal level, suspended on inter locking tegular “Select” system with 15mm black flanges incorporating a 4mm central reveal in black colour and a load carrying capacity of minimum 14.50 kg/m2 with birdsmouth notches metal grid of hot dipped galvanized steel sections consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 15x32 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 15mmx25mm made of 0.30 mm thick (minimum) sheet, 1200mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200mmx600 mm and secondary cross \\"T\\" of length 600 mm and size 15mmx25mm made of 0.30 m thick (minimum) sheet to be interlocked at middle of the 1200mmx600 mm panel to form grids of 600mmx600mm and wall angle of size 20mmx15mmx0.3 mm and laying false ceiling tiles of approved texture in the grid including, required fitting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85mm x 30mm x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 15 mm of all T-sections all complete for all heights as per specifications, drawings incl dismantling of old ceiling,complete all as specified and directed. |
| 44 | M & L for providing 75 mm thick PCC 1:4:8 type D-2 (using 40 mm stone agg.) in sub base of flooring complete all as specified and directed. |
| 45 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, with grey cement, pigment with 25mm thick sand filling incl dismantling and rubbish off the primises complete all as specified and directed. |
| 46 | M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed. |
| 47 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 48 | M&L for steelwork in tubular trusses, post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979, IS-4923-1997 grade Yst-310 & above, including embeding in concrete complete and all as specified and directed. |
| 49 | S&F MS plain plates, square cut, with riveted, bolted or welded attachment FE-410-W (Gde-E-250) quality complete all as specified and directed. |
| 50 | S&F mild steel screw bolts (machine made) with hexabonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n.exc 5cm long, diameter of neck in 5 to 10mm complete all as specified and directed. |
| 51 | Dismantling Asbestos cement or CGI Sheet (corrugated or semi corrugated) or galvalume aluminum GI based corrugated steel sheeting including ridge as in roof coverig complete all as specified and directed. |
| 52 | M & L for Pre- painted coloured galvalume aluminum zinc coating GI based corrugated or semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. Note:- The colour should be decided by Engineer-in-charge. |
| 53 | M & L for Pre-painted galvalume aluminum zinc coating GIaluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. Note:- The colour should be decided by Engineer-in-charge. |
| 54 | Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 55 | M & L for repair to RCC Chajjas, roof projection edges ,hanging part of chajjas, edges of chajjas, RCC Parapets under the roof / floor slabs with PCC 1:2:4 (using 12.5mm crushed graded stone agg) incl neccasary renforcement 8mm to 12mm TMT bars , form work , MS wire mesh for bounding the concrete on ground required and plaster work in CM 1:3 & periodical services to match with the existing surfaces finishing at any height of buildings etc completed all as specified and directed by Engineer-in-Charge. M&L for disconnecting from the existing location cutting off worn out aluminium cable end and Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core including taking out existing cable of any size. Please Enable Macros to View BoQ information |