| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell life guard/Polycab/ Finolex/ Anchor/apar/ Grandlay ) single core cable in surface / recessed medium class PVC conduit/ duct, with modular switch ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.), modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell life guard/Polycab/ Finolex/ Anchor/apar/ Grandlay eq. standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit. |
| 3 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Leiva /ABB Tvisha make make.) |
| 4 | Wiring for lighting circuits/ 6- 10 amp power plugwith 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell life guard/Polycab/ Finolex/ Anchor/apar/ Grandlay eq. standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.) |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell life guard/Polycab/ Finolex/ Anchor/apar/ Grandlay eq. standard make as desired by engineer incharge ), single core cable in surface/ recessed medium class PVC conduit as required. |
| 8 | (a ) 2 X6 sq. mm + 1 X 6 sq. mm earth wire |
| 9 | ( b )2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete |
| 11 | Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends. |
| 12 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 13 | Supply installation testing and commissioning of Indicator of Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena make.) |
| 14 | Sub Head-2 - Fixtures and Fittings |
| 15 | Supply installation testing and commissioning of 15 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of crompton/Helonix/Havell make / sample to be approved before installation.. |
| 16 | S/F testing and comm. Of 20 Watt 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with THD<10%.( commercial series) Helonix/ wipro/ Havell make/ eq. standard make as directed by engineer incharge. |
| 17 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, decorative ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA /orient/Crompton make ( sample to be approved before installation) |
| 18 | Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB Tivsha/schneider Livia /Havell Coral make. |
| 19 | Supplying and fixing following way, triple pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 20 | 6 way (4 + 18) way, Double door |
| 21 | S/F testing and comm. Of MCB's 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ ABB ./equivalent make as directed by engineer incharge. |
| 22 | a) 6-32 Amp SP MCB |
| 23 | b) 40-63amp DP MCB |
| 24 | Supply , laying ( partly underground/partly overhead) , testing and commissioning of PVC XLPE insulated alluminium un-armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. |
| 25 | c)16 sq.mm 2 core Please Enable Macros to View BoQ information |