| 1 | Part-A (Internal Electrification for Hut No. 01) |
| 2 | Wiring for Light point/Exhaust point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Salzer/Paramount Make) in existing surface/recessed Conduits (Excluding Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/ABB/Equivalent Make & shall be approved before execution of work. |
| 3 | Supplying and Fixing of Indicator as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/ABB/Equivalent Make & shall be approved before execution of work. |
| 4 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Salzer/Paraflex Make) |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/ABB/Equivalent Make & shall be approved before execution of work.(Including Inverter Input/Output) |
| 6 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Havells/Anchor/Eq Make) |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 8 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Polycab/Finolex/Salzer/ Paraflext Make) & shall be approved before execution of work. |
| 9 | 2x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards. |
| 10 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter Sub main in One run from Main Panel to Distribution Boards. |
| 11 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards. |
| 12 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make |
| 13 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider Make) |
| 14 | Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/ABB/Schneider Make) |
| 15 | 32Amp. |
| 16 | 40Amp. |
| 17 | 63Amp. |
| 18 | Supplying and Fixing of MCB 8-Way (4+24) horizontal typed , sheet steel, Double Door Distribution Board, TPN 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider Make) |
| 19 | Supply/Installation/Testing and Commissioning of 12W + LED Surface/Recess Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 120 lm/W with Pressure Die cast Aluminium body & Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Wipro/Bajaj/Jaquar/LT/Crompton/Surya/Equivalent Make. |
| 20 | Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Bajaj/Jaquar/LT/Crompton/Surya/Equivalent Make. as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 21 | Supply/Installation/Testing and Commissioning of upto 400mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Anchor/Polycab/Orient Make. |
| 22 | Supply/Laying of 25/32mm Dia PVC Conduit of Anchor/Ravinder/Polypack/Finolex Make with other accessories likebends,etc complete. |
| 23 | Supply/Laying of suitable size of wooden channek as per site requirement with other accessories,etc complete. |
| 24 | Supply and Fixing of single pole blanking plates on existing MCB boxes, excluding cost of Boxes. |
| 25 | Providing and fixing of bakelite hylam sheets of required size including cutting, filing with S/F screws etc. |
| 26 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required of Legrand/Panasonic/Anchor/Schneider/Equivalent Make |
| 27 | Supply/installation/testing and commissioning of CPRI-approved panel Wall/floor-mounted compartmentalized, 415 volts TPN MCCB Main Distribution panels, fabricated out of sheet steel of 16 gauge dust-protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel.The Panel is to be provided and fitted with the following adjustable-type controlling/protection switchgear devices:1. Normal Incoming125-160 Amp DP MCCB with breaking capacity of 36 KA with extended thimbles of Havells/Legrand/Siemens/ABB//LK make = 1 no200 Amp PN Bus bar Al Strips = 1 Set,Voltmeter =1 no, Ammeter = 1 no, CT coils for Am meter 300 / 5A = 1 set, phase indicators =1 set2. Generator Incomer:63 Amp Four PoleAutomatic Changeover Switch of Havells/Legrand/Siemens/ABB//LK make = 1 no.,3. Bypass Switch:100 Amp 4-Pole Bypass Switch for bypassing 10 KVA AVROutgoing.(1) 63 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB/Schinder /L&T make = 02 No for normal heating sub main(2) 40 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB/Schinder /L&T make = 02 No for Sub main lighting(3) 32 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB/Schinder /L&T make = 02 No for Sub main invertorThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to be approved by Engineer Incharge before manufacturing (Office Complex & Laboratory Building). |
| 28 | Supply/Installation/Testing & Commissioning of 10W LED Mirror Light of Havells/Philips/Wipro/Halonix/ Equivalent Make as duly fitted on walls including making of necessary Connections & sample shall be approved. |
| 29 | Supply/Laying/Testing and Commissioning of 2- Core 50 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/Eq. Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation where required and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. Please Enable Macros to View BoQ information |