| 1 | Material and labour for repair/servicing of DG Set of capacity 25 KVA to 62.5 KVA by replacement of un-serviceable spares i.e. diesel filter, lubricating oil filter, radiator hose pipe, fan belt, fuel returning/ pressure pipe, fuel and oil pressure gauge, battery terminal/ lugs nut bolts, cleaning/ repairing of fuel tank, replacement of engine oil as required at site including testing of DG sets on load to check the smooth functioning, complete all as specified and as directed Note :- (Spare parts of DG Sets shall be measured & paid separately as supply only under the respective items here in after) |
| 2 | All as per item No 1 here-in-before but for DG set of capacity 75 KVA to 100 KVA. |
| 3 | All as per item No 1 here-in-before but for DG set of capacity 250 KVA to 320 KVA . |
| 4 | Supply only fuel filter (primary & secondry) of existing model/ make suitable for DG sets of capacity 25 KVA to 62.5 KVA complete all as specified and as directed. |
| 5 | All as per item No 4 here-in-before but for DG set of capacity 75 KVA to 100 KVA. |
| 6 | All as per item No 4 here-in-before but for DG set of capacity DG Set 250 KVA to 320 KVA . |
| 7 | Supply only oil filter of existing model/ make suitable for DG sets of capacity 25 KVA to 62.5 KVA complete all as specified and as directed. |
| 8 | All as per item No 7 here-in-before but for DG set of capacity 75 KVA to 100 KVA. |
| 9 | All as per item No 7 here-in-before but for DG set of capacity 250 KVA to 320 KVA . |
| 10 | Supply only air filter of existing model/ make suitable for DG sets of capacity 25 KVA to 62.5 KVA complete all as specified and as directed. |
| 11 | All as per item No 10 here-in-before but for DG set of capacity 75 KVA to 100 KVA. |
| 12 | All as per item No 10 here-in-before but for DG set of capacity 250 KVA to 320 KVA . |
| 13 | Dismantling and removing of radiator assembly of the following DG sets of capacity 25 KVA to 62.5 KVA from the base complete stratening of defective fins of radiator including cleaning of radiator with descaling solution & replacement of rubber hose pipe and clamps, fan bearing, impellers, bushes, gasket etc complete all as specified and directed. |
| 14 | All as per item No 13 here-in-before but for DG set of capacity 75 KVA to 100 KVA. |
| 15 | All as per item No 13 here-in-before but for DG set of capacity 250 KVA to 320 KVA . |
| 16 | Material and labour for calibration of fuel injector assembly of DG sets of capacity 25 KVA to 62.5 KVA at authorised workshop including replacement of cup, barrel and plunger injector washer, nuts bolts etc complete all as specified and directed. |
| 17 | All as per item No 16 here-in-before but for DG set of capacity 75 KVA to 100 KVA. |
| 18 | All as per item No 16 here-in-before but for DG set of capacity 250 KVA to 320 KVA . |
| 19 | Material and labour for taking out FIP aassembly of DG sets of capacity 25 KVA to 62.5 KVA, transport to civil work shop / authorised service centre, repairing, servicing, calibration of fuel pump assembly including replacement of unserviceable parts such as delivery valves, plunger , O rings, spring etc and refixing on original position complete all as specified and directed. |
| 20 | All as per item No 19 here-in-before but for DG set of capacity 75 KVA to 100 KVA. |
| 21 | All as per item No 19 here-in-before but for DG set of capacity 250 KVA to 320 KVA . |
| 22 | Supply and Fixing in replacement battery charger heavy duty 180 AH, 9 to 24 volts adjustable battery lead, with ampere meter complete all as specified and directed. |
| 23 | Supply and top up of engine oil 15W30 complete all as specified and as directed. |
| 24 | Supply and top up of coolent for DG Set radiator complete all as specified and as directed. |
| 25 | Supply and fixing of automatic voltage regulator of existing model/make suitable for DG sets of capacity 25 KVA to 62.5 KVA complete all as specified and as directed. |
| 26 | All as per item No 25 here-in-before but for DG set of capacity 75 KVA to 100 KVA. |
| 27 | All as per item No 25 here-in-before but for DG set of capacity 250 KVA to 320 KVA . |
| 28 | Supply and fixing fan belts of existing model/make suitable for DG sets of capacity 25 KVA to 62.5 KVA complete all as specified and as directed. |
| 29 | All as per item No 28 here-in-before but for DG set of capacity 75 KVA to 100 KVA. |
| 30 | All as per item No 28 here-in-before but for DG set of capacity 250 KVA to 320 KVA . |
| 31 | Supply and fixing of self starter 12 volts suitable for DG sets of capacity 25 KVA to 62.5 KVA complete all as specified and as directed. |
| 32 | All as per item No 31 here-in-before but for DG set of capacity 75 KVA to 100 KVA. |
| 33 | Supply and fixing of self starter 24 volts suitable for DG sets of capacity 250KVA to 320KVA complete all as specified and as directed. |
| 34 | Supply and fixing on laod change over switch conforming to IEC 947-3 EN-60947-3AC-23A front operated 4 pole 415V, 50HZ with sheet steel enclosures of capacity 200 Amps complete all as specified and as directed. |
| 35 | All as per item No 34 here-in-before but of capacity 250 Amps. |
| 36 | All as per item No 34 here-in-before but of capacity 400 Amps. |
| 37 | Supplying and installing lead acid battery 12 V 110 AH sealed, maintenance free including all connections complete all as specified and as directed. |
| 38 | Supplying and installing in replacement of lead acid battery 12 V 180 AH sealed, maintenance free including all connections complete all as specified and as directed. |
| 39 | Supply and fixing in replacement of Battery Lead, PVC insulated multi stranded copper conductor with copper lugs & terminal of suitable size of length 1.5 Mtr complete all as specified and as directed. |
| 40 | Supply and fixing in replacement LED display & control unit displaying running time, oil pressure, temp sensors set points, remote and local start/stop capabilities suitable for DG sets of capacity 250 KVA to 320 KVA, complete all as specified and as directed. |
| 41 | All as per item No 40 here-in-before but for DG set of capacity 25 KVA to 100 KVA . |
| 42 | Material and labour for servicing, repairing, maintenance of alternator assembly by opening/removing from DG set of capacity 25 to 100 KVA, replacement of carbon bush holder with carbon bush, bearing, mopeds, defective rectifier, capacitor, armature winding and refixing the same in original position complete all as specified and directed. |
| 43 | All as per item No 42 above here-in-before but 250 KVA to 320 KVA. |
| 44 | Supply and fixing in replacement of Shut down valve of DG set of any make /capacity complete all as specified and directed. |
| 45 | Supply and fixing in replacement coupling of alternator & engine with necessary nut bolts, key set complete all as specified and directed. |
| 46 | Material and labour for maintenance/ repair/ servicing of automatic mains failure panel 24 V DC and 440 V AC supply operated system, locating faults of the following and replacement of unserviceable parts/components(a) Repair of faulty worn out control wiring DC/AC for engine starting and off with adequate & suitable size of copper wire connected with proper copper lugs & terminals through protection pipe / casing complete.(b) Repair of worn out/ faulty internal wiring of controls and timers, indicating measuring instruments through various control fuses and relays with suitable and adequate size of copper wire, connected with suitable copper lugs and terminals complete.(c) Replacement of worn out small control fuses, indicating lamps, various type of copper lugs, thimbles terminals all as deemed necessary spares and components in order to make system serviceable/ functional(d) Material and labour for painting of AMF panel metallic body surface with superior synthetic enamel paint of approved colour and quality one under coat and one fnishing coat including replacement of worn out rubber beeding complete all as specified and directed. |
| 47 | Supply and fixing in replacement Solid state electronic engine starting relay 12/24 volt DC with relay card of existing make and size complete all as specified and directed. |
| 48 | Supply and fixing in replacement Alternator voltage monitor relay 3 phase 415 V of existing make and size complete. |
| 49 | Supply and fixing in replacement Solid state electronic timer 0-60 sec, 12/ 24 volt DC of existing make and size complete all as specified and directed. |
| 50 | Supply and fixing in replacement selector switch auto/ manual/ test 24 volts DC of existing make and size complete all as specified and directed. |
| 51 | Supply and fixing in replacement of MCCB 630A 4pole 36KA with adjustable overload and adjustable short circuit of existing make and size complete all as specified and directed. |
| 52 | Supply and fixing in replacement MCCB 400A 4pole 36KA with adjustable overload and adjustable short circuit of existing make & size complete all as specified and directed. |
| 53 | Material and labour for painiting of complete base and canopy of DG Set from inner/outer side of capacity 25 to 320 KVA by applying two coats of anti-corrosive paint in different existing colours over a coat of red oxide zinc chrome primer after preperation of all exposed steel surfaces including necessary scraping of rust occured on iron and old corrode paint complete all as specified and directed. S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 Please Enable Macros to View BoQ information |