| 1 | wiring |
| 2 | 90.15.4.8:Supply Conveyance, installation, testing and commissioning of 120W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 3 | OD500316/2025-2026: Supply Conveyance, installation, testing and commissioning of Digital Time Switch Relay 230V AC Contact1 C/O SPDT, Relay Rating 16A / 20 Mounting on DIN Rail Mount including connections etc as required |
| 4 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 5 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 6 | OD500320/2025-2026:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GSMB- 6535) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making good the damages colour washing etc. as required. |
| 7 | OD500290/2025-2026:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc |
| 8 | OD500292/2025-2026:Supplying and fixing 32 A, HRC Fuse with HRC Fuse link with connections, in existing meterboard |
| 9 | OD500288/2025-2026:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base withconnections, in existing meter board |
| 10 | 1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm |
| 11 | OD500294/2025-2026:Dismantling the existing damaged flood lights, and all other related items from pole conveyed and handed over to to the agreement authority with reciepts Please Enable Macros to View BoQ information |