| 1 | Development work of Ramlila Maidan at Aishbagh in District –Lucknow (U.P.) |
| 2 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Brick Work with common burnt clay ( non modular) bricks of class - 150 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 7 | Foundations, footings, bases of columns, etc. for mass concrete |
| 8 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 9 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 11 | 12 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand. On smooth surface of wall. |
| 12 | 15 mm thick plaster with cement mortar in consisting of 1:6 cement. On rough surface of wall. |
| 13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 15 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 16 | R.C.C. RETAINING WALL |
| 17 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m.(5 fts.) and lead upto 30m.(100 fts.) & including filling. watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-incharges upto a distance of 30 m.(100 fts.) from the foundation trenches. |
| 18 | Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation |
| 19 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in Raft foundation excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Strength of the concrete shall not beless than M- 200. |
| 20 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in Column excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Strength of the concrete shall not beless than M- 200. |
| 21 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 22 | Shuttering Work |
| 23 | BACK SIDE BOUNDARY WALL |
| 24 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 26 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 27 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 28 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 29 | 12 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand. On smooth surface of wall. |
| 30 | 15 mm thick plaster with cement mortar in consisting of 1:6 cement. On rough surface of wall. |
| 31 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 33 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 34 | DISMENTLING WORK |
| 35 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material unserviceable material and disposal of unserviceable material within 50 metres lead as per direction of In cement mortar |
| 36 | Disposal of malba . 5.0 KM |
| 37 | Electric work |
| 38 | SWITCH CONTROL LIGHT POINTS |
| 39 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 40 | Light Point (Front Side Column) |
| 41 | Light Point ( Back Side Column) |
| 42 | Light Point ( Front Side wall Face) |
| 43 | MCB CONTROL LIGHT POINTS |
| 44 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 45 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 46 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 47 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 48 | 6 module (78mm X 205 mm X 50 mm) |
| 49 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 50 | 25 mm |
| 51 | Supply, Installation, Testing and Commissioning of 9W Victorian Design Stylish Outdoor Harbor Gate Piller Light (All Type Colour) complete in all respects. |
| 52 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 53 | 6 way, Double door |
| 54 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 55 | Single Pole |
| 56 | Single Pole Neutral |
| 57 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 58 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 59 | EARTHING |
| 60 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 61 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 62 | GST Extra as applicable Please Enable Macros to View BoQ information |