| 1 | Steam Indicator Tap Class I | Lead Free Autoclave Tape roll |
| 2 | Steam Indicator Tap Class 5 Moving front technology | Self Adhesive Moving front Chemical integrators indicating Accept orReject to verify all perimeters of steam sterilization together i e Time Temperature and Quality of steamCan be used for pack control monitoring of all 118 138C 245 280F steam sterilization cyclesShould be compliant to BS EN ISO 11140 1 2005Should have 510 k registrationShould have a BSI Kitemark Certificate Pack of 500 PC 2 box case |
| 3 | Steam Biological Indicators SRBI | Rapid readout biological indicators for steam sterilization containing astandardized viable population of Bacillus stearothermophilus sporesThe indicator detects the presence of viable spores by the production of fluorescence in 3 hours in conjunction with Rapid Readout IncubatorDesigned and certified as per ISO 11138 and EN 866Should be compatible with the following cyclesa) 121 123C gravity steam sterilization Cycleb) 132 135C vacuum assisted steam sterilization cycles Should be compliant to ISO 11138 1 2006 en Part 1 and ISO 111381 2006 en Part 3Every box should contain Quality Assurance certificate with mention of Spore population D value Z valueShould have a BSI Kitemark CertificateShould have FDA clearance |
| 4 | ETO Cartridge 100 gram Big ETO | for ETO sterilization |
| 5 | ETO Cartridge 40 gram Small ETO | for ETO sterilization |
| 6 | ETO Bio logical Indicators SRBI | Rapid readout biological indicators containing a standardized viable populationof Bacillus Atropheus spores for ETO Sterilization CyclesThe indicator detects the presence of viable spores by the production of fluorescence within 4 hours in conjunction with Rapid Readout IncubatorDesigned and certified as per ISO 11138 and EN 866 Should be compliant to ISO 11138 1 2006 en Part 1 and ISO 111381 2006en Part 2Every box should contain Quality Assurance certificate with mention of Spore populationD value Z valueShould have a BSI Kitemark CertificateShould have FDA clearance |
| 7 | Bowie Dick Pack Lead Free | ISO 11140 1 2014 and 11140 5 2007Designed for testing air-removal efficiency of 132 134 C 270 273 F dynamic air removal steam sterilizersTest pack will reproducibly detect residual air in the sterilizer chamber due to air leaks, air removal failures and inadequate vacuum by testing the air removal efficiency of 132 134 C 270 273F dynamic air removal steam sterilizersIndicator sheet will turn a uniform dark color except when air removal failures such as air leaks occurLead freeEquivalent in performance to the Bowie Dick Towel Pack described in ANSI AAMI ST79Does not change visually 24 months when properly stored Includes a scanable 2D bar code with lot number and expiration date for record keepingIncludes a process indicator on the test pack label Preassembled, single use designed for consistent performance results additional sponge sheet inside the pack for more challengeInk pattern design for easy interpretation Two year shelf lifeSheet can be filed for record keeping |
| 8 | Ultra Rapid Multienzyme cleaner 1 Liter | Multiple enzymatic concentrate solution with lipases cellulases proteases and amylasesMust act against all possible body secretions compatible to all instrumentsFast acting within 2 10 minutes allow safe disposable via the drain after useLeaves no residue after wash Stable formulation with near neutral pHShould have scale inhibition propertiesShould help retain shine of the instrumentShould be usable for manual ultra sonic and automatic cleaning systemsProperties should have been tested by methods prescribed by NACE TM0374 2007 NACE TM0169 ASTM G31 2012 1 Liter |
| 9 | Fabric incise drape iodinised | Incisde drape made up of Polyester film with an acrylic adhesive that contains a complex of iodoform N vinyl 2 pyrrolidine with a iodine concentration of 0 092 mg Iodine cm2 Film should be breathable and conformable to skin compatible with Povidone and CHG skin preps Iodine from the drape should be present in the deepest skin layers 1000 microns depth where hair folices exist apart from killing microbes on skin layer Size 56 45 cm with frame delivery mechanism which allow application by single person |
| 10 | Fabric incise drape iodinised | Incisde drape made up of Polyester film with an acrylic adhesive that contains a complex of iodoformN vinyl 2 pyrrolidine with a iodine concentration of 0 092 mg Iodine cm2 Film should be breathable and conformable to skincompatible with Povidone and CHG skin preps Iodine from the drape should be present in the deepest skin layers 1000 microns depth where hair folices exist apart from killing microbes on skin layer Size 34 35 cm with frame delivery mechanism which allow application by single person |
| 11 | CHG 4 PER Scrub 500ml | Pre Operative surgical hand scrubbing washing by 4 PER Chlorhexidine solution can be used for patient s skin 500ml scrubbing cleansing and also for body washing showering should have moisturizer emollients to prevent skin damgeage dryness and irritation should provide higher foaming and grater viscocity to avoid wastage should have long persistent action Broad Spectrum persistentand cumulative antimicrobial activity slotution Chlorhexidine Gluconate IP |
| 12 | Skin Prep CHG 2PER Solution and 70PER Isopropenol Alcohol in 500Ml | Chlorhexidine Gluconate Scrub Solution 2 PER w v equivalent to 10PER v v Broad spectrum Bactericidal Fungicidal Virucidal and Sporicidal antimicrobial solution for skin preparation in a translucent bottle with volume calibration 500ml bottle |
| 13 | ETO Packing Roll Size 100 200 | for ETO sterilization |
| 14 | ETO Packing Roll Size 150 200 | for ETO sterilization |
| 15 | ETO Packing Roll Size 250 200 | for ETO sterilization |
| 16 | ETO Packing Roll Size 400 200 | for ETO sterilization |