| 1 | Supply of 70W Street Light Lumen Efficacy >120 , CRI>70, CCT -5700K, IP - 66, Aluminum Dia Cast Housing , Potted driver. Inbuild Surge Protection 4kv Internal & 10 kv external LM 79 Report shall be provided from manufactures own NABL Lab and LM 80 from Nichia/Osram/Lumiled/Seoul/Bridge Lux – 5 Years Warranty Make - Philips/ Bajaj / Wipro / Mazik/Surya Cat no. SLE UL 72W IP66 PLX XL) (Cromton light rating should be higher than fitting rateing) |
| 2 | Supply of IP65 post top lantern. Make- Philips cat no. BGP200 LED45 CW PSU GR CPC SPD / Bajaj / Wipro ) ( 5 Yrs worrenty) |
| 3 | Fixing only bulk head ceiling fitting on wall /ceiling by screws etc. |
| 4 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required andmending good damages to wall incl. painting etc. |
| 5 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required -- for interconnection 3 x 22/0.3 (1.5 sqmm) |
| 6 | S/F PVC loop box of size 103 mm x 103 mm x 73 mm (Make - Hensel/Sintex) suitable for housing the water-tight switch and providing the wire lead in lead out arrangement for 6A SP MCB (Legrand/Semens/Cabtree as par direction of EIC) and lamp holder connection. One side of the cover lid of the box is to be hinged type and the other side with proper clamping and locking arrangement the box. The set is to be fixed in suitable position on iron leg on wall as per direction of Engineer-In-Charge. |
| 7 | Supply & Delivery 1.1 kv gr. 2 core 10 sq.mm. XLPE Al. armoured cable as per direction of EIC (Make Gloster/Polycab/RR Kabel |
| 8 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 9 | Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish ---- From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc |
| 10 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 40mm dia |
| 11 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :2 core 10 sqmm cable |
| 12 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 2 core 10 sqmm cable 2 core 10 sqmm cable |
| 13 | Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil |
| 14 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe |
| 15 | Add G.S.T 18% on aggregate amount of BOQ item No 1 to 18 |
| 16 | Add LW Cess 1% on aggregate amount of BOQ item No 1 to 18 (after add G.S.T 18 %) Please Enable Macros to View BoQ information |