| 1 | Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and forecast concrete articles, complete all as specified and directed. |
| 2 | Demolition of cement concrete unreinfoced in ground floor and paving n exc 15 cm thickness ( below or above ground level) and removing the unserviceable materials to a distance n exc 100m complete all as specified and directed. |
| 3 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed. |
| 4 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and directed. |
| 5 | M&L RCC M-25 nominal mix foundations, type B-1-1:2:4 ( Using 20 mm graded stone aggregate) for Foundations, including Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footing rafts complete all as specified and directed. |
| 6 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, faces of walls, retaining walls, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 7 | M&L for Brickwork with fly ash Modular bricks, straight or curved on plan exc 6m mean radius, built in cement mortar CM 1:6, complete all as specified and directed. |
| 8 | M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed. |
| 9 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 10 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 11 | M&L for Cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in surface channels and drains complete all as specified and directed. |
| 12 | Extra for forming fair finished channel 30 to 60 cm inner girth in cement concrete using extra cement including moulds mitred stopped ends etc. complete all as specified and as directed. |
| 13 | M&L for 10 mm thick rendering in cement mortar (1:4) on fair faces of brick work, mixed with WPC 3% wt of cement inclduing finishing surfaces even and fair without using extra cement complete all as specified and directed. Note : WPC will be measured and paid separately. |
| 14 | Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed. |
| 15 | Supply only liquid integral water proofing compund. Make Dr Fixit/ Pidipfoor/ LW+. |
| 16 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping, benching, bed block, cills like including weathering and slightly rounded etc including form work, complete all as specified and directed. |
| 17 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 18 | M&L for Pre-cast cement concrete type B-1 (1:2:4) (using 20mm graded stone aggregate) as in drain cover slabs set in cement mortar 1:6 including necessary formwork complete all as specified and directed. |
| 19 | S&F Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including ranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Fe-410-W (Gde.E-250)Part- I quality-A orFe 290 (Gde -E-165) complete all as specified and directed. |
| 20 | M&L for plain Cement concrete 1:5:10 type E-2 (using 40mm graded stone aggregate) as in mass-concrete/foundation or floor complete all as specified and directed |
| 21 | M&L 60mm thick rubber moulded glosy finished inter locking paver block with grey cement and pigment of any type and shape the minium compressive strenth not less then 350 kg/sqcm as approved complete all as specified and directed. |
| 22 | M& L for Sand filling under floor including watering and consolidation, complete all as specified and directed. |
| 23 | M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius except bricks built in CM 1:6, complete all as specified and directed. |
| 24 | S&F 75 mm dia PVC (SWR) rain water pipe confirming to latest IS 13592 (Type A) single socketed, in any length fixed in RCC/ Brick wall for weep holes complete all as specified and directed |
| 25 | S&F for FRP (Fibre Reinforced Polymer) L Angle of size 45X45X4 ( mm) for Supporting Cover / Gully Cover for manhole/ gulley trap/ over strom water drain and other required places including necessary fixing work over frame complete all as specified and directed |
| 26 | S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 27 | Providing and Fixing for ractangular Light Duty ( load carrying capacity minimum 5 MT) composite FRP (Fibre Reinforced Polymer) Gully Cover of size 660mmX960mm over strom water drain and other required places including necessary fixing work over frame complete all as specified and directed |
| 28 | Providing and Fixing for ractangular Light Duty ( load carrying capacity minimum 5 MT) composite FRP (Fibre Reinforced Polymer) cover of size 660mmX960mm for inspection chamber /manhole/ gulley trap/ over strom water drain and other required places including necessary fixing work over frame complete all as specified and directed |
| 29 | Schedule of Credit (MINUS) Rs. 53,295.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum Please Enable Macros to View BoQ information |