| 1 | Material and labour for Earthing complete with copper earth plate 60×60cm.× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper strip of 20X3 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. |
| 2 | Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25X3 mm Aluminium strip. |
| 3 | Supply and laying of PVC insulated, armoured, heavy duty electric cable 4 core , 1100 volts grade, aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed , cross-sectional area 25 sq. mm (Make:Havells/Gloster/Orbit/ Polycab) or suitable equivalent make |
| 4 | Excavating in trenches hard dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cable. |
| 5 | Demolition of cement concrete of any description and in any position unreinforced. |
| 6 | Material and labour for cement concrete 1:2:4 Type B1 using 20mm graded aggregate in foundations, filling and mass concrete. |
| 7 | Material & labour for sand filling for cushioning on U.G cable |
| 8 | Materal &labour for Bricks; common burnt clay building bricks sub class B designation 75, Old size bricks for protection to U.G cable |
| 9 | Returing, refilling of hard/dense soil in the excavated trench after laying of power cable including spreading levelling, watering and well ramming in layers not exc 25 cm. |
| 10 | Supply and fixing of Galvanised steel tubes of 50 mm, medium grade. |
| 11 | Supplying, Installation, Testing & Commissioning of LED Flood Light of 200 Watt, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥ 0.95, IP-66,IK-10, CRI ≥ 70, System lumen efficacy ≥ 135 lm/Watt),under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 4000°K / 5700°K (As per ANSI Bin) ,SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Make:Bajaj/Havells/Philips/Wipro/CG or its suitable equivalent make. |
| 12 | Supply, installation, testing and commissioning of 16 Meter high mast lighting pole. (As per specifications in Annexure-I, Sl.No. 1 to 8.7) |
| 13 | Supply, installation, testing and commissioning of feeder piller control panel. (As per specifications in Annexure-I Sl No.9.1 to 9.12) Please Enable Macros to View BoQ information |