| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required (DSR 1.8) |
| 2 | Group C (DSR 1.8.3) |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required (DSR 1.15) |
| 4 | Group C (DSR 1.15.3) |
| 5 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required (DSR 1.17) |
| 6 | 3 x 2.5 sq. mm (DSR 1.17.12) |
| 7 | 3 x 4 sq. mm (DSR 1.17.21) |
| 8 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required (DSR 1.21) |
| 9 | 25 mm (DSR 1.21.2) |
| 10 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required (DSR 1.23) |
| 11 | 5/6 amps switch (DSR 1.23.1) |
| 12 | 15/16 A switch (DSR 1.23.3) |
| 13 | 3 pin 5/6 A socket outlet (DSR 1.23.4) |
| 14 | 6 pin 15/16 A socket outlet (DSR 1.23.5) |
| 15 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required (DSR 1.29) |
| 16 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required (DSR 1.30) |
| 17 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. (DSR 1.33) |
| 18 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (DSR 2.3) |
| 19 | 6 way , Double door (DSR 2.3.1) |
| 20 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (DSR 2.4) |
| 21 | 4 way (4 + 12), Double door (DSR 2.4.1) |
| 22 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required (DSR 2.5) |
| 23 | 4 way (4 + 12), Double door (DSR 2.5.1) |
| 24 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (DSR 2.10) |
| 25 | Single pole (DSR 2.10.1) |
| 26 | Double pole (DSR 2.10.3) |
| 27 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. (DSR 2.16) |
| 28 | Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required (DSR 4.1) |
| 29 | 150 mm width X 50 mm depth X 1.6 mm thickness (DSR 4.1.2) |
| 30 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia includingaccessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR 5.2) |
| 31 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required (DSR 5.4) |
| 32 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (DSR 5.15) |
| 33 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. (DSR 5.16) |
| 34 | LED Down lighter (SMD Type) (System lumen Unit Rate efficacy ≥ 105 < 120 lm/Watt ) (DSR 8.1) |
| 35 | Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type |
| 36 | 12 -15 watt (DSR 8.1.3) |
| 37 | LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) (DSR 8.7) |
| 38 | Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver |
| 39 | 36 watt (DSR 8.7.4) |
| 40 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). (DSR 8.9) |
| 41 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) |
| 42 | 18-22 Watt (DSR 8.9.1) |
| 43 | Supply, installation, testing & commissioning of 63 Amp MCB TPN, 10kA, 'C' curve in the existing distribution board, complete in all respect to the entire satisfaction of E.I.C. (Ref N.S.) |
| 44 | Supply, installation, testing & commissioning of 63 Amp MCB TP, 10kA, 'C' curve in the existing distribution board, complete in all respect to the entire satisfaction of E.I.C. (Ref N.S.) |
| 45 | Supplying and fixing 100W socket type 5 step fan regulator on existing plate with all petty materials complete in all respect to the entire satisfaction of the E.I.C. (Ref N.S.) |
| 46 | Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 1 star rated (min), ceiling fan, double ball bearing, 100% copper wound motor with 3 nos. blades, down rod as per site requirement, 2 nos. canopies, shackle kit, safety rope, Power Factor not less than 0.9, Air delivery minimum 210 Cum/Min, THD less than 10%, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (Ref N.S.) |
| 47 | Supplying, installation, Testing & Commissioning of Panel light 36 Watt, 1x4 ft., Operating voltage AC 140-270 Volt, frequency 50/60 hz, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P.F.≥0.95, CCT 5700°K, System lumen efficacy ≥105 <120 lm/Watt output. The job includes connection of light with nearest electrical point with 1.5sqmm FRLS PVC insulated copper conductor cable complete in all respect to the entire satisfaction of the E.I.C. (Ref N.S.) |
| 48 | Supplying, installation, testing & commissioning of MCCB 125A 4P 36KA TMD Release with adjustable overload & adjustable short circuit protection, Ics =100% of Icu in the existing vertical TPN BDB complete in all respect to the entire satisfaction of E.I.C. (Ref N.S.) |
| 49 | Supply and laying of XLPE insulated PVC inner sheathed aluminum conductor Un-Armoured (3.5 core) cable of size 25 sqmm on the existing cable tray complete in all respect to the entire satisfaction of the E.I.C. (Ref N.S.) |
| 50 | Supplying, Installation, Testing and Commissioning of Metallic Wall Fan 450mm sweep equipped with three blades speeds at up to 1350RPM to deliver sufficient airflow and ventilation across the room. The fan should have thermal overload protection, low noise operation and smooth oscillation enabling the fan to turn back and forth in a jerk-free movement. (Ref N.S.) |
| 51 | Supply and Erection of \\"D\\" Type Fan Hook at site with 2 Nos fasteners complete in all respect to the entire satisfaction of the E.I.C. (Ref N.S.) |
| 52 | Supply and Erection of Exhaust Fan (Copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver. The job includes carriage charges, connection, testing, commissioning etc as required to complete the job to the entire satisfaction of the E.I.C. (Ref N.S.) |
| 53 | 300MM Sweep with louver. Please Enable Macros to View BoQ information |