| 1 | Safe carriage loading unloading with proper stacking of following material from ESC Daliganj to Work Site/JE dump store. |
| 2 | 11 KV 3 Way RMU |
| 3 | 11 KV 3x185 Sqmm O/D S/T, I/D Kit |
| 4 | 11 KV 3x120/185 Sqmm XLPE Cable |
| 5 | PCC Pole 8.5/11 Mtr. |
| 6 | STP Pole 11 Mtr. |
| 7 | 11.04 KV 250 KVA T/F |
| 8 | 11 KV Disc Insulator With Fitting |
| 9 | 11 KV Pin Insulator |
| 10 | 11 KV Fuse Set |
| 11 | LT ABC Cable (3x120+1x95+1x16 sqmm) |
| 12 | LT PVC Cable (1x400 Sqmm) |
| 13 | Stay Set Complete |
| 14 | M.S Earthing Rod |
| 15 | Barbed Wire G.I |
| 16 | ACSR Weasel Conductor |
| 17 | X/V Type Arm MS Angle |
| 18 | ACSR Dog Conductor |
| 19 | All Decentralized Items Provided/Fixing/ Erection/Installation/Laying/Foundation with earthing by the contractor as on his own cost as per RESPO Narms.33 KV LINE ERECTION WORKMinimum depth of laying from ground surface to the top of cable as per IS is1)Low Voltage (1.1KV) and control cable 0.75 Mtr2) 3.3 KV to 11 KV Cables 0.90 Mtr3) 22 KV to 33 KV Cable 1.05 Mtr4) Cables at Road Crossing 1.00 Mtr5) Cable at Railway Laval Crossing ( measured from bottom 1.00 Mtr Of sleepers to top of pipe) Note- 1- The depth may be increased but not more than 1.6 Mtr 2- The Standard depth and width for laying the cable are also attached ( as per letter No 561/Director(Tech)/MVVNL/Camp/Dt 09.01.2026 with the tender form) |
| 20 | Installation and commissioning of RMU by fasting with foundation bolts connected of all three side cable termination setting of relay according to load at particular place and connected with bore earthing by GI strip. |
| 21 | Construction of RMU plinth of size 1.5x1x1 mtr with the help first class brick, sand & cement including plastering and other work required for complication of work in all aspect. All Material shall be supplied by contractor. |
| 22 | Wiremess fencing of 11 KV Ring Main Unit shall be made of rectangular of size as per site requirement not exceeding 2 meter fabrication 45x45x5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mesh. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with Ms flat of size 25x3mm to support as per RESPO specification & direction of E/I. |
| 23 | Chemical Earthing system with outer pipe diameter 50mm, inner Strip 40x6, length 3000 mm. galvanization up to 200 micro, earthing pipe with crystalline conductive mixture filled inside the pipe with anti-corrosion & high conductive along with 50 Kg(As per required) of BFC which should be capable to reducing the soil resistively with good moisture retaining capacity.(Specification of chemical earthing and drawing is hereby enclosed). All material shall by supply by the contractor. |
| 24 | Laying of 3X120/185 sq.mm 11 KV XLPE cable by Manual method as per RESPO Norms. Only 11 KV XLPE cable supplied by Department. |
| 25 | Laying of 3X120/185 sq.mm 11 KV XLPE cable by Drill method as per RESPO Norms. Only 11 KV XLPE cable supplied by Department. |
| 26 | Construction of T/F plinth of size 2x2x1.2 mtr with the help first class brick & masonry in the ratio 1:4 cement & sand coarse. Filling the structure completely per norms with RCC to 1:2:2 cement & stone grit with MS bar and MS channel for resting transformer. |
| 27 | Wiremess fencing of 11/0.4 KV S/S shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mesh. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with Ms flat of size 25x3mm to support as per RESPO specification & direction of E/I. |
| 28 | Well type/Bore type earthing of with 60 Fit Deep boring and providing GI Pipe 1.5\\" dia (\\"B\\" Class) and earthing must be joint by G.I. Strip of 32x5 mm thick long attached with nut & bolts and GI pipe cap. All material and labour shall be supplied the contractor. |
| 29 | Fabrication, errection & commissioning of 250 KVA T/F on Plinth with all accessories. All material except 250 KVA T/F shall be supplied by the Contractor. |
| 30 | Proper laying & commissioning of (3X95/3X120 sq.mm) Aerial Bunched Conductor. Only ABC Provided by deptt. |
| 31 | Laying of LT XLPE/PVC Cable 3.5x150/3.5x400/1x240//1x400/1x630 sq.mm. as per RESPO Norms. Only cable shall be supplied by department. |
| 32 | Construction of masonry/metallic type distribution pillar of size 1x1.5x2.5 mtr. with supply & fixing of fabricated 4 nos. doors (2ft.x4ft.) made of BP sheet of 18 SWG with locking arrangement, 2 Nos. Straight MS angle 50x50x6mm (1800 mm long) 2 nos. 500 Amp, 3 Nos. 300 Amp Henley Type tailless fuse Unit, 3 Nos copper bus bar of size 1000x50x6 mm and one No. Alum busbar 1000x50x6 mm including all civil material required for work. All material shall be supplied by contractor. |
| 33 | Grouting & Nuzzling of 11 KV stay set complete including fixing of necessary clamps. Accessories required including its grouting by civil material (Sand, Brick blast & cement). All material except stay wire shall be supplied by the contractor. |
| 34 | Ordinary earthing by 11 KV MS earth Rod 2500mm long as per RESPO Schedule. All material except earthing wire shall be supplied by the contractor. |
| 35 | Dragging of ST/PCC Pole digging of pit erection of sub-station type double pole structure on ST/PCC Pole with fixing of necessary item such as Top Channel, along with grouting (As per RESPO Norms) Dropper Channel, 11 pin insulator with Pin & 11 KV Disc Insulator with fitting, DO Fuse set its ramming, as per RESPO Specification. Only Pole and insulator will be Provided by the Department. |
| 36 | Supply and fixing of 11 KV TPMO as per RESPO Norms. |
| 37 | Laying Stringing & sagging of 3 Phase 3 wire 11 KV New Line on ACSR Wesal/Racoon/Dog conductor as per RESPO Specification and direction on E/I. All material exept ACSR wesal /Racoon/Dog conductor shall be supplied by the contractor. |
| 38 | Supply & Fixing of Cable Route Maker |
| 39 | Cable Hosting of 11 KV 3x70/3x120/3x185 sq. mm XLPE Cable at the following including jumpering etc complete with help of GI Pipe as Per RESPO Norms. GI pipe and other required material shall be supplied by contractor. |
| 40 | Dragging of ST/PCC Pole to pit site, digging of pit erection and grouting (As per RESPO Norms) of 11 KV line with fixing of necessary item, such as V-type X-arm, F-bracket, 11 KV Pin insulator, Gaurding angle (1.8 mm 65x65x6) with Nut & bolts its ramming as per RESSPO Specification. Only Pole and insulator will be Provided by the Department. |
| 41 | Cable laying of 11 KV 3x70/3x120/3x185 sq. mm XLPE Cable with help of HDPE Pipe as Per RESPO Norms. HDPE pipe and other required material shall be supplied by contractor. (HDPE Pipe 140m.m) Please Enable Macros to View BoQ information |