| 1 | Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area. |
| 2 | 33 KV XLPE cable 3x300 mm2 |
| 3 | ST Pole 11 Mtr. |
| 4 | Cable jointing kit ST. TH. 33KV 3*300 sqmm |
| 5 | Cable jointing kit outdoor 33KV 3*300 sqmm |
| 6 | 33 kV Polymeric Pin Insulator with GI Pin |
| 7 | 33 kV Pin with Nut |
| 8 | top channel 125*65*6 mm |
| 9 | MS angle 65*65*6 mm |
| 10 | Stay set Complete |
| 11 | LT XLPE 1*400 sqmm cable |
| 12 | MS Earthing Rod |
| 13 | All Decentralized Items Provided/Fixing/ Erection/Installation/Laying/Foundation with earthing by the contractor as on his own cost as per RESPO Narms.33 KV LINE ERECTION WORKMinimum depth of laying from ground surface to the top of cable as per IS is1)Low Voltage (1.1KV) and control cable 0.75 Mtr2) 3.3 KV to 11 KV Cables 0.90 Mtr3) 22 KV to 33 KV Cable 1.05 Mtr4) Cables at Road Crossing 1.00 Mtr5) Cable at Railway Laval Crossing ( measured from bottom 1.00 Mtr Of sleepers to top of pipe) Note- 1- The depth may be increased but not more than 1.6 Mtr 2- The Standerd depth and width for laying the cable are also attached ( as per letter No 561/Director(Tech)/MVVNL/Camp/Dt 09.01.2026 with the tender form) |
| 14 | Fabrication & erection of 33 KV cable exposure type double pole with the provision of separate bus bar for each cable with fixing of necessary clamps and other accessories like danger board, number plate, barbed wire, 6 no. pin insulators with pins,2 no. channels 125x65 mm (1600mm each),1 no.MS channel 125x65mm(3200mm in length) and 2 no.MS angle 65x65x6 mm (each 3200mm in length) for supporting the hoisting of cable &poles. Its jumpering by single core PVC aluminum cable with proper size of lug. (all material arranged by contractor except steel, pole, PVC aluminium cable & insulator).as per RESPO norms. |
| 15 | Making proper marking of cable by marking tape/marking tag at proper interval (everymtr underneath) marking tape /tag provided by contractor |
| 16 | Laying of 33 kV 3x300 sq. mm XLPE cable D/C including digging of trench 1050 mm deep, 750 mm wide along with required material Sand (0.195 CubMtr), Ist class bricks(26.25 Nos/Mtr), stone pad (2.2 Nos size 600x750x50 mm).The inter axial spacing between two cable should be in between 0.32 M to 0.40 M. (As per JE instruction) and back filling the trench by sol (All the material required for laying will be supplied by the contractor except 33 kV XLPE cable) |
| 17 | Cable laying By HDD drill method S/C |
| 18 | Digging of Pit in kachcha/Pakka land in 1.2 mtr deep 3 mtr long and 2 mtr wide for 33 KV ST/TH 3x300 sq mm and boxing with brick sand and stone slab as per norms. |
| 19 | Hoisting of 33KV XLPE cable on double pole with Gl pipe of size 5/6\\" dia 3 M long including its jumpering complete with clamps, nuts and bolts(all material arranged by contractor). |
| 20 | Route Survey & profiling of 33 KV line from 132 KV s/s PGI to new proposed D/P( Length 1 km) |
| 21 | Plotting of cable layout rute on graph paper (i.e. depth underneath and distance from either side from prominent reference fixed point ) the reference point must not be more than 100 mtr. |
| 22 | Ordinary Earthing of pole by M.S. Earthing Rod 20x2500 mm as per Resspo Norms only earting rod provided by dept |
| 23 | Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick ballast as per RESPO norms. |
| 24 | Painting of new erected ST pole with two coat of red oxide paint,PO red paint at top of pole 2 M & balance b two coats of best quality aluminum Raint by of Burger/Nerolac/Asian mark as per norms |
| 25 | High Pressure Testing and fault location of 33 cables/line/ as per norms |
| 26 | SCANING/ TRACING OF EXISTING UNDERNEATH POWER 82.00 CABLES, WATER PIPE LINE, GAS PIPE LINE, SEWER PIPE LINE ON PROPOSED ROUTE TO AV OID POSSIBLITES OF ANY KIND OF DAMAGE DURING DIGGING OF TRENCH/DRILOING FOR LAYING CABLE. (SCANNING MA |
| 27 | Return back balance material & Cable Drum from site to LESA store daliganj. |
| 28 | Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area. |
| 29 | 33 KV VCB 1250 A |
| 30 | 33KV CT 400/200/1-1 A |
| 31 | Lightening Arrester |
| 32 | 33 KV C&R Panel for single feeder |
| 33 | Top channel 125*65*6 mm |
| 34 | MS angle 65*65*6 mm |
| 35 | Installation and Commissioning |
| 36 | Fabrication of 33 KV Lightening arrester/CT structure with foundation as per RESPO norms. |
| 37 | Construction of control cable trench as per RESPO norms |
| 38 | Construction of control cable trench cover as per RESPO norms |
| 39 | Construction of VCB plinth as per RESPO norms |
| 40 | Installation, connection and testing of 33 KV C&R panel for single feeder as per RESPO norms |
| 41 | Installation, connection and testing of 33 KV LA/CT as per RESPO norms |
| 42 | laying and connection of control cable from VCB to Control Panel as per RESPO norms |
| 43 | Painting of new erected Structure with two coat of red oxide paint, after that two coat of best quality aluminum paint as per RESPO norms |
| 44 | Return back balance material from site to LESA store daliganj. |
| 45 | Safe Loading, Carriage & unloading of following Materials from Centre Store to Pit Site/J.E. Dump Store & JE Dump store to work site |
| 46 | 11M, ST Pole - SP - 55 Galvanized |
| 47 | 33 KV \\"V\\" type Cross arm |
| 48 | 33 KV Porcelains Pin Insulator |
| 49 | 33 kv Pin with Nut |
| 50 | ACSR Panther Conductor |
| 51 | Top Channel 125X65 mm 3200 mm long with clamp |
| 52 | MS Earth Rod (2540X20 MM ) |
| 53 | 33 KV Disc Insulator B&S Polymeric Type |
| 54 | 33 KV Disc Fitting for drop B&S type |
| 55 | Stay Wire ( 4 mm )7/8 SWG (GSS WIRE ) |
| 56 | Complete Stay 9GI Stay Rod 20x1800 mm, stay wire |
| 57 | Dragging of ST Pole digging of pit erection of Single pole structure on ST Pole with fixing of necessary item such as V type cross arm , along with grouting (As per RESPO Norms) . Pole , insulator , V type cross arms , will be Provided by the Department. |
| 58 | Supply and fixing of danger plate ( with name of line & line voltage ) with Pole clamp |
| 59 | Grouting with muffing of ST Pole ( As per RESPO Norms ) |
| 60 | Rod type earthing (All material except earthing rod and labour shall be supplied the contractor) AS PER RESPO NORMS |
| 61 | Dragging of ST Pole digging of pit erection of section type double pole structure on ST Pole with fixing of necessary item such as Top Channel, Dropper Channel, 33 kv pin insulator with Pin & 33 KV Disc Insulator with fitting, , as per RESPO Specification.( only Pole , 33 kv pin insulater . 33 kv disc insulator will be Provided by the Department.) As PER RESPO NORMS |
| 62 | Dragging of ST Pole digging of pit erection of section type Four pole structure on ST Pole with fixing of necessary item such as Top Channel, along with grouting (As per RESPO Norms) Dropper Channel, 33 kv pin insulator with Pin & 33 KV Disc Insulator with fitting, , as per RESPO Specification.( only Pole , 33 kv pin insulator . 33 kv disc insulator , will be Provided by the Department.) AS PER RESPO NORMS |
| 63 | Supply & Fixing of different size nut & bolt with washer ( As par RESPO Norms ) |
| 64 | Tree Chopping at 33 kv Ashiyana Line for installing additional pole |
| 65 | Dismantling of existing double & four pole &cortège to dismantling site to je dump store & je dump store to daliganj central store |
| 66 | Return back balance material from site to LESA store daliganj. |
| 67 | Safe Loading, Carriage & unloading of following Materials from Centre Store to Pit Site/J.E. Dump Store & JE Dump store to work site |
| 68 | 11 KV VCB (OUTGOING ) 200/100/5A 350 MVA |
| 69 | DISMENTALLING OF 11 KV INDOOR TYPE OUTGOING PAINEL AT AMBEDKAR UNIVERCITY SUB STATION , |
| 70 | CARRIAGE OF OLD & USED 11 KV INDOOR TYPE PAINAL OF AMBEDKAR UNIVERCITY SUB STATION TO DALIGANJ CENTARL STORE DUMP YARD. |
| 71 | INSTALATION & COMMISIONING OF 11 KV INDOOR TYPE VCB OUTGOING PAINEL |
| 72 | CARRIAGE OF OLD & USED 11 KV INDOOR TYPE PANEL FROM AMBEDKAR UNIVERCITY SUB STATION TO DALIGANJ CENTARL STORE DUMP YARD. |
| 73 | Pipe boring type earthing minimum 20 meters deep from ground level or up to water level which ever comes first with \\"B\\" class G.I. pipe having 2\\" diameter, construction of chamber with cover for pipe type earthling, connecting bore type earthing with equipments with G.I. flat 50x6 mm by arc welding as per requirement in the switchyard as per department norms (material to be provided by the contractor) |
| 74 | Connecting earthing pipe to exposures of different 33 KV XLPE cable/C&R Panel with 25x6mm GI strp as per norms (material to be provided by the contractor) Please Enable Macros to View BoQ information |