| 1 | PART AProvision of Garden light in Mandal Kara Godda. |
| 2 | Supply of XLPE insulated sheathed (heavy duty) armoured electric cables with Aluminium conductor for working voltage 1100 volts conforming to IS:7098 (part-1)/IS:1554 |
| 3 | a) 2 core 6 sq, mm for garden light |
| 4 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm directr in ground including excavation, and refilling the trench etc as rquired, but excluding sand cushioning and protective covering. |
| 5 | S/F 40 mm dia, medium class G.I pipes for road crossing |
| 6 | S.I.T.C of following rating approved make LED Bollard fitting with rectangular shape of height 600 to 850mm power input-8/9watt with die cast aluminium housing opel with PC diffuser, IP:65/54 protection, conferming to IS:10322 part 5 etc all complete as required. (excluding plinth charge) (For Garden light.) |
| 7 | Making P.C.C. (1:2:4) plinth size of 1'x1'x1.5' including plaster and paint. |
| 8 | PART BReplacement of Security Light , Watch Tower light and street light on different ward Building in the campus of Mandal Kara Godda. |
| 9 | 7 Mtr. Height Octagonal Hot - Deep galvanized pole (BOP - 7030) with top dia 70 mm, bottom dia 130 mm & made of 3 mm thik sheet, base plate dimensions 200 x 200 x 12 mm (L x B x T) including suitable size of foundation bolt all complete as reqd. (Without Arm) |
| 10 | 1 mtr double arm suitable for 70 mm top |
| 11 | Installation, testing & commissioning of the 7 mtr. Octagonal pole & light fitting with the help of suitable tools and plants, and construction of shallow foundation with M25 grade concrete considering safe soil bearing capacity of 10T / mtrs sq. but excluding wire and MCB |
| 12 | S.I.T.C of floowing rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required |
| 13 | a)150W Street light on Building |
| 14 | b) 120w L.E.D light (on pole = 48 nos) |
| 15 | c) 200w L.E.D Flood Light on watch Tower |
| 16 | Supplying and fixing Cable junction Box with 6 amp SP MCB (Make - Sintex/Hensel or equivelant. |
| 17 | a) 63 Amp, double pole MCB ( for watch tower and different ward Lights controlling switch) |
| 18 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) |
| 19 | a) 2 way single door |
| 20 | supplying and drawing following sizes of FR PVC insulated copper conductor , single core cable in the existing surface /recessed Steel / PVC conduit as reqd. |
| 21 | a) 3x1.5 sq mm |
| 22 | Supplying and laying of XLPE insulated PVC sheathed aluminium armoured cable working voltage upto 1100 volts as per IS: 7098 (Part I) of following sizes. |
| 23 | a) 4 core 10 sq, mm. (for security light on pole) |
| 24 | b) 2 core 10 sq, mm. ( street light wiring on different wards Building) |
| 25 | c) 2 core 10 sq, mm. (Feeder Panel to watch Tower light wiring ) |
| 26 | d) 3.5 core 25 sq, mm. (Main Panel to Feeder panel) |
| 27 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including excavation and refilling the trench etc as reqd . But excluding sand cushioning and protective covering . |
| 28 | S/F 25 mm dia ISI marked PVC conduit standing of cable from tranch to junction box . |
| 29 | S/F 40mm dia med. Class G.I pipe for laying of cable in road crossing |
| 30 | S/F 6 to 32 Amps rating , 240 volts , \\"B\\" series , miniature circuit breaker suitable for lighting and other loads of following pole in the existing MCB DB complete with connections , testing and commissioning etc, as reqd . |
| 31 | Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 32 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required. |
| 33 | Fabrication and installation of wall mounted cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade including fitting / fixing / connection & transportation up to work site, labour charge etc all complete. (Double Door outdoor Feeder Panel) |
| 34 | 100 amps, MCCB 10 KA fixed thermal setting = 1 Nos. |
| 35 | 63 amp TPN MCB = 2 Nos |
| 36 | 63 amp DP MCB =5 Nos |
| 37 | 6 sq mm copper wire = 18 Mtr |
| 38 | LED Indecator lam R/Y/B/G = 3 Nos. |
| 39 | 25mm x 5mm copper strips (1.15 kg/mtr) = 18 Kg |
| 40 | PART CRepair of 1 nos old Highmast light in Mandal Kara Godda. |
| 41 | Feeder Pillar : control panel housing 63A TPN MCB incomer, single dial timer, 45A contactor circuit for the automatic control of luminaries power tool control with 2 no 9A contactors and raise lower push button, incoming 35sq.mm. and outgoing 16 & 2.5 sq.mm. terminals. |
| 42 | S/F 240 watt L.E.D Flood Light Make- Halonix, Havells, Bajaj, Surya, Crompton |
| 43 | S/F 3x2.5 sq mm copper insulated wire for highmast light wiring |
| 44 | S/F 6 mm SS wire rope |
| 45 | S/F EPR Copper Trailing cable for highmast light |
| 46 | S/F1.5 HP AC Motor |
| 47 | S/F Winch power tool for Single Drum |
| 48 | Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 49 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required. |
| 50 | Supply of XLPE insulated sheathed (heavy duty) armoured electric cables with Aluminium conductor for working voltage 1100 volts conforming to IS:7098 (part-1)/IS:1554(a) 4x10 sq mm |
| 51 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq. mm. direct in ground including excavation sand cushioning protective covering and refilling the trench etc. as reqd. |
| 52 | PART DReplacement of Main Service Cable, Different ward cable, Panel and Patch Repair of Electrical Installtion in Mandal Kara, Godda. |
| 53 | Wiring for circuit submain wiring along with earth wire with the following size PVC insulated copper conductor , single core cable in surface / recessed PVC conduit etc as reqd . |
| 54 | a) 2x1.5 sq mm + 1x1.5 sq mm Earth wire |
| 55 | b) 2x2.5 sq mm + 1x2.5 sq mm |
| 56 | Supplying and fixing of following size of PVC /G.I. Box on surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc as reqd. |
| 57 | a) 75mm x 75mm 50mm deep / (4''x4'') |
| 58 | b) 72mm x 146mm x 48mm deep / (4''x7'') |
| 59 | c) 121mm x 173mm x 48mm deep / (6''x8'') |
| 60 | d) 170mm x 221mm x 48mm deep / (8''x10'') |
| 61 | Supplying and fixing of following piano type switch / socket on the existing switch box / cover including connections etc as reqd. |
| 62 | a) 5/6 Amp, one way switch |
| 63 | b) 3 Pin 5/6 Amp, Socket Outlet |
| 64 | c) 15/16 Amp, 6 pin S.S combined |
| 65 | d) Electrinic Step Fan Regulator, mini |
| 66 | S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 67 | a) 20/22W LED Tube light |
| 68 | S/F 15 watt LED bulb |
| 69 | S/F 2 pin 5 Amp Ceiling rose on the existing junction box etc as reqd. |
| 70 | Supplying and fixing batten/ angle holder including connections etc as reqd. |
| 71 | S.I.T.C. of following size ceilling fan 3 blades confirming to IS:374:2019 including wiring the down roadsof suitable length (up to 30cm) with 1.5 sq. mm. PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as reqd. |
| 72 | a) 1200 mm (48'') ceiling fan |
| 73 | S/F 450 mm 1400 RPM Turbo Force heavy duty exhaust fan metal Body |
| 74 | Supplying and laying of XLPE insulated PVC sheathed aluminium armoured cable working voltage upto 1100 volts as per IS: 7098 (Part I) of following sizes. |
| 75 | a) 2 core 10 sq, mm. ( for Barrack and Guard Room) |
| 76 | b) 4 core 16 sq mm ( for Kitchen & V.C room) |
| 77 | c) 3.5 core 25 sq mm ( for Male ward & Female ward) |
| 78 | d) 3.5 core 70 sq mm ( Generator to Main Panel) |
| 79 | e) 3.5 core 120 sq mm ( Main service cable) |
| 80 | S/F 63/100 amp 4 pole 10 kA fixed thermal MCCB |
| 81 | S/F 125 amp 4 pole 35 kA fixed thermal MCCB |
| 82 | S/F 250 amp 4 pole 35 kA fixed thermal MCCB |
| 83 | S/F 125 amp 4 pole Changeover |
| 84 | S/F 200 amp 4 pole Changeover |
| 85 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including excavation and refilling the trench etc as reqd . But excluding sand cushioning and protective covering . |
| 86 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 95 sq. mm. but not exceeding 185 sq.mm direct in ground including excavation sand cushioning protective covering and refilling the trench etc. as reqd. |
| 87 | Fabrication and installation of wall mounted cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade including fitting / fixing / connection & transportation up to work site, labour charge etc all complete. (Main Double Door outdoor Feeder Panel) |
| 88 | 315 amps, MCCB 35 KA fixed thermal setting = 1 Nos. |
| 89 | 250 amps, MCCB 35 KA fixed thermal setting = 1 Nos. |
| 90 | 100 amps, MCCB 10 KA fixed thermal setting = 1 Nos. |
| 91 | 63 amp TPN MCB = 2 |
| 92 | 63 amp DP MCB =4 |
| 93 | Digital Volt Mtr. (0-500Volt)- 3 phase class 0.5 = 1 |
| 94 | Digital AMP Mtr. (0-500AMP)- 3 phase class 0.5 = 1 |
| 95 | C.T. Coil of C.T. Ratio 300/5 = 3 |
| 96 | LED Indecator lam R/Y/B/G = 3 Nos. |
| 97 | 50mm x 5mm copper strips (1.15 kg/mtr) = 27 Kg |
| 98 | Fabrication and installation of wall mounted cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade including fitting / fixing / connection & transportation up to work site, labour charge etc all complete. (For Different Ward and office Feeder Panel) |
| 99 | 100 amps, MCCB 10 KA fixed thermal setting = 1 Nos. |
| 100 | LED Indecator lam R/Y/B/G = 3 Nos. |
| 101 | 25mm x 5mm copper strips (1.15 kg/mtr) = 7 Kg |
| 102 | Fabrication and installation of wall mounted cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade including fitting / fixing / connection & transportation up to work site, labour charge etc all complete. (For Solar Panel ) |
| 103 | 250 amps 4 pole Changeover -1 |
| 104 | 63 amp TPN MCB = 4. |
| 105 | LED Indecator lam R/Y/B/G = 3 Nos. |
| 106 | 6 sq mm copper wire = 8 Mtr |
| 107 | 25mm x 5mm copper strips (1.15 kg/mtr) = 12Kg |
| 108 | CGST@% |
| 109 | CGST@% |
| 110 | Add Labour Cess@1% Please Enable Macros to View BoQ information |