| 1 | Excavation for structures ( Earth work in foundation of structures as per dawing and technical specifications , including setting out , construction of shoring and bracing ,removal of stumps and other deleterious matter, dressing in sides and bottom and backing filling with approved materials Ordinary soil as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 2 | Providing and laying concrete for plain / reinforcementconcrete 1:3:6 i/c cost of form work in open foundation complete a per drawig and technical specification : 802, 803 ,1202 and 1203.as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 3 | Providing and laying mechanically mixed and vibrated concrete in sub structure for all type of structure complete of plain cement concrete grade M-15 ( M fifteen) nominal mix 1: 2 ½ :5 ( One cement : two point five sand : five graded crushed/broken stone aggregate 40mm ( forty millimeter) nominal size in or under water and curing complete including pumping or bailing out water , dewatering removal of slush as required at site which may arise at the time of laying under water complete for all heights/ depths in Below/under approach slab including the cost of form work as per drawings and MORTH technical specification section 1500, 1700 and 2200 as per the entire satisfaction and as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 4 | Supplying, fitting and placing HYSD bar reinforcement in super structure complete as per drawing and MORTH technical specification section 1600 &2200 including cutting, bending, binding and placing in position complete in all respect including cost of binding wire upto any floor level as per the direction of the Engineer-in-charge including carriage of materials with in all leads & lifts. The rate are including of octrai, royality, malkana, toll tax, sale tax or other taxes imposed by the Govt. |
| 5 | Plain / reinforcement cement concrete sub structure complete a per drawing and technical specification :M 25 in abutment, Dirt wall Pier Caps etc vas per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 6 | Furnishing and placing reinforced / prestressed cement concrete M-30 in super structure as per drawing and technical specifications in Approach slabs, slabs etc as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 7 | Providing and laying cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and technical specifictions as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 8 | Contruction of pre-cast RCC railing of M30 grade, aggregate size not exceeding 12mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm leaving adquate space between vertical post for expansion , complete as per approved drawing and technical specifcations as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 9 | Drainage spouts complete as per drawing and technical specifications. as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 10 | Burrier providing and laying burried expansion joint being 20mm at both under thespan covered with 12mm thick 200mm wide galvanised weldable structural steel plated as per IS 2062 placed symmetrical to centre line of the joint , resting freely over the top surfce of the deck concrete welding of 800 dia 100mm long galvanised nails spced 300 mm c/c along the centre line of the pplate all as specified in clause 2604.as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 11 | Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 300 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 12 | Construction of Earthen Shoulders with approved material obtained from borrow pit with all leads and lifts, transporting to site, spreading, grading to required slope and capacity to meet requirement of table 300.1 and 300.2 with a lead upto 1000mtr as per technical specification clause 301.1 as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 13 | Construction of granular ub base by providing well graded materials, spreading in uniform layers with motor grader on prepared surface, mxing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density complete as per technical specifications clause 401 ( For grading -I materials ) as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 14 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam grade- II specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405 as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 15 | Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502 as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 16 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor @ 0.25 to 0.30 kg. per square meter on prepared granular surface treated with primer and cleaned with hydraulic broom as per as per Technical Specification Clause 503 as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 17 | Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade VG-10 to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508 as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. |
| 18 | Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade VG-10 and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 as per the directions of the Engineer-in-Charge, including carriage of materials within all leads and lifts and other incidental charges. The rates are includes of royalty, octroi, toll tax and all other charges as imposed by the Government but excluding G.S.T. Please Enable Macros to View BoQ information |