| 1 | Dismantling the old existing damaged RCC Wall upto 3.3m height including all labour charges etc., complete clearing away and carefully stacking materials useful for reuse etc complete |
| 2 | Clean removal of cement plaster from walls including cost of all labour charges etc complete |
| 3 | Dismantiling the Existing damaged weathering course including clearing away from the site etc complete |
| 4 | Earth work excavation for foundation in all kinds of soils and sub soils to full depth as directed by the departmental officers except hard rock requiring blasting inclusive of shoring strutting and balling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15cm thick well rammed and consolidated and depositing the surplus earth with in the compound in places shown by the departmental officers with initial lead of 10 meters and initial lift of 2 meters including clearing leveling the site etc., complete complying with standard specification (TNDSS No. 23, 24)- Drain and Culvert |
| 5 | Providing of Granular Sub base using Grade I materials of table 400 -1 of Morth with minimum CBR 30 spreading in uniform layers with motor grader on prepared surface, mix in by palce method at OMC and compacting with Vibratory Roller to achieve the desired density including all labourcharges etc, complete as per technical specification and as directed by the departmental officers. Morth - Rev V No. 111,112,401,900 |
| 6 | Plain Cement Concrete 1:5:10 (one part of cement, five part of Crushed Stone Sand (M- Sand) and ten part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 7 | Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification |
| 8 | Centering for soffits of RCC slabs plane surface including strutting upto 3.00m height using mild steel of size 90cmx60cmx10 gauge fitted with MS angle of size 25mmx25mmx3mm laid over silver oak (CW) joists of size 10cmx6cm spaced at 90cm c/c and supported by causrina props of 10cm to 13cm dia spaced at 75cm c/c complying with standard specification |
| 9 | a) Footing Sides |
| 10 | b) Vertical wall up to 0.90m Height |
| 11 | Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 12 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. |
| 13 | Supply and fixing of M.S Foundation Plate edge protection angle anf lifting hook with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. |
| 14 | Supply and Filling od Well Gravel from approved quarry including cost of loading unloading and lifting transportation chatges etc including cost of all labour charges for levelling and compacting etc complete |
| 15 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 16 | Paving the Top of roof with Solar refelective ceramic tiles of approved quality and colour laid in Cement mortar bed in 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with water resistant tile epoxy grout for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works) |
| 17 | Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 18 | Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with One coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 19 | Painting Old wood work with Two coat of synthetic enamel ready mixed paint of approved quality and colour in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 20 | Supply and Deliver and installation of Deck top computer-(Lenova / HP / Acer) to Following Component with Specification Component - SpecificationProcessor - Intel 12th Gen Core i7RAM - 8GBStorage - 1TB HDD (Hard Disk Drive)Ports - Minimum 4x USB 3.0/USB 2.0, 1x RJ-45 Ethernet (10/100/1000 Mbit)Operating System -Windows 8.1 Pro / Windows 10 Pro (64-bit) Monitor - 19-inch HD monitor (1366x768 resolution support)Peripherals - USB keyboard, USB optical mouse Rs -232 Serial to USB Converter ( Moxa, Modl Tybe : Uport1110) |
| 21 | Supply delivery and installation of HP P1108 LaserJet Pro Printer prints at speeds up to 18 pages per minute, and has a 250-sheet input tray. etc Complete |
| 22 | Supply delivery and Installation of 1Kva SINGLE PHASE UPS (Single Phase In & Single Phase Out) CAPACITY - APPROVERD MAKE SYSTEM WITH BATTERY - 2 HOURS BACK-UP etc complete |
| 23 | Wiringwith2x1.5sq.mm.PVCinsulatedSCunsheathedFRLScopperconductorof1100VgradeinsuitablePVCrigidpipeonwallandceilingwithPVCaccessoriesandwithTWswitchboxand5AFTswitchwithpaintingofsuitablecolourfor open PVC light point / fan point (for lectronic regulator) (5 points per coil) Sd-18 |
| 24 | Supplyandfixingof1200mm(48\\")ACceilingfancompletewithsteppedelectronic300Wregulatorwith300mmdownrod on the existing clamp Sd-110 |
| 25 | Supplyandfixingof3Nos.5A(3pinand2pin)combinedflushtypewallsocketwithcontrolswitchesconcealedinsuitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket) Sd-142 |
| 26 | Supplyandfixingof4FeetLED18WFittingwithLED18Wtube(LowerEnd)completewithTWroundblockson wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting (Sd-440) Please Enable Macros to View BoQ information |