| 1 | Day to day maintenance of feeder pillars and its accessories along with checking of pump sets as per inventory, terms and condition attached. |
| 2 | Lifting out of submersible pump set from the exiting bore well up to the required depth alongwith existing G.I. pipes and accessories etc. i/c dismantling of G.I pipe and disconnecting the sub. cable etc. complete as reqd. |
| 3 | Lowering & commissioning of sub. pump set in the existing bore well up to the required depth along with existing G.I pipe and sub. cable etc., water proof jointing of sub. cable, Replacement of reqd. nuts- bolts, washers and packing, nipple, reducer, connection, testing etc. complete as reqd. |
| 4 | Supplying/Replacement of PVC insulated copper conductor flat submersible cable of size 1 x 3 x 2.5 sq. mm i/c connection testing etc. compete as reqd. |
| 5 | Supplying and replacement of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame /floor etc complete as required :a) 40 mm dia. |
| 6 | b) 50 mm dia. |
| 7 | Repairing & rewinding of sub. motors of following capacity with cartage, dismantling, reassembling i/c supply & replacememt / repairing of damaged parts of motors and making good for operation i/c connection, testing, painting etc. complete as reqd.a) 3 HP to 5 HP, 3 Ph. sub motors. |
| 8 | b) Upto 2 HP, 3 Ph./1Ph. sub motors. |
| 9 | Repairing of sub. pump of the following stages & dia with cartage, dismantling, reassembling, supply & replacement / repairing of damaged parts of pump and making good for operation i/c testing, painting etc. complete as reqd.a) Upto all stages 6\\"dia submersible pump sets |
| 10 | b) Upto all stages 4\\" dia submersible pump sets |
| 11 | Supplying & replacement of following control gear / accessories in the existing installation for electric panel boards, motor starters, connection, testing etc. as reqd.a) 63 AMP FP MCB (C -Series). |
| 12 | b) Single phase preventor with auto-reset feature |
| 13 | d) 32 AMP TP MCB (C-Series). |
| 14 | e) 0-30 AMP Ammeter (96mm x 96mm square dial flush mounted) |
| 15 | f) 0-500 Volt Voltmeter(96mm x 96mm square dial flush mounted) |
| 16 | g) DOL Starter suitable up to 7.5 HP pump set with relay range 9-14 amp. |
| 17 | h) Thermal Overload relay with range 9-14 amp.. |
| 18 | i) No volt coil, for up to 7.5 HP DOL Starter. |
| 19 | j) Contactor block for up to 7.5 HP DOL Starter. |
| 20 | k) 4 Pole FPMCCB 100 Amp. 30 K.A |
| 21 | l) 4 Pole FPMCCB 250 Amp. 36 K.A |
| 22 | Taken out of fallen & stuck sub. pump set from the existing bore well up to all depth along with sub. cable, G.l Pipe etc. complete as reqd. |
| 23 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.a) 4 X 25 sq. mm,DSR |
| 24 | Supplying of following size XLPE insulated & PVC sheathed, aluminum conductor armoured power cable of 1.1 kV grade, connection testing etc. as reqd.a) 4 x 25 sq mm. |
| 25 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Upto 35 sq. mm,DSR |
| 26 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, refilling the trench etc. as required, but excluding sand cushioning and protective covering. a) Upto 35 sq. mm,DSR |
| 27 | Repairing of existing feeder pillar i/c replacment of 2 mm thick CRCA sheet in front / side door with welding of hinges, gasketted cover, handle, locking arrangement painting with both sides etc as reqd. |
| 28 | Supplying and Replacement of 3Phase 415 Volts DOL submersible pump starter compact panel with 3 position selector switch, volt meter, ammeter, single phase preventor premium with short circuit protection and C-curve T.P. MCB with suitable relay range upto 5.5 H.P. pump set, connection testing, commissioning etc. complete as reqd. |
| 29 | Repairing of existing wiremesh protection frame including supplying & fixing of 8 SWG M.S. wiremesh (of size 75mm x 25mm) with M.S. angle iron base frame (of size 35mm x 35 mm x 5 mm), cutting, welding, painting, making locking arrangement etc. complete as reqd. |
| 30 | Additional lowering of existing G.I pipe with existing lowered submersible pump set up to the required depth including jointing of existing submersible cable, socket, nuts -bolts, rubber packing etc., jointing of delivery line etc. complete as reqd. |
| 31 | Digging out of 1 No. faulty PVC insulated, PVC sheathed/ XLPE power cable laid in gound and relaying of the same after removing of the cable fault i/c refilling and redressing of the trench etc. as reqd. |
| 32 | Hire charges for cable fault locating machine to locate the fault in the existing underground LG cable etc. as reqd. |
| 33 | Dismantling , repairing and rewinding of 60 HP, 3 Phase, 415 Volt Induction Motor Kirloskar Make i/c supply & replacement of ball bearing - 2 Nos. (6312), connection plate, fan cover, varnishing, baking , cartage to & fro, painting, re- installation at site, testing etc. complete as reqd. |
| 34 | Dismantling, servicing & refixing of Sewage treated water pump set kirloskar make Suitable for 60 HP Induction motor i/c dismantling of impeller, shaft sleeve, ball bearing and supply & replacement of ball bearing- 2 Nos. size 6309, re-metaling of pump shaft i/c turning and grinding, providing & fixing SS Shaft sleeve, gland plate, gland stud, gland packing, cartage to & fro, re- installation at site, painting, testing & commissioning etc. complete as reqd. |
| 35 | Supplying & fixing of 60 HP manually operated oil immersed star- delta motor starter with double contact i/c starter oil for 3 phase, 415 V, 1450 RPM induction motor and connection, testing etc. complete as reqd. |
| 36 | Repairing & Rewinding of 1 HP sewage sbmersible pumpsets for dewatering including suplying & replacement of Mechanical seal, suitable ball bearing, including supply & Replacement 'O' ringset, Lubricant oil complete as required. |
| 37 | Supplying and replacement of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a)250 A, 25kA, TPMCCB, DSR 2025 item: 2.2.6 |
| 38 | b) 400 A, 50kA, FPMCCB, DSR 2025 item: 2.2.18 |
| 39 | Lifting out of pump set from the existing UGRs including dismantling of G.I. Pipe delivery line, and sub. Cable and lowering of same pump set along with G.I. Pipe and sub. Cable after repairing of pumpset, jointing of cable, testing etc. Complete as required. |
| 40 | Dismantling, repairing and rewinding with copper wire of 3 HP,415 volt sewage (CETP) treated water pumpset i/c motor ,cartage charges to and fro, supplying & replacement of mechanical seal and oil seal, radial ball bearing upper and lower side, cable seal, mobile oil for lubrication of seal, 'O' ring set , etc complete , connection testing as required. |
| 41 | Supplying & replacement of sewage treated water submersible pumpset duly coupled with suitable rating 3 phase , 415 volt, 50 Hz, 3000 RPM Submersible Motor .The pumpset shall be suitable for following duties:-i)Capacity : 3 HPi)Discharge : 640-100 LPMii) Head Range :10-18 mtriii)Liquid: Sewage/CETP wateriv)Solid handling Capacity : 35 mm |
| 42 | Supplying, Replacement (Dismantling the existing feeder pillar if any ), testing and commissioning of floor mounted L.T. feeder pillar (meter panel) cubical type double door of size 1000 mm x 900mm x 400 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasketted covers and screwed knobs with double locking arrangement and rain protection covers 100 mm, supported with MS angle iron legs and bottom frame of size 40mm x 40mm x 6mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections , inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required (as per drawing approved by Engineer-in-charge) .(a) Incomer100 Amps. 4 pole MCCB, 30 K Amp.--1No. (b) Neutral link - 2 nos. (c) 63 Amps. FP MCB ('C'-Series)------4 Nos. (d) Danger notice plate -----1 No (e) Lifting hook on the top of feeder pillar ---1Set.(f) AI. Bus Bar 250 amp. 4 strip, 300 mm long with sleeve and nut bolts-----1 Set.(g) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.(h) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.(i) Phase Indicating Lamp Set with fuses ----1 Set (j) Suitable space for energy meter alongwith bakelite sheet ---- 1 no.(k) RCCB 100 A, Sensitivity 100 mA --- 1 no. |
| 43 | Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (pump panel) cubical type double door of size 1000 mm x 900mm x 300 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasket covers and screwed knobs with double locking arrangement and rain protection covers (100 mm), supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required(as per drawing approved by Engineer-in-charge) .(a) 100 Amps. 4 pole MCCB, 36 K Amp.--1No. (b) 3 phase DOL submersible pump starter & C-Curve TP MCB with suitable relay range of 09 to 14 Amp. --- 1 Set. (c)32A DP MCB, 10 KA, C series -1 no. (d) 32A TP & N MCB (C-series)----2 No. (e) Danger notice plate -----1 No (f) Lifting hook on the top of feeder pillar ---1Set. (g) AI. Bus Bar 100 amp. 4 strip, 300 mm long with sleeve and nut bolts-----1 Set.(h) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.(i) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.(j) Phase Indicating Lamp Set with fuses ----1 Set |
| 44 | Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (pump panel) cubical type Single door of size 500 mm x 500mm x 400 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasket covers and screwed knobs with double locking arrangement and rain protection covers (100 mm), supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required(as per drawing approved by Engineer-in-charge) .(a) 125 Amps. 4 pole MCCB, 36 K Amp.--1 no.(b) Backelite sheet for energy meter installation - 1 no. |
| 45 | Supplying and replacement of submersible pumpsets (water filled motor) operating on 3 phase, 415 Volts, 50 Hz of following specification including lifting of dismantle Pumpset & Lowering of new submersible pump set in the existing bore well up to the required depth alongwith existing G.I. pipes and sub. Cable etc. water proof, jointing of sub. cable, Replacement of reqd. nuts- bolts, washers and packing, nipple, reducer, connection, testing etc. complete as reqd .a) Approximate Head Range (m)-33 ft -403 ftb) Approximate Discharge Range (L / min)-50 L / min - 230 L / min c) Capacity – 5 HP d) No. of stages - 25e) Delivery Size- 50 mm |
| 46 | Supplying, Fabrication and replacement of wire mesh protection frame for existing feeder pillar made out of 8 SWG M.S wire mesh size (75mm X25mm rectangle nominal) of following size with base frame made of M.S angle iron 35mm x 35mm x 5mm and with M.S strip support of size 35mm X 5mm in cross and 0.5 mtr long legs support of same angle iron (as per drawing attached) , i/c door in front portion, supplying and fitting of godown lock i/c locking arrangement, painting and grouting of angle iron frame with legs in CC 1:3:6 foundation etc. as approved by Engineer incharge etc. complete as reqd.a) 2 mtr (H) X 1.5mtr (W) X 1.0 mtr (D) |
| 47 | Supplying & replacement of impellar for the existing STP booster pump sets suitable for the 40/50/60 HP induction motor i/c supplying & fixing of fastner, nuts, bolts,keys etc. required for fixing the impellar including testing & commissioning etc . complete as required |
| 48 | Repairing of existing oil immersed star delta starter i/c replacement of faulty over load coil, brass finger and fixing with new thimble, SS nut bolt, filling of oil etc. complete as required. |
| 49 | Supplying and drawing of size 16 sqmm, 1.1 KV grade, FRLS PVC insulated copper conductor single core cable in the existing surface/ recessed/conduit including connection, testing etc. complete as required |
| 50 | Supplying and replacement of vertical lift check valve madeuo of gun metal having size of 50 mm including S/F of thread , connection, testing etc complete as required |
| 51 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 52 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information |