Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE 'A' PART-I to SCHEDULE 'A' PART-XIII:Note: Schedule 'A' Part-I to Part-XIII are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only. |
| 2 | Lump Sum price worked out by the contractor for 'Buildings & Structures' as listed in Schedule 'A' Part-I. |
| 3 | Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation as listed in Schedule 'A' Part-II. |
| 4 | Lump Sum price worked out by the contractor for 'Pile Foundation' as listed in Schedule 'A' Part-III. |
| 5 | Lump Sum price worked out by the contractor for 'Internal Water Supply' as listed in Schedule 'A' Part-IV. |
| 6 | Lump Sum price worked out by the contractor for 'Internal Electrification' as listed in Schedule 'A' Part-V. |
| 7 | Lump Sum price worked out by the contractor for 'External Water Supply' as listed in Schedule 'A' Part-VI. |
| 8 | Lumpsum price worked out by the contractor for 'External Electrification' as listed in Schedule 'A' Part-VII. |
| 9 | Lump Sum price worked out by the contractor for 'Area Drainage' as listed in Schedule 'A' Part-VIII. |
| 10 | Lump Sum price worked out by the contractor for 'Sewage Disposal' as listed in Schedule 'A' Part-IX. |
| 11 | Lump Sum price worked out by the contractor for 'Lightening Protection' as listed in Schedule 'A' Part-X. |
| 12 | Lump Sum price worked out by the contractor for 'Road/Path/Culvert', as listed in Schedule 'A' Part-XI. |
| 13 | Lump Sum price worked out by the contractor for 'Fire Fighting System' as listed in Schedule 'A' Part-XII. |
| 14 | Lump Sum price worked out by the contractor for 'Fire Alarm' as listed in Schedule 'A' Part-XIII. |
| 15 | SCHEDULE 'A' PART-XIV (MISCELLANEOUS ITEMS):PILE FOUNDATION , ROAD /CULVERT, AREA DRAINAGE, SEWAGE DISPOSAL, INTERNAL WATER SUPPLY, INTERNAL ELECTRIFICATION , LIGHTENING PROTECTION COOLING APPLIANCES, TV & TELEVISION, CHEMICAL EARTHING , AIR CIRCULATORS, AVIATION LIGHT, EXTERNAL WATER SUPPLY, EXTERNAL ELECTRIFICATION, FIRE FIGHTING SYSTEM, FIRE ALARM, DG SET,EOT CRANE, |
| 16 | SITE CLERANCE AND DEVELOPMENT |
| 17 | Crusher dust filling in floor or pavings laid in layers not exceeding 15cm thick spread levelled and rammed including watering and rolling complete all as specified and as directed. |
| 18 | supply and fixing high non wooven poly propylene geotextile having minimum weight 285 gm per sqm (confirming to clause 702, table 700-5 of morth 5th revision) complete all as specified. |
| 19 | PILE FOUNDATION |
| 20 | Boring for bored cast-in-situ piles 500mm dia. in SDR/any type of rock and getting and disposal of spoil out side MD land using Hydraulic/DMC system of boring method complete all as specified and as directed. |
| 21 | Boring for bored cast-in-situ piles 500mm dia. in any strata except SDR/hard rock and getting and disposal of spoil out side MD land using Hydraulic/DMC system of boring method complete all as specified and as directed. |
| 22 | Carrying out initial load [Compression] test on 500mm dia. pile complete all as specified and as directed. |
| 23 | Carrying out initial load [Lateral] test on 500mm dia. pile complete all as specified and as directed. |
| 24 | Carrying out Routine load [Compression] test on 500mm dia. pile complete all as specified and as directed. |
| 25 | Carrying out Routine load [Lateral] test on 500mm dia. pile complete all as specified and as directed. |
| 26 | MS pipe liner fabricated out of 6mm thick plain MS plate confirming to Fe-410S by welding the joints lengthening wherever required, providing stiffener, lifting hooks including all as T&P as required, shifting the same from positions required, driving in true vertical alignment in position to the required level for piles complete all as directed by Engr-in-charge.NOTE: MS Pipe liner shall be casted as mentioned in drawing. however for payment purpose, the depth of pile liner shall be measured upto cutoff level irrespective of the depth provide for retaining concrete/Bentonite slurry. The unit rate/lumpsum price quoted shall be deemed to included for the same. |
| 27 | INTERNAL WATER SUPPLY: |
| 28 | Supply and fixing of Bib taps two way, fancy type screwed down for size of 15 mm inner dia, suitable for 16 mm outer dia CPVC pipes complete all as specified and as directed. |
| 29 | Supply and fixing of health faucet chromium plated , fancy type with steel flexible complete of size of 15 mm dia suitable for 16 mm dia outer dia CPVC pipes complete all as specified and as directed. |
| 30 | S & F Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed 15 mm inner dia suitable for 16 mm dia outer dia CPVC pipes complete all as specified and as directed. |
| 31 | S & F Urinal water dropper, chromium plated , fancy type ,suitable for 15mm angle valve/16 mm dia outer dia CPVC pipes complete all as specified and as directed. |
| 32 | INTERNAL ELECTRIFICATION |
| 33 | Material and Labour for Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly One light point controlled by one switch complete all as specified and as directed. |
| 34 | Material and Labour for Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly One fan (ceiling fan/exhaust fan/wall mounted/ air circular fan) point controlled by one switch complete all as specified and as directed. |
| 35 | Material and Labour for Point wiring with 2.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 2 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly One 3 Pin socket outlet 6 Amps socket on independent board complete all as specified and as directed. |
| 36 | Material and labour for Point wiring with 4 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 4 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly one 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity. |
| 37 | Material and Labour for Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly one light point controlled by two Nos. two way switches complete all as specified and as directed. |
| 38 | Supply and fixing ceiling fan complete with blades, down rods, electronic regulator modular type, and accessories, 230 V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.0 BEE five star rated with brushless direct current motor (BLDC) with and including flexible copper wire 1 sqmm form ceiling rose to connector of ceiling fan complete all as specified and as directed. |
| 39 | Supply and fixing Exhaust fan made out of sturdy engineering plastic complete with louvers shutter, 230 Volt, 50 Hz, RPM 1200 copper winding of sweep 250 mm . fixed on wall making opening, fixing and making good the disturbed surfaces etc. complete with and inclusive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as specified and as directed. |
| 40 | Supply and fixing Exhaust fan AC single phase 230 Volt of size 300 mm sweep, steel body with blades, and frame and louvers fixed on wall making opening, fixing and making good the disturbed surfaces etc. complete with and inclusive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as specified and as directed. |
| 41 | Supply and fixing Exhaust fan AC single phase 230 Volt of size 450 mm sweep, steel body with blades, and frame and louvers fixed on wall making opening, fixing and making good the disturbed surfaces etc. complete with and inclusive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as specified and as directed. |
| 42 | S & F, Wall mounted fan AC single phase 230 Volt of size 400 mm sweep with three blades & inbuilt regulator and frame fixed on wall and making good the disturbed surfaces etc. complete with and inclusive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as specified and as directed. |
| 43 | Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x1.5 sqmm for phase and neutral duly colour coded and 1x1.5 sqmm for earth continuity conductor green in colour complete for one 450 mm sweep exhaust fan point controlled by one 06 amps modular switch all as specified and as directed. Note: Modular switches, switch plate and switch box shall be measured separately. |
| 44 | Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall/drawn along with truss, and PVC wire of size 2x1.5 sqmm for phase and neutral duly colour coded and 1x1.5 sqmm for earth continuity conductor green in colour complete for two Nos High bay light point controlled by one 06 amps modular switch all as specified and as directed. Note: Modular switches, switch plate and switch box shall be measured separately. |
| 45 | Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall/drawn along with truss, and PVC wire of size 2x2.5 sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete for three Nos High bay light point controlled by one 15 amps modular switch all as specified and as directed. Note: Modular switches, switch plate and switch box shall be measured separately. |
| 46 | Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x2.5 sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed. |
| 47 | Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x4 sqmm for phase and neutral duly colour coded and 1x4 sqmm for earth continuity conductor green in colour complete all as specified and as directed. |
| 48 | Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x6 sqmm for phase and neutral duly colour coded and 1x6 sqmm for earth continuity conductor green in colour complete all as specified and as directed |
| 49 | Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 4x6 sqmm for phase and neutral duly colour coded and 1x6 sqmm for earth continuity conductor green in colour complete all as specified and as directed. |
| 50 | Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 4x10sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed. |
| 51 | Supply and fixing energy efficient LED ultra modern recessed mounting luminaire with high performance square type of size approx 2 feet x 2 feet, 40/42 watts, 240 volts, 50 Hz including making necessary electrical connection from ceiling rose/ PVC connector complete all as specified and as directed |
| 52 | Supply and fixing Energy efficient LED tube light fitting with tube 9 watts, lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and as directed |
| 53 | Supply and fixing Energy efficient LED tube light fitting with tube 10 watts ,240V, 50hz surface mounted, with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and as directed |
| 54 | Supply and fixing Energy efficient LED tube light fitting with tube 20 watts or nearest size ,240V, 50hz surface mounted, with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and as directed |
| 55 | Supply and fixing LED high bay light fitting IP 65 Energy efficient , environment friendly & robust IP 65 protected LED midbay with PDC housing suitable for ceiling (surface/suspended) mount & available in wide beam optics of 50 watts complete with mounting bracket etc. including connecting up all as specified and as directed |
| 56 | Supply and fixing LED medium bay/high bay light fitting IP 65 Energy efficient , environment friendly & robust LED luminaire with high efficiency with toughened glass of 100 watts suitable for ceiling (surface/suspended) mount complete with mounting bracket etc. including connecting up all as specified and as directed |
| 57 | Supply and fixing LED medium bay/high bay light fitting IP 65 Energy efficient , environment friendly & robust LED luminaire with high efficiency with toughened glass of 120 watts suitable for ceiling (surface/suspended) mount complete with mounting bracket etc. including connecting up all as specified and as directed |
| 58 | Supply and fixing LED Security light fitting 30W New generation Energy saving &environmental friendly long life made up of pressure die cast aluminium housing with high efficient LED as lighting source and lens embedded PC cover having bottom opening separate driver compartment with IP66 protection pre wired and connecting up upto connector including 1.5 m long GI Tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc. complete all as specified and as directed. |
| 59 | Material and labour for wall/floor mounted LT Panel board made out of CRCA sheet 2 mm thick indoor , CPRI approved, totally enclosed with front opening, hinged doors, compartmentalised, weather and water proof with necessary locking arrangements along with lugs, danger notice plate, cable glands, stickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc. used are to be made of rust proof material incl Aluminium bus bar duly covered with heat proof colour code, insulators suitable for three phase and neutral LT AC, 50 Hz 415 V, 400 A capacity, complete with powder coated painting, necessary internal electric connection with suitable size coper wire, fitted with and inclusive following items: |
| 60 | INCOMING :(a) MCCB 4 Pole, 415 V, Adjustable type variable range, 250 Amps, with O/L and short circuit protection, breaking capacity 25 kA - 01 NoOUTGOING :(a) MCCB 4 Pole, 415 V, 63 Amps with breaking capacity 16 kA - 01 Nos (b) MCCB 4 Pole, 415 V, 40 Amps with breaking capacity 16 kA - 09 Nos (01 spare)(c) MCCB 4 Pole, 415 V, 32 Amps with breaking capacity 16 kA - 05 Nos (01 spare)(d) MCP SPN 32 Amps, 240 Volt \\"C\\" curve - 09 Nos(e)Volt meter with selector switch 0 to 415 Volt - 01 No(f) Ammeter with selector switch and CTs 0 to 250 Amps - 1 No(g) LED phase indicator lamp for R Y B phases- 16 set |
| 61 | M&L for earthing complete with galvanised steel plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI strip of 25mm x 4mm by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe light grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto panels, and suitable CI top cover with handle, funnel, strainer, charcoal, salt and testing on completion all as specified and as directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC work complete all as specified and as directed. |
| 62 | M&L for earthing complete with galvanised steel plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI wire 4mm dia by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe light grade for watering pipe and 15 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer, charcoal, salt and testing on completion all as specified and as directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC work complete all as specified and as directed. |
| 63 | COOLING APPLIANCES |
| 64 | Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having nominal cooling capacity 40 litres/hour and storage capacity 80 ltr complete all as specified and as directed. |
| 65 | Supply and fix water cooler electric driven (single phase), having approx. storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour all as specified and as specified and as directed. |
| 66 | Supply and installed Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 kVA |
| 67 | TV & TELEVISION |
| 68 | Supply and fix factory fabricated GI metal flush boxes suitable for 2 module complete all as specified and as directed. |
| 69 | Supply and fix RJ 11 telephone socket 1 module with cover plate complete all as specified and as directed. |
| 70 | Supply and fix TV socket 1 module with cover plate complete all as specified and as directed. |
| 71 | M&L Rigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., dia. of conduit 20 mm all as specified and as directed |
| 72 | M&L Rigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., dia. of conduit 25mm all as specified and as directed. |
| 73 | Supply and fixing/drawing PVC insulated telephone cable one pair on existing PVC conduits concealed to wall, of make Havells or equivalent make Note :PVC conduit shall be measured separately. |
| 74 | Supply and fixing/drawing of CATV co-axial cables (Electrolytic grade solid annealed copper conductor, jelly field, Aluminium foiled and aluminium wire braided) of Havells make or any other equivalent make Note :(i) PVC conduit shall be measured separately .Note :Prior to drawing of telephone conduits/TV conduits, the contractor shall take necessary approval of diagram from Engr-in-Charge. |
| 75 | Supply and fix PVC junction box 20 mm complete all as specified and as directed. |
| 76 | Supply and fix PVC junction box 25 mm complete all as specified and as directed. |
| 77 | CHEMICAL EARTHING |
| 78 | Material and labour for Chemical Earthing complete with copper earth plate electrode 90 cm x 60 cm x 5 mm thick buried directly in ground to a depth not less than 2.25 metre below normal ground level connected to copper strip of 32 x 6 mm earth lead with GI protection pipe 75 mm dia light grade connected to test point terminal block by means of bolts, nuts and washers of copper all as shown on plate No 3 of SSR Part-I to the extent applicable to this item including necessary excavation earth work PCC chamber in 1:3:6 type of C1 RCC cover slab, lifting handle, watering pipe of GI 20mm dia light grade, funnels wire mesh, chemical PRO-CEM and earth enhancing mineral compound meeting the requirement \\"As PER is - 3043\\" etc. testing on completion complete all as specified and as directed.. |
| 79 | Supply and fixing of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to pole or any other indicated situation for loop earthing etc. as required for copper strips 32 X 6 mm with proper saddles / spacer, screws etc. all as directed. |
| 80 | Supply and fixing steel tubing of light grade, galvanised, with all fittings and fixed complete to wall and ceiling or laid in floors of 40 mm bore complete all as specified and as directed. |
| 81 | AIR CIRCULATORS |
| 82 | Supply and install Air circulator fans dia 24 inch, 230 volts, 50 Hz, 1440 rpm,15000 CMH, single phase oscillating 600 mm sweep having 3 no of blades, with aluminium front and back false cover, high torque cast iron gear box with safety clutch, max temp rise 52 degC, suitable for wall mounting with all necessary arrangement all as specified and as directed. |
| 83 | AVIATION LIGHT |
| 84 | Supply and fix aviation obstruction light LED type 10 Watt including standard fixing arrangements complete all as specified and as directed. |
| 85 | Supply and fix cable PVC insulated armoured PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor laid in ground fixed to wall roof etc. with suitable clamps spacers bolts nuts etc. all as specified and as directed |
| 86 | Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure all as specified and as directed. |
| 87 | EXTERNAL WATER SUPPLY |
| 88 | Material and Labour for valve chamber of internal size 750x750x750mm comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm below GL,100mm thick PCC 1:3:6 type B1 as in copings,3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as specified and as directed. |
| 89 | Material and labour for Cutting existing 150 mm steel tubing for alterations or additions necessarily done in position without taking down and inserting Tee of 150 x 150 x 80 mm for tapping all as specified and as directed.(Tapping point shown) |
| 90 | EXTERNAL ELECTRIFICATION |
| 91 | Supply and fix lightning arrestor HT 11 KV 10 KA station class complete all as specified and as directed. |
| 92 | Supply and fix HT 11 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complete with drop out fuse having 12 insulators of rating upto 400 Amps complete all as specified and as directed. |
| 93 | Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor 3.5 core 300 Sqmm |
| 94 | Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor 3.5 core 70 Sqmm |
| 95 | Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor 3.5 core 35 Sqmm |
| 96 | Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor 4 core 16 Sqmm |
| 97 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm. |
| 98 | Supply, installation, testing and commissioning of LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc. used are to be made of rust proof material incl as per IS: 8623 tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 800 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: |
| 99 | INCOMING:(a)MCCB 4 Pole, 415 V, 36 KA(ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 400 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 01 No.OUTGOING:a)MCCB 4 Pole, 415 V,36 kA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 250 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes. - 02 Nos.(01 for bldg. and 01 spare)b) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 125 A capacity 25kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 Nos.(AC Plant Panel and spare)c) MCB SPN 'C' curve 32A , 415 V, 50 Hz - 02 Nos (street lights and spare)d) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 63 A capacity 25kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 Nos.(01 for crane and spare) |
| 100 | e)Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc. with all connected CTs of each breakersf) Timer switch with control relay/contactor - 01 Nog) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers |
| 101 | Supply, install, testing and commissioning of factory made APFC panel CPRI approved OEM, free standing floor mounted, dust and vermin proof with harmonic filter, Automatic Power Factor Correction [APFC] Panel of capacity of 60 KVAR with 2 steps (2 x 30) Compartmentalised, indoor type, fabricated as per IEC 61921 with 2 mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces with minimum IP 43 Ingress Protection suitable for 3 Phase, 415 V & 50 Hz System with MD-XL Capacitor including suitable rated TPN, MCCB, 415 V, 35 KA rupturing capacity as incomer duly controlled by Auto and Manual option including instrumentation such as Power Factor Meter – 1 Nos, Digital type Ammeter of Range 0 to 250 Amps with CTs & Selector Switch – 1 Nos, Digital type Volt Meter of Range 0 – 500 V – 1 Nos, Relay, Auxiliary Contacts, CTS, Phase Indicating LED Lamps [RYB], Selector switches etc., |
| 102 | suitable internal wiring with copper cable of suitable size, double stud hinged door, front openable with locking arrangement including interlocking with switch gears complete and panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level including connecting up with existing incoming and outgoing cables etc. complete all as specified and as directed. |
| 103 | Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering including tested on completion complete all as specified and as directed. |
| 104 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 160 mm dia suitable for 0.4 mpa working pressure as directed. |
| 105 | Supply & install steel tubular swaged poles Type 410 SP-31 (9.0 metres long) complete with CI base plate and finial and single swan neck including foundation(12 for street light, 03 for solar street lights) all as specified and as directed. |
| 106 | Supply and fixing LED street light fitting 35/36 W 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and as directed. |
| 107 | Supply and fix Loop in loop out box (minimum size-200mm x 160mm x 98mm)of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc. all as specified and as directed. |
| 108 | Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 50 Volts per second and of capacity 25 KVA complete all as specified and as directed. |
| 109 | M & L for PVC insulated copper conductor of size 2.5 sqmm 3 core drawn through PVC pipe with clamping materials complete all as specified and as directed. |
| 110 | M & L earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 metres below normal ground level, connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. |
| 111 | M & L for steel tubes, 'light grade', galvanised, 32 mm bore with all fitting bend to shape fixed to pole with one set of clamps of appropriate size all as specified and as directed. |
| 112 | M & L for sub main wiring with 4 runs of single core 16 Sq.mm, single core , FRLS, PVC insulated, unsheathed, Multistranded copper conductor cable, 1100 volts, FRLS grade, ISI marked, for phase and neutral duly colour coded drawing through and including medium duty PVC conduit, 32 mm dia with all accessories concealed in walls/ roofs/ floors / ceiling etc. including one run of 16 Sqmm single core, FRLS PVC insulated, unsheathed, Multistranded copper conductor cable, 1100 volts, FRLS grade earth continuity conductor complete all as specified. Note: 4 runs of 16 Sqmm, 1 runs of 16 sqmm & one run 32 mm dia PVC conduit will be measured as one unit. |
| 113 | Supply and fix danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. Clamps, bolts and nuts of approved size, for HT, 25x20 cm size all as specified and as directed. |
| 114 | Supply and installation, testing and commissioning of distribution tranformer step down, outdoor type, 11/0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changinr arrangement on HT side for a variation of secondary voltage +/- 7.5% insteps of 2.5% continous rating of 200KVA outdoor type confirming to IS 1180 (level-II) with and including the following:(a) Lifting lugs/ hooks for transformernand tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug(e) Drain outlet pipe with brass gate valve with dummy plug.(f) Conservator with level gauge.(g) Silica gel breather.(h) First oil fill up upto the recommended level by manufacturer with new oil conforming to IS 335.(j) Type of connection : ONAN(k) Vector Group : DYN 11.(l) Type connecting arrangement: Cable termination boxes on both HT and LT side.(m) Temperature rise over an ambient of 50°C maximum.(n) All necessary arrangements with devices for measuring the temperature of core, winding and oil.(o) In addition to the above all standard fittings shall be provided as per IS norms. |
| 115 | AREA DRAINAGE |
| 116 | Removal of excavated soil to a distance exc 250m and not exc 500m and depositing where directed at a level n.exc 1.5m above starting point complete all as specified. |
| 117 | SEWAGE DISPOSAL |
| 118 | Supply and Fixing for SFRC manhole cover slabs MD 10 Rectangular (for manhole) with plain faces set in Cement motar 1:4 complete all as specified. |
| 119 | LIGHTENING PROTECTION |
| 120 | Material and Labour for Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering including testing on completion complete all as specified and as directed. |
| 121 | ROAD /CULVERT |
| 122 | Material and Labour for painting lines, dashes, arrows, letters etc. on roads pavements and the like n.exc 10 cm wide with road marking paint , white or golden yellow complete all as specified as directed. |
| 123 | FIRE FIGHTING SYSTEM |
| 124 | Supply and lay ductile Iron flanged pipe, including specials, Class “K-9” ,150 mm (6”) dia conforming to IS-8329 in standard length suitable for push on rubber gasket complete all as specified and as directed. |
| 125 | Material and labour for Cutting existing F/F pipe line for alterations or additions necessarily done in position without taking down and inserting Tee of 150 x 150 x 150 mm for tapping all as specified and as directed. |
| 126 | FIRE ALARM |
| 127 | Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and as directed. |
| 128 | Supply and fix LED EXIT light double sided with battery back up up to 2 Hrs. of operating voltage 230 V, 50 Hz complete with all as specified and as directed. |
| 129 | DG SET |
| 130 | Silent engine generating set with accoustic enclosure as per CPCB norms 415 volts 200 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:- Please Enable Macros to View BoQ information |
| 131 | Silent engine generating set with accoustic enclosure as per CPCB norms 415 volts 200 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:- Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy