| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority:Executing Agency, NWM&M, HQ IDS Name of Work :Provn of Hardstanding and Pathway Around Inverted Rifles & Helmet in Param Yodha Sthal at National War Memorial Contract No: PD/EANWMM/……./2026-2027 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE 'A' (BoQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Surface Excavation exc 30 cm deep and averaging 15 deep and getting out soft and loose soil, complete all as specified and as directed by Dy Project Director. |
| 3 | Excavation in trenches not exceed 1.5m wide and not exceed 1.5m in depth for foundation etc in soft / loose soil, complete all as spcified and as directed by Dy Project Director. |
| 4 | Returning filling including spreading levelling, watering and well ramming in layer not exceed 25cm thick in soft/loose soil, complete all as specified and as directed by Dy Project Director. |
| 5 | Removing excavated material exc 50m and not exc 500m and depositing where directed at a level n exc 1.5m above the staring point complete all as specified and directed by Dy Project Director. (Note:- The excavated material shall be dipoesd out of the National War Memorial Premises.) |
| 6 | M&L for Hardcore of gauge n exc 63mm brocken stone of boulders deposited,spread and levelled in layer n exc 10mm thick, watered and rammmed to true surface all as specified and directed by Dy Project Director. |
| 7 | M&L screed bed or bedding layer 20mm thick of cement mortar 1:4 for laying 20 thick granite stone complete all as specified and as directed by Dy Project Director. |
| 8 | Providing and Laying 150mm thick cement concrete 1:2:4 type (using 40mm graded crushed stone aggregate) as in sub-floors, below paving etc, including necessary use and waste of form work / screed strips and also including finishing the top surface of concrete even and rough to receive the topping layer, complete all as specified and as directed by Dy Project Director. |
| 9 | Material and Labour in repair Stone Kerb of roughly squared Sand Stone of size 60 cm long x 45 cm height x 10 cm width, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of the surfaces, jointed in cement mortar 1:6 and struck & flushed, complete all as specified and as directed by Dy Project Director. |
| 10 | Material and Labour granite tile flooring using 20mm thick flamed granite tiles (of any type), machine cut (Straight/radial), bedded and jointed in cement mortar (1:3) with grey cement and pointed with laticrete steller grout to match the shade of granite stone complete and also incluidng all cutting and waste, and fix any size, complete all as specified and as directed by Dy Project Director. (Note:- Screed bed shall be measured and paid for separately. |
| 11 | Material and labour 30 mm polished lakha red Granite in wet and cladding with paper joint and fixed with and incl SS-304 grade clamp, 10 mm dia SS fastner and SS pin (02 no in each stone) and cement plaster 1:3 (CM), complete all as specified and as directed by Dy Project Dir. (Note:- The rates are included all items of the trade). |
| 12 | M&L in reparis, PCC type B-1 (1:2:4) using 20mm graded stone aggregate as in post holes & slightly rounded, ramp of chamfered agnle fast, bed plastes and the like incl use and waste of form work etc levelling course in depressed / undulation portionson etc on floor complete all as specified and directed by Dy Project Director. |
| 13 | Supply, Installation, Testing & Commissioning of LED projector light fixture 15W, LED, IP 66. The housing should be made of high strength pressure die cast aluminium with 3-4mm thick safety glass and coated by static powder making it weather resistant. Protection screen with tempered glass with high impact resistance IK05. Voltage input 24V DC. The luminaire should have options for various beam angle: 25° or 40°. Estimated LED Lifetime is L70-100,000 hours minimum@ 25degree Ambient Temperature . Minimum Light fixture Lumen output atleast 900 Lumens @ full power. Operating Temperature : - 20°C to +50°C. Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Make Orient cat part No DHG FL-1015Note- The rate quoted shall also be deemed to include for material and labour and all other incidental charges required for fixing and mounting arrangements for the fixture including recessing and other civil works as per manufacturer's design and specifications and requirements and also as per site conditions as approved by Dy Project Director. |
| 14 | Supply, installing, testing and commisioning of exterior recessed ground mounted 40mm dia 3W warm white LED linear light fixture IP 67 with DC Power supply, Connectors, Mounting clips and other necessary mounting arrangement with and including LED lamp suitable for the fixture also complyin following specification Voltage-24V DC, Lumen efficacy-48 lumens/Watt,CCT/CRI- 3000K/+80,optical distribution - diffused,complete all as specified and directed by Dy Project Director Make- K Lite model No KL-4086 or equivalent approved make |
| 15 | Supply, installing, testing and commisioning of LED driver 240 Volt input and output Volt 15-30V DC complete all as specified and directed by Dy Project Director.Make- K Lite model No HR035WBML000000 |
| 16 | Supply, Laying and testing of Flame Retardant Low Smoke & Halogen FR-LSH PVC Insulated Industrial Cables Single Core PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cable of size 1.5 Sqmm, 1100 Volt Conforming to IS 694 complete all as specified and directed. |
| 17 | Note: An amount of Rs. Nill on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |