| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in natural ground including taking out embedded portion and making good disturbed ground complete all as directed. |
| 2 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 3 | Excavating in post holes (or similar holes) in soft/loose soil, each n exc 0.5 cu. m, getting out,and removing soil out of the site ,complete all as specified and as directed. |
| 4 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling & mass concrete complete all as specified and directed. |
| 5 | M&L providing plain cement concrete type C-2, (1:3:6), (using 40 mm graded stone aggregate), Cement concrete in foundations, filling and mass concrete complete all as specified and directed. |
| 6 | S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 including preperation of surfaces and applying a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 7 | Supply only chain link MS galvanized fencing 4mm dia and size as ordered, complete all as specified and as directed. |
| 8 | Fixing only chain link fencing including line wire, any mesh, size and any type of standards rails straining bolt etc including provision of binding wire complete all as specified and directed. |
| 9 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed. |
| 10 | M&L MS round bar 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 11 | M&L preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (first quality) over a Red oxide or zinc chrome primer complete all as specified and directed. |
| 12 | M&L preparation new iron and steel surfaces of any description, n. exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of Red Oxide or Zinc Chrome primer complete all as specified and directed. Please Enable Macros to View BoQ information |