| 1 | Contract Details |
| 2 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. |
| 3 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Brick work with non modular brunt clay brick up to floor V level in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | M&L for 20 mm thick in cement plaster of mix 1:4 (1 cement : 4 fine sand) on brick or concrete surfaces finished even and smooth w/o using extra cement complete all as specified and as directed. |
| 6 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) in floor complete all as specified and directed |
| 7 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) complete all as specified and directed |
| 8 | Surface excavation exc (not exc) 30 cm deep in Hard rock/dense soil as specified. |
| 9 | M&L for 100 mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base as specified . |
| 10 | Returning, filling in including spreading levelling and well ramming in layers n exc 25cm each as specified. |
| 11 | Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point as specified . |
| 12 | M&L brick work with fly ash bricks straight or curved on plan exc. 6 mtr mean radius built in CM (1:6) as specified and directed. |
| 13 | M&L PCC 1:3:6 type C-2 (using 40mm graded aggregate) as in flooring surface finished even and smooth without using extra cement all as specified & directed. |
| 14 | M&L for Steel work in tubular trusses/ post including special shaped washer MS plate Hooks Pully ,Socket cap MS bolt etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 as specified. |
| 15 | M&L for preparation of new steel and iron surfaces with any description not otherwise described, over 10cm width or girth and applying two coat of Synthetic enamel over a coat of red oxide zink chrome complete all as specified and directed. |
| 16 | M&L for machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as specified and directed. |
| 17 | M&L for 20mm granite work as on any platform staircase (table rounded and polished) in steps, jambs, pillars, window cills, coocking plateform, Chabutra and like in cement mortar (1:4) inc pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as spd and directed by engg-in-charge |
| 18 | M&L for ACP 3D SIGN Board of Defence institute of bio-energy research with logo of 2.5'*2.5' and trasportation, MS Pipe 1*1 with primer coated 5kg length 18 gauge both side angles 10 inches each ACP sheet 3mm (Indo Bond) with Screw 3mm Acrylic letters with led lights ISO Certified Brand,3mm channel Raising sunboard with power supply 400watt wire 1.5MM as specified and directed. |
| 19 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 20 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 21 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 22 | Precast chequered cement tiles 22 mm thick medium shade using 50% white cement 50% ordinary cement |
| 23 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 24 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 25 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing to be paid for separately) :Note : Wire mesh, rubber bedding, star lock and roller rate included. |
| 26 | Providing and fixing 4 mm thick glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): Please Enable Macros to View BoQ information |