| 1 | Repair / maintenance of street / security lights any type, flood lights, post top lanterns, gate light ,Garden light or any other external lights in its position fixed on pole /building structure or by taking down to ground, if required, testing all the components/parts, wiring etc, identifying and replacing the defective components like electronic driver, connection wires/ cable, MCB etc including refixing the fitting to its original position (if taken down), including repair / maint of street light control timer & junction box complete all as specified and directed .Note: (i) The rate against the above mentioned item is deemed for cost of labour and allied expenses only. (ii) Cost of spares electronic driver, connection wire, MCB, timer contactor spares etc) replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (Continued...) |
| 2 | (continued from item No 1) (iii) The contractor's representative will report to concerned JE E/M at 0900hrs daily to collect the list of defective street light fittings and will submit the completion report on the same day before 21.30hrs to the JE E/M.(iv) The contractor has to rectify the defects / repair and make the street light functional within 24 hours from the time the list of defective street lights is handed over to him / his rep by the concerned JE E/M. In case the street light is not made functional for whatsoever reason within the specified time limit, an amount of Rs 150/- per such defective street light per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall carry out repair / maint work simultaneously for different zones / pocket / areas like :- (a) Offrs residential area D1, D2, D3, E3 including main road from Bombay stadium to peacock bay, road to LVGH & Kondhana.(v) Vehicle mounted hydraulic ladder shall be provided on contractor's request which will be measured separately under Schedule 'C'.(vi) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (viii The contractor shall maintain sufficient stock of spares / material required for repair / maint of street lights with the concerned JE E/M against the supply only items here-in-below. (ix) The details of street / security lights is enclosed as Appx A to Schedule A for general idea about the location and type of light fittings. |
| 3 | Taking down the existing light fittings on multi mounting brackets from 16/21 mtrs highmast pole by taking on ground repairs/ replacing the defective parts like electronic drivers connection wires and refixing the same to its original position complete all as specified and as directed. Note:(i) Cost of spares , electronic drivers,connection wires replaced against above mentioned item above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (ii) The defects / repair of the floodlight making them functional after handing over defective floodlights of highmast(iii) Maintaining proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every flood light and getting it authenticated. (iv) Safety of his men engaged for executing the work along with safety equipment and clothes for the men shall be maintained. |
| 4 | Supply only following street light spares of branded make as mentioned in the list of make enclosed with Particular specifications for replacement :- Electronic driver suitable for 90watts LED security light fittings Make should be as per the Existing manufacturer complete all as specified and as directed. |
| 5 | Supply only Electronic driver for 30/40/ 45 / 48 / 50/60 watts LED road way/Flood light/post top Make should be as per the Existing manufacturer complete all as specified and as directed. |
| 6 | Supply only Electronic driver for 400/300 watts flood lights Make should be as per the Existing manufacturer complete all as specified and as directed. |
| 7 | Supply only Electronic driver for 200 watts flood lights Make should be as per the Existing manufacturer complete all as specified and as directed. |
| 8 | Supply only Electronic driver for 150 watts flood lights Make should be as per the Existing manufacturer complete all as specified and as directed. |
| 9 | Supply only Electronic driver for 50/100 watts flood lights Make should be as per the Existing manufacturer complete all as specified and as directed. |
| 10 | Supply only MCB SP 230 volts B curve 6 amps complete all as specified and as directed. |
| 11 | Supply only MCB DP 230 volts C curve 6 amps complete all as specified and as directed. |
| 12 | Supply only MCB TPN 415 volts C curve 63 amps complete all as specified and as directed. |
| 13 | Supply only MCB TPN 415 volts C curve 40 amps complete all as specified and as directed. |
| 14 | Supply only Digital Time Switch (16A): DIN-rail mounted weekly timer, 25 ON/OFF programs, with battery backup for 16A/250V AC lighting circuits complete all as specified and as directed. |
| 15 | Supply only Magnetic Contactor: 40A AC-3, 3-Pole, 230V Coil for automated lighting control complete all as specified and as directed. |
| 16 | Supply only PVC insulated Copper conductor FRLS grade three core cable 2.5 sqmm, ISI marked complete all as specified and as directed. |
| 17 | Supply only PVC insulated aluminium conductor two core round cable 4 sqmm, ISI marked complete all as specified and as directed. |
| 18 | Supply only PVC insulated aluminium conductor two core round cable 6 sqmm, ISI marked complete all as specified and as directed. |
| 19 | Supply only 63A 4-Pole MCCB (16kA) of 63A 415V 4P MCCB with Thermal-Magnetic trip unit, 16kA breaking capacity, including spreaders and terminations complete all as specified and as directed. |
| 20 | Material & Labour for a straight-through joint (Epoxy Resin type) for 1.1kV grade, 4-core PVC insulated and sheathed Aluminium conductor underground cable, with conductor sizes ranging from 10 sq. mm to 25 sq. mm. High-quality Epoxy/Polyurethane cold-pour resin kit, providing high dielectric strength and excellent mechanical protection including all necessary accessories such as Ferrules/Thimbles (Aluminium), spacers, abrasive strips, resin and hardener, and a transparent/high-impact plastic mold.Also includes anti-corrosive nuts, bolts, washers, and continuity bonding for the cable armour complete all as specified and as directed. |
| 21 | Labour Only for Laying, testing, and commissioning of 1.1kV grade, 25 sq. mm x 4-core Aluminum conductor, XLPE insulated, armored heavy-duty cable. (Note: Cable shall be issued by the Department Sch B) Loading from the store, transportation to the work spot, trenches (on sand cushioning), Laying of cable in trenches , through hume pipes/ducts, or along walls/poles using heavy-duty GI spacers and clamps as per site requirements.Supply and fixing of all necessary installation materials including heavy-duty Aluminum lugs (25 sq. mm), brass compression glands, identification tags, and cable ties.The rate includes all labour, tools, tackles, testing equipment, and consumables required for a complete installation, complete all as specified and as directed. |
| 22 | All as per item No 20 above but size 16 sqmm 4 core (Note: Cable shall be issued by the Department Sch B) |
| 23 | All as per item No 20 above but size 10sqmm 4 core (Note: Cable shall be issued by the Department Sch B) |
| 24 | All as per item No 20 above but size 6 sqmm 4 core (Note: Cable shall be issued by the Department Sch B) |
| 25 | All as per item No 20 above but size 4 sqmm 3 core (Note: Cable shall be issued by the Department Sch B) |
| 26 | Excavation in trenches in any type of soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out including dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and as directed. |
| 27 | Returning, filling in including spreading, levelling watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested as specified |
| 28 | Removing excavated surplus soil obtained from excavation to a distance not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point, complete all as specified and as directed. |
| 29 | Supply and laying 40 mm outer dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e coupler, Tee, elbow clamp for cable protection complete all as specified and as directed. |
| 30 | Supply and fix in replacement of junction box thermo plast (weather proof) IP 66, on street light poles made out of thermoplastic of size 300mm x 200 mm x 105 mm size with connector for connecting incoming and outgoing of cable including 01 No of MCB DP 06 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incoming, outgoing of cable complete all as specified and as directed. |
| 31 | Supply and fix in replacement of junction box thermo plast (weather proof) IP 66, on flood light poles made out of thermoplastic of size 140mm x 140 mm x 95 mm size with connector for connecting incoming and outgoing of cable including 01 No of MCB SP 6 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incoming, outgoing of cable complete all as specified and as directed. |
| 32 | Supply and fix in replacement of Plexo Box IP 65 (weather proof), on Gate/Post top Latern/Bollard As per IEC 61439-3 suitable for Flush Mounting and Surface Mounting With 100 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCB's as outgoing for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incoming, outgoing of cable complete all as specified and as directed. |
| 33 | S&F in replacement MCB DB 02 way SPN (single door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including MCB SPN 06 Amp 230V, 50 HZ, complete all as specified and as directed. |
| 34 | S&F in repair of GI pipe bracket of 40 mm dia 1.2mtr long bend to shape for street light fitting made out of 40 mm dia GI light grade pipe fixed on pole using new FI clamp including necessary new nut, bolt and washer complete all as specified and as directed. |
| 35 | Supply & fix GI tubing light grade 40 mm dia ISI marked appx 1 mtr to 1.5 mtr long with Flat Iron Base for mounting of Flood light with all fittings including nut,bolt,washers suitable size complete all as specified and as directed. |
| 36 | S& F GI tubing light grade 50 mm dia ISI marked for bollard light with all fittings laid in trenches and fixed pole by flat iron clamps, nut ,bolt,washers suitable size complete all as specified and as directed. |
| 37 | Labour for trimming and pruning of tree branches, foliage, and creepers overhanging, interfering with, or obstructing electrical poles, street light fixtures, or overhead conductor lines.Pruning shall be executed to ensure a minimum radial clearance of 1.5 meters around the street light pole, bracket, and luminaire fitting in all directions.The trimming must be done using appropriate insulated tools (tree pruners, long-reach saws) to ensure the safety of the workers and prevent any mechanical impact on the light fitting or electrical cables.The scope includes the collection, removal, and neat stacking of all cut branches and debris at a designated spot within the premises or disposal outside the site as directed including all safety measures like PPE (harnesses, helmets, insulated gloves) complete all as specified and as directed. |
| 38 | Material and labour for Tarmac bituminised road cutting by using suitable hydraulic road cutter for a width not exceeding 300 mm and depth 600 mm for laying of 80 MM medium grade GI pipe including refilling and making good with Tarmac/ PCC duly matching with the existing surface complete all as specified and as directed. |
| 39 | Supply & fixing in replacement of 30 watt LED flood light luminaire Warm white/white in colour with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 complete all as specified and as directed. |
| 40 | Supply & fixing in replacement of 50 watt LED flood light luminaire warm white/white in colour with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 complete all as specified and as directed. |
| 41 | S & F in replacement of 100 watts flood light warm white/white in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS channel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole complete all as specified and as directed. |
| 42 | S & F in replacement of 150 watts flood light Warm white /White in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS channel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole complete all as specified and as directed. |
| 43 | S & F in replacement of 200 watts flood light Warm white in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,single phase, etc fixing in MS channel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole complete all as specified and as directed. |
| 44 | Supply & fixing in replacement of 300 watt LED flood light luminaire with separate driver assemble box with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66, with suitable mounting structure complete all as specified and as directed. |
| 45 | Supply and fix in replacement integral LED aviation light comprising housing with polycarbonate enclosure, aviation light is to be fixed on highmast light frame complete all as specified and as directed. |
| 46 | Labour only for fixing, testing, and commissioning of a 30W to 100W LED Street Light fixture any make on an existing pole bracket or wall-mounted GI pipe.The rate includes all labour, ladder, tools, safety harnesses, and mounting hardware (nuts/bolts/washers) complete all as specified and as directed. Note: (1)The LED light fixture shall be issued by the Department from the store under Schedule B. (2)All old unserviceable fittings removed during the replacement old fittings to the MES Store. Proper credit/receipt must be obtained from the Store-in-Charge and submitted to the Engineer-in-Charge for final billing. |
| 47 | Supply and Fixing in replacement outdoor Spike light 20 W LED with Base with polycarbonate diffuser and IP 65 protection including demolition of existing PCC and make suitable PCC for new gate light and fixing arrangements complete all as specified and as directed. |
| 48 | Supply and Fix in replacement integral 18/20Watt LED post top lantern black/ copper dust painted cast aluminium spigot, spun aluminium canopy with clear acrylic cover and accessories on on existing GI Pipe of diameter complete all as specified and as directed. |
| 49 | Supply & fix in replacement 40 watt LED post top made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 65 protection complete all as specified and as directed. |
| 50 | Supply and Fixing 1x15/18 watt WW (3000K)with E 27 Holder and bulb, bollard integral decorative LED bollard with polycarbonate diffuser and IP 65 protection including demolition of existing PCC and make suitable PCC for new bollard and complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 51 | Supply and Fixing 1x15/18 watt WW (3000K)with E 27 Holder and bulb, bollard integral decorative LED bollard with polycarbonate diffuser and IP 65 protection including demolition of existing PCC and make suitable PCC for new bollard and complete all as specified and as directed. Please Enable Macros to View BoQ information |