| 1 | Demolition Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 2 | Demolition cement concrete is reinforced Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 3 | Demolition of brick work / stone masonry / block masonry built in built in cement mortar or cement lime mortar complete all as specified and as directed. |
| 4 | Dismantling plain or corrugated steel/asbestos sheeting , any gauge or any thickness, as in roof coverings complete all as specified and as directed. |
| 5 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from any type of soil/ position and making good disturbed ground complete all as specified and as directed. |
| 6 | Dismantiling chain link fencing wire mesh of any type complete all as specified and as directed. |
| 7 | Dismantiling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 8 | Taking Down Old RCC Louvered Jalli/ Jaffery without harming the exisiting wall of Stone/ Block or Bricks masonry complete all as specified and directed. |
| 9 | Taking down cement plaster on brick/ stone walling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 10 | Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth for foundation, cable etc. or for shafts, wells, cesspits, manholes, pier holes, pole etc. n. exc 10 sq m on plan and getting out in hard/ dense soil complete all as specified and as directed. |
| 11 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate.) as in foundation filling & mass concrete, bed of manholes etc. complete all as specified and directed. |
| 12 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick with soils complete all as specified and as directed. |
| 13 | Removing of excavated material (soil) to distance exceeding 1.5Km and not exc. 5Km and deposited where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed. |
| 14 | Material and labour in repair for 200mm bore RCC pipes, class NP-3 laid and jointed with collars and tested including demolition and breaking up 200mm bore dia drain pipes (salt glazed earthern ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed. |
| 15 | Material and labour in repair for 300mm bore RCC pipes, class NP-3 laid and jointed with collars and tested including demolition and breaking up 300mm bore dia drain pipes (salt glazed earthern ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed. |
| 16 | Material and labour for PCC (1:3:6) type C2 ( using 40mm graded broken stone aggregates) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore of pipe including demolition of existing PCC complete all as specified and as directed. |
| 17 | Material and labour for PCC (1:3:6) type C2 ( using 40mm graded broken stone aggregates) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 300mm bore of pipe including demolition of existing PCC complete all as specified and as directed. |
| 18 | Material and labour for rendering 15mm thick in cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 19 | M&L Precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slab for man hole/ drains etc and set in CM1:6 complete all as specified and as directed. |
| 20 | S & F of rolled mild steel in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc,; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde e-165, complete all as specified and directed |
| 21 | M&L for mild steel framed work such as grill, grating, gate etc with ends of bars shouldered or rebated or forged into spike framed guard bars barred iron doors, ladders, framed baluster, walk way, railing; frame work, including pintle hinges, stops, hand-made sliding bolts etc,sliding channels for sliding of gate and similar work conforming to Fe 290 Gde-E-165 complete all as specified & as directed. |
| 22 | S & F Framed work in side hung gates( including pintel hinges, stops, hand made sliding bolts)/ grills with ornamental and intricate design, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe. 290.Gde-E-165 |
| 23 | S&F mild steel rolled section as in main cross beams purlins, rafters and running rails fixed independently with angle iron cleats or connecting pieces conforming to Gde Fe-410-W, Gde E-250, quality A complete all as specified and as directed. |
| 24 | M&L for preparation and applying one coat of synthetic enamel paint on old steel surfaces of any description exc 10 cm in witdth or girth complete all as specified and as directed. |
| 25 | M&L two coats of synthetic enamel paint on new steel surfaces over a coat of red oxide primer surfaces of any description exc 10 cm in witdth or girth complete all as specified and as directed. |
| 26 | M&L Granite (of any type) work (table rubbed and polished) of 20mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 27 | M & L stone walling of Random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed. |
| 28 | All as per Srl item No. 27 above but except stones |
| 29 | Material and labour for Flush pointing to block in course or ashlar masonry or concrete block walling in cement mortar 1:3 including raking out joints complete all as specified and as directed |
| 30 | M&L Brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 etc including demolition of brickwork built in cement mortar complete all as specified and directed. |
| 31 | M&L for Pre-cast cement concrete block masonry with solid blocks type C1, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and as directed. |
| 32 | M&L for preparation of newly plastered surfaces and applying two coats of weather proof exterior emulsion paint ('APEX' brand of Asian or equivalent brand of Berger/Shalimar) over one coat of primer to wall complete all as specified and as directed by Engineer-in-charge. |
| 33 | M & L for cement concrete Type B0 1:2:4 (20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles andthroating, complete all as specified and as directed. |
| 34 | M & L for Formwork to sides and soffits of floor or roof beams, coping, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed |
| 35 | M&L for RCC (Nominal mix)1:2:4, type B1 as in columns, pillars, piers,posts and struts complete all as specified and as directed. |
| 36 | S & F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 37 | -Ditto- all as per tem No 36 above but 6-8mm dia stirrups |
| 38 | M & L for Formwork to sides of columns/beams (squar/rectangular) complete all as specified and as directed. |
| 39 | M & L precast cement concrete Type B0 1:2:4 (12.5mm graded aggregate) louvres and jallies, 40 mm thick (measured solid), in cluding all mould- ings complete all as specified and directed |
| 40 | Excavating in post holes in hard/dence each n exc 0.5 cum, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed. |
| 41 | M&L for providing 10 mm thick hollow polycarbonate sheet of any colour or any discription including neccesary bolting and riveting complete all as specified and directed |
| 42 | M & L 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. complete all as specified and directed |
| 43 | S&F in repair for 6mm thick asbestos cement, two piece adjustable serrated ridge for corrugated or semi corrugated sheets fixed with L-type or J-type or cranked hook bolts etc. complete all as specified and as directed. |
| 44 | S & F Plain, galvanised, mild steel sheeting,0.63mm in ridges, hips, valley gutters, drip and straight flashings (length and girth asfixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 45 | S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 46 | M & L for Machine pressed precast concrete interlocking paver block with gray cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and as directed |
| 47 | Fixing only interlocking tile of any thickness and size including 30mm thick sand cushoning complete all as spcified and as directed. |
| 48 | M&L textured heavy duty parking tile of size 300mm X 300mmX10mm thick , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including a screed bed in CM 1:4 complete all as specified and as directed. Make :- Jonhson endura textured design or equivalent of kajaria/ somany. |
| 49 | M&L for 25mm thick coloured glossy rubber moulded chequered cement concrete tiles with grey cement & pigment of area exc. 0.08 Sqm and n.exc 0.16sqm each, set, jointed and pointed in net cement slurry mixed with grey cement and pigment in floors including 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes including dismantling of existing complete all as specified and as directed. |
| 50 | M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 51 | M & L 75 mm thick cement concrete (1:4:8) type D2 (using 40mm grade broken stone aggregate) as in sub base complete all as specified and as directed. |
| 52 | M&L for Filleting in any position and to any shape in cement mortar 1:4 exc.25 but n exc.50 sq.cm including all mitres, stops, etc. complete all as specified and as directed. |
| 53 | M&L for preparation of old plastered surfaces and applying two coats of weather proof exterior emulsion paint ('APEX' brand of Asian or equivalent brand of Berger/Shalimar) over a coat of primer on wall using Electrically opreated spray machine including complete removal of existing treatment using electrically oprated dry wall sanding machine complete all as specified and as directed by Engineer-in-charge. NOTE: This item of work is to be operated upto 15m Building Height |
| 54 | M&L for preparation of old decorated surfaces and applying one coat of weather proof exterior emulsion paint ('APEX' brand of Asian or equivalent brand of Berger/Shalimar) on wall complete all as specified and as directed by Engineer in-charge. NOTE: This item of work is to be operated upto 15m Building Height |
| 55 | Removing of vegetation / plantation on the wall/ roof/ any position of up to double storey building including necessary scaffolding and roots, girth n. exc. 10cm each and applying chemical treatment with GLYPHOSATE 41% and making good of surface incl removing /refixing of CI/GI pipe lines complete all as specified and as directed. (Note : Brick work, plaster and CI/GI pipe lines shall be measured and paid separately) |
| 56 | M&L in repair for concentina punch type wire 610 mm dia of each coil avg weight n less than 1.06 kg/RM after stretching including coating of anti rust compound fixed on angle iron bracktes top of compound wall complete all as speified and as directed. |
| 57 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as speified and directed. |
| 58 | Supply Chain link MS galvanisd fencing, any size or type complete all as specified and as directed. |
| 59 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed. |
| 60 | S&F MS Screw bolts ( machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut but length of bolt exc 25mm but n exc 50mm long, dia of 5 to 10 mm dia of neck all as specified. |
| 61 | M&L for round bars 10mm dia and over cut to length& fixed as in straining bars for stiffining chainlink fence complete all as specified and as directed. |
| 62 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 63 | M&L for cleaning existing concrete/tile/interloking blocks pavement to include removal of moss, algae and other organic matter using manual/machenical scrapping, pressure washing bleaching and making good by aligning tiles and making up filler sand in joints to achiev clean, smooth and levelled surfaces complete all as specified and as directed. |
| 64 | M&L for painting of old concrete/tile/interlocking pavement by applying two coats of acrylic based paving paint of desired colour and finish complete all as specified and as directed. |
| 65 | M & L for preparation of new/old concrete surfaces/kerb stone of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. |
| 66 | Material and labour 75mm thick PCC (1:3:6) type C2 (using 40mm graded broken stone aggregate) as in plinth protection/court yard finishing the surface even and smooth without using extra cement including demolition of existing complete all as specified and as directed. |
| 67 | Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. Please Enable Macros to View BoQ information |