| 1 | Demolition of brick work or stone/boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 2 | M&L Brickwork with sub class 'B' bricks bricks (using old size bricks), straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 3 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise spcifically provided for complete all as specified and directed. |
| 4 | M & L for cement concrete type D2, 1:4:8 ( using 20mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 5 | M & L for cement concrete type B2, 1:2:4 ( using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed. |
| 6 | Taking down cement plaster on brick wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 7 | M & L for rendering 15 mm thick on fair faces of brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | Cleaning out manhole covers/gully traps of any type and any depth removing the sludge/solid content from the manhole/gully trap by manual/ mechanical method and also cleaning the sewage line of any dia and at any depth either by water pressure or by any other flushing or roding and other suitable means at the discretion of the contractor at his own arrangements so as to remove the blockage and making the sewer lines and manhole/gully trap fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab all as directed by the Engineer-in-Charge. |
| 9 | Desilting of septic tank/soakage pit of any size, type.capacity and any depth by adopting necessary safety measures / equipments and removing the sludge/solid content from the septic tank/soakage pit by manual/ mechanical method or any other suitable means at the discretion of the contractor at his own arrangements and make the septic tank/soakage pit fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab all as directed by the Engineer-in-Charge. |
| 10 | Cleaning of blockage IWC, EWC, Wash Basin, gully trap, floor trap etc either by hand pump or by rodding or by any other means untill clear flow is observed all as specified and as directed by Engr -in Charge |
| 11 | M&L in repair for Framed work such as in grills, gratings with ends of bar shouldered and/ or riveted forged into spikes including welding complete all as specified and directed. |
| 12 | M&L for Preparation of new or previously untreated steel surface over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 13 | Removing & refixing of RCC drain cover of any size using mechanical arrangements such of fork lifter etccomplete all as specified and directed. |
| 14 | Demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 15 | M&L for Precast RCC 1 : 2 : 4 type B-1 (using 20mm graded stone aggregate) for cover slab of any size including necessary form work and set in cement mortar 1:6, complete all as specified and directed. |
| 16 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | M & L for cement concrete type B-0, 1 : 2: 4 mix using 12.5mm graded stone aggregate as in coping including necessary form work all as specified |
| 18 | M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection, path/hardstanding/subbase etc complete all as specified and directed by EIC. |
| 19 | M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment laid and bedded on sand cushioning complete all as specified and directed. |
| 20 | M&L for sand filling under floors/ paver block or in foundations including watering and consolidation |
| 21 | Providing and laying at or near ground level factory made kerb stone of M-25 gradeof any size cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required including dismantling/demolition of existing complete all as specified and directed |
| 22 | M&L for preparation of new concrete surfaces and applying two coats of exterior emulsion paint with one coat of primer in normal pattern as per manufacturers instructions etc complete all as specified and directed by Engr-in-charge. |
| 23 | Dismantling floor, hearth or wall tiling including cement mortar bedding and removing rubbish off the premises complete all as specified and as directed |
| 24 | M&L 20-25mm thick coloured chequered tiles, area of each tile exe 0.05 sqm but n.exe 0.09sqm with and incl 15mm thick screed bed in CM (1:6) of approved colour and pointing with grey cement and pigment complete all as specified and directed. |
| 25 | M&L for PCC 1:3:6 type B-1 ( 20mm graded stone agg) in floor etc and finished the concrete surface even and fair complete all as specified and directed. |
| 26 | M&L hardcore of guage n.exc 63 mm, deposited spread and levelled in layres n.exc 15 cm thick watered and rammed to true surface using broken stone/boulders etc complete all as specified and directed. |
| 27 | Taking down carefully aluminium/copper point wiring (light/fan/socket or power) complete including fitting fixtures such as switches, socket, ceiling rose, brackets, holders, bulk head/tube light fitting etc. and making good disturbed surface of walls/ floors etc. complete all as specified and directed |
| 28 | M&L for point wiring for hanger light complete with FRLS PVC insu;ated, PVC unsheated electric cable conforming to IS 694 1100 volts grade AC single core having stranded FRLS copper conductor of size 1.5 Sqmm nominal cross sectional area for phase and neutral drawn in and including1.6mm thick concealed ERW stove enameled rigid steel conduit ISI marked not less than 20mm dia with including 1.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed: - Note- The contractor shall considered following aspect before quoting his rates. No extra claim shall be entertained. (i) The working height for hangar lights is appx 21 m above ground level. (ii) Cost of scafolding and other T&P .(iii) The maximum length to be considered in each point is 30.00 m. |
| 29 | One hanger light controlled by one MCB SP. |
| 30 | Two hanger light controlled by one MCB SP. |
| 31 | M&L Point wiring for One light/fan point controlled by one switch using approved colour coding as per IS, with Zero Halogen Flame retardant (HFFR), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 1.5 Sq. mm (nominal area), single core, insulated and unsheathed stranded cable 1100 Volts grade ISI-694 marked TEC and FIA approved in & including heavy duty, electric resistance welded (ERW) stove enameled rigid steel surface mounted conduit of size not less than 20mm dia, heavy duty ISI marked as per IS:9557 (Part I) 1980 for one light points controlled by one Switch , including HFFR insulated unsheathed unitary construction copper conductor 1.5 Sq. mm nominal cross sectional area wire as earth continuity conductor up to common earth and connecting to earth dolly. All conduit accessories such as bends elbows Tee etc shall be Flame proof certified by CMRS Dhanbad complete all as specified and directed :- |
| 32 | M&L Point wiring for socket point using approved colour coding as per IS, with Zero Halogen Flame retardant (HFFR), smoke free, non toxic, non corrosive installation cable with UNILAY construction copper conductor 2.5 Sq. mm (nominal area), single core, insulated and unsheathed stranded cable 1100 Volts grade ISI-694 marked TEC and FIA approved in & including heavy duty, electric resistance welded (ERW) stove enameled rigid steel surface mounted conduit of size not less than 20mm dia, heavy duty ISI marked as per IS:9557 (Part I) 1980 for one light points controlled by one Switch , including HFFR insulated unsheathed unitary construction copper conductor 2.5 Sq. mm nominal cross sectional area wire as earth continuity conductor up to common earth and connecting to earth dolly. All conduit accessories such as bends elbows Tee etc shall be Flame proof certified by CMRS Dhanbad etc copmplete all as specified and directed. |
| 33 | S&F in repair flame proof switch socket & plug combined controlled by single pole one way 16 Amp ON-OFF rotary switch. Flame proof switch socket & plug combined in LM6 cable termination box , 250V, 2P+earth complete all as specified and directed. |
| 34 | S&F in repair flame proof weather proof rotary switch with cable terminal box in cat aluminum alloy ( LM-6) construction, epoxy powder coated, single pole 16 Amp ON/OFF type, 230 V AC, certified by CMRS for Group IIA & IIB including compression glands etc complete all as specified and directed. |
| 35 | S&F in repair LED flameproof tube light fitting batten type CMRI certified suitable for single T8 tube of 16W/20W. Recommended for Gas/Vapour group of IIA & llB and Zone 1 & 2 .IP65 Protected LED flameproof made of aluminium alloy LM6 etc. complete with all accessories, prewired and including connecting up with suitable size of twin core twisted flexible copper conductor cable complete all as specified and directed. |
| 36 | S&F in repair flemproof and weatherproof distibution panel SPN 4 way AC, 240 volts . Incoming- MCB 2P ,25 A - 1 No and outgoing -MCB 10 A -2 No (MCB- L& T / Schneider /Legrand make) with complete internal bus bar & wiring up to terminals and match the existing disturbed surfaces complete all as specified and directed . |
| 37 | S&F in repair flemproof and weatherproof distibution panel SPN 6 way ( Encloser size : 300x300x190mm ) AC, 240 volts . Incoming- MCB 2P ,40 A - 1 No and outgoing -MCB 6/10 A -4 No (MCB- L& T / Schneider /Legrand make) with complete internal bus bar & wiring up to terminals and match the existing disturbed surfaces complete all as specified and directed . |
| 38 | S&F in repair MCB, SP, AC, 240 volts of 06 to 32 Amps capacity \\"C\\" series and making connections complete all as specified and directed. |
| 39 | S&F in repair MCB, SP, AC, 240 volts of 32 to 63 Amps capacity \\"C\\" series and making connections complete all as specified and directed. |
| 40 | S&F in repair isolator, SPN, AC, 240 volts of 6-32 Amps for inductive load connected through cable lugs of suitable size, complete all as specified and directed. |
| 41 | S&F in repair isolator, SPN, AC, 240 volts of 40-63 Amps for inductive load connected through cable lugs of suitable size, complete all as specified and directed. |
| 42 | M&L for flame proof and weather proof threaded type junction box JB/153 Upto 1\\" ET / M25 4 Way suitable for Flame Proof Exaust Fan of size 380mm (15\\") complete all as specified and directed |
| 43 | S & F in Repair sub main wiring with approved colour coding as per IS (Red, Black and green for single phase circuits) with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable (Red&Black colour) of size 6.0 sqmm drawn in and including steel rigid conduit not less than 32mm dia with its accessories, surface type, including one run of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable (Green colour) of size 6.0 sqmm as earth continuity and connected to common earth dolly complete all as specified & directed.Note:- Two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith steel conduit including its accessories shall be measured and paid as one unit. |
| 44 | S & F in Repair sub main wiring with approved colour coding as per IS (Red, Black and green for single phase circuits) with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable (Red&Black colour) of size 4.0 sqmm drawn in and including steel rigid conduit not less than 32mm dia with its accessories, surface type, including one run of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable (Green colour) of size 4.0 sqmm as earth continuity and connected of common earth dolly complete all as specified & directed.Note:- Two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith steel conduit including its accessories shall be measured and paid as one unit . |
| 45 | S&F in repair flame proof weather proof rotary switch 16 Amp with cable termination box in LM6 MCB single pole 6 to 16 Amp 10 KA , 220 volt 50 Htz , Single pole ON-OFF as per existing complete all as specified and directed. |
| 46 | Supply and fix in repair Flame proof and weatherproof exhaust fan 375mm (15 inch) 0.25HP ac single phase 230 V with louvers |
| 47 | Supply and fix in repair Flame proof knob ac single phase 230 V |
| 48 | S&F in repair flame proof weather proof rotary switch 25 Amp with cable termination box in LM6 MCB double pole 10 KA 220 volt 50 Htz , Double pole ON-OFFas per existing complete all as specified and directed. |
| 49 | S&F in repair flame proof flexible mild steel plug of size 300 mm long complete all as specified and directed. |
| 50 | S&F in repair 40 W , LED light fitting energy saving CIMFR certified flame proof wellglass in die cast aluminium housing with heat resistant toughened glass recommended for Gas/Vapour group of llA & llB and Zone 1&2 .IP65 complete all as specified and directed. |
| 51 | S&F in repair 60 W , LED light fitting energy saving CIMFR certified flame proof wellglass in die cast aluminium housing with heat resistant toughened glass recommended for Gas/Vapour group of llA & llB and Zone 1&2 .IP65 complete all as specified and directed. |
| 52 | M&L for disconnection and taking down any type and any watt tube light fitting from wall/ceiling for cleaning & repair including replacement of worn out parts to make it fully functional and re-fixing on existing location complete all as specified and as directed. Note : Worn out parts which are to be replaced will be measured and paid separately as supply only under respective items of BOQ . |
| 53 | S&F in repair 20 W , Photon ultra plus LED tube light rod with new Ultra bright LED polycarbonate tubelight with <10% THD with very high efficacy suited for installation in existing old serviceable T8 tube light batten type fitting with G13 lamp holders and making electric connection complete all as specified and directed. |
| 54 | S&F in repair ultra bright LED PL-I light fitting with very high efficiency 18 watt LED 4pin suited for installation in existing 2G11 lamp holders. complete all as specified and directed. |
| 55 | S&F in repair 120 watt , LED, Flame proof flood light fitting with lens energy saving,environment friendly , long life ,exclusive innovative die-cast aluminium housing complete all as specified and directed. |
| 56 | S&F in repair 150 watt , LED, Flame proof flood light fitting with lens complete energy saving,environment friendly , long life ,exclusive innovative die-cast aluminium housing complete all as specified and directed. |
| 57 | M&L for rewinding of burnt flame proof Wall mounting fan/ exaust fan/Pedestal fan (after opening and taking out burnt winding) with suitable size of super enameled copper winding wire as per existing/ original specification of exaust fan including proper insulation with varnish etc and testing on full load complete all as specified and directed for the following sizes:- |
| 58 | 600 mm sweep, 230 Volt, AC 900 RPM. |
| 59 | 300 to 400mm sweep, 230 Volt, AC 900 RPM. |
| 60 | 457(18\\") mm sweep, 230 Volt, AC 1440 RPM. |
| 61 | Taking down of Wall mounted fan/Exhaust fan/Pedestal fan/ Air circulator of any size/ sweep/make from any height of building & dismantling/ opening of blade, stator rotor of ceiling fan for cleaning and servicing/ over hauling by providing oil /grease to the bearings/ bushes and replacement of defective/wornout parts/ spares i.e condenser, bearing, bush, canopy, rubber reel, MS clamp with nut, bolt & washers and locking split pin and reassembling, commissioning testing of ceiling fan including hanging the same on existing location/ place complete all as specified and directed. Note:- Replacement/Renewal of defective/ wornout parts/ spares of fan i.e condenser, bearing, bush, canopy rubber reel, MS clamp and nut, bolt, washers & locking split pin shall be measured and paid separately under respective items of BOQ as supply only. |
| 62 | Supply only of bush suitable for exaust fans, wall mounted and pedestal fans of flame proof any size & type complete all as specified and directed. |
| 63 | Supply only ball bearing suitable for exaust fans, air circulating fan, wall mounted and pedestal fans of Nos. 6201/6202 complete all as specified and directed. |
| 64 | Supply only ball bearing suitable for exaust fans, air circulating fan, wall mounted and pedestal fans of Nos. 6203/6204 complete all as specified and directed. |
| 65 | Supply only MS nuts & bolts of suitable sizes with split pin suitable for exaust fan / air circulating fan / wall mounted fan etc complete all as specified and directed. |
| 66 | Supply only condenser 2.5/ 4.0 mfd suitable for ceiling fans / exaust fans / wall mounted and pedustrial fans of any type & size complete all as specified and directed. |
| 67 | Supply only of aluminium blades suitable size for pedestal/ air circulator fan of 450/ 600mm sweep as per sample complete all as specified and directed. |
| 68 | S&F in repair louvers , suitable for flame proof exhaust fan of size 457 mm (18\\") complete all as specified and directed |
| 69 | S&F in repair blade , suitable for flame proof exhaust fan of size 457 mm (18\\") , complete all as specified and directed |
| 70 | S&F in repair bird catcher suitable for flameproof exhaust fan of size 457 mm (18\\") complete all as specified and directed |
| 71 | S&F in repair aluminium blade for flame proof padstal fan of size 457mm (18\\") complete all as specified and directed |
| 72 | S&F in repair Wire guard for padstal fan of size 457mm (18\\") complete all as specified and directed |
| 73 | M&L for disconnection and taking down any type of flame proof heating blower for parashuit ,230 V ,250W-500W single phase with heating strip any type , watt, including cleaning, repair, overhauling and replacement of worn out parts to make it fully functional and re-fixing on existing location complete all as specified and as directed. Note :The Worn out parts which are to be replaced will be measured and paid separately as supply only under respective items of BOQ . |
| 74 | M&L for rewinding of burnt flame proof Heating blower moter of capcity 1/2HP,1440RPM (after opening and taking out burnt winding) with suitable size of super enameled winding wire as per existing/ original specification of heating blower moter including proper insulation & varnishing etc. and testing on full load complete all as specified and directed. |
| 75 | M&L for rewinding of burnt flame proof Heating blower moter of capcity 1 HP,1440RPM (after opening and taking out burnt winding) with suitable size of super enameled winding wire as per existing/ original specification of heating blower moter including proper insulation & varnishing etc. and testing on full load complete all as specified and directed. |
| 76 | S&F in repair flame proof heating strip 750watt 230v,single phase as per existing size& model suitable for heating blower complete all as specified & directed. |
| 77 | S&F in repair flame proof heeting strip 1.5kw 230v,single phase as per existing size& model suitable for heating blower complete all as specified & directed. |
| 78 | S&F in repair of adjustable type thermostat of range 30 degree Celcius to 85 degree Celcius, ISI marked as approved by GE suitable for heating blower complete all as specified & directed. |
| 79 | S&F in repair contactor (for any type flame proof heating blower for parashuit) 3 phase 20 Amp 415 V, complete all as specified & directed. Please Enable Macros to View BoQ information 1. All worn out/unserviceable materials/items which will be obtained from different items of Sch `A’/ BOQ (as mentioned above) during replacement work, shall become contractor’s property and amount of credit shall be recovered from the contractor's RAR & final bill as and when payments are submitted. These materials shall be allowed to be removed from works site only after credit amount for the same is recovered from the contractor’s payment. Items not covered under this Schedule shall become the property of department and the same shall be returned/ deposited by the contractor at MES store yard without any extra cost to department/ government and all materials which are credited to the contractor, shall be recorded in MB 2. The contractor shall have no claim regarding fixation of credit rates in this schedule and no rebate on \\"Schedule of credit\\" rates/ amount shall be accepted. However contractor can offer more credit rates/ amount. 3. The total credit amount may vary as per execution of work above different items involved in this credit schedule. 4. The quantities given in column 4 are provisional and same shall be measured and paid based on actual quantities obtained against relevant items of Schedule ‘A’/ BOQ. These materials shall not be reused/ reincorporated in the work except where specified. 5. The measurements of dismantled materials shall be the gross quantity obtained and not the net quantity considered for payment in schedule. The old and unserviceable materials to be retrieved from taking down/demolition/dismantling etc are considered in schedule of credit. No claim of contractor with regard to quality/position of old materials shall be entertained Srl No Description of item Qty Unit Assessed rate by department Remarks Rate in (Rs) Amount in (Rs) |
| 80 | S&F in repair contactor (for any type flame proof heating blower for parashuit) 3 phase 20 Amp 415 V, complete all as specified & directed. Please Enable Macros to View BoQ information 1. All worn out/unserviceable materials/items which will be obtained from different items of Sch `A’/ BOQ (as mentioned above) during replacement work, shall become contractor’s property and amount of credit shall be recovered from the contractor's RAR & final bill as and when payments are submitted. These materials shall be allowed to be removed from works site only after credit amount for the same is recovered from the contractor’s payment. Items not covered under this Schedule shall become the property of department and the same shall be returned/ deposited by the contractor at MES store yard without any extra cost to department/ government and all materials which are credited to the contractor, shall be recorded in MB 2. The contractor shall have no claim regarding fixation of credit rates in this schedule and no rebate on \\"Schedule of credit\\" rates/ amount shall be accepted. However contractor can offer more credit rates/ amount. 3. The total credit amount may vary as per execution of work above different items involved in this credit schedule. 4. The quantities given in column 4 are provisional and same shall be measured and paid based on actual quantities obtained against relevant items of Schedule ‘A’/ BOQ. These materials shall not be reused/ reincorporated in the work except where specified. 5. The measurements of dismantled materials shall be the gross quantity obtained and not the net quantity considered for payment in schedule. The old and unserviceable materials to be retrieved from taking down/demolition/dismantling etc are considered in schedule of credit. No claim of contractor with regard to quality/position of old materials shall be entertained Srl No Description of item Qty Unit Assessed rate by department Remarks Rate in (Rs) Amount in (Rs) |
| 81 | Brick bats / PCC kerb stone |
| 82 | Old unserviceable brocken tiles of any description |
| 83 | Scrap iron |
| 84 | Old unserviceable point wiring copper/aluminium complete with steel conduit etc |
| 85 | Old unserviceable material such as flame proof switches,sockets, junction box,plug of any type. |
| 86 | Old unserviceable flood light fitting of any type and any size |
| 87 | Old unserviceable flame proof light fitting any type |
| 88 | Old unserviceable T/L any type |
| 89 | Old unserviceable material obtained from repair of exhaust/pedestal fans i.e. blade/bird catcher/wire guard/ball bearing/louvers etc. |
| 90 | Old unserviceable copper obtained from rewinding any type |
| 91 | Old unserviceable MCBs/ junction/ sunken boxes of any capacity/ description |
| 92 | Old unserviceable main switches/ MCB DBs of any capacity/ description |
| 93 | Old unserviceable sub main wiring 4 sqmm any type and any size |
| 94 | Old unserviceable sub main wiring 6 sqmm any type and any size Total amount of credit schedule 57395.0 Signature of contractor AGE (Contracts) For ACCEPTING OFFICER |