| 1 | Taking down ceiling (any type) and refixing them after repair with departmental materials, within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 2 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 3 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 4 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 5 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 6 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling. ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I. |
| 7 | Making 30 cm (12\\") dia bore upto 4 m depth below ground with hand augar of approved quality in ordinary soil true to plumd and without eccentricity in any stage of operation and disposal of the excavated earthupto 50 M lead |
| 8 | Providing single layer Naria- tiles in roof including cost of all labour and materials, taxes, all coplete as per building specification and direction of E/I. |
| 9 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 10 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I |
| 11 | Providing designation 75A one brick on edge soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plint level:1:2:4 (1 Cement : 2 Coarse sand (Zone-III) : 4 graded stone aggregate 20mm nominal size) |
| 13 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement-all work up to plinth level. 1:1.5:3 (1 Cement: 1.5 Coarse sand (Zone-III) : 3 graded stone aggregate) |
| 14 | Centering and shuttering including strutting, propping etc and removal of form for Foundations, Footings, bases of columns etc for mass concrete |
| 15 | Reinforced cement concrete work in walls (any thickness) including attached plasters buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc above plinth level upto floor five level excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 Cement: 1.5 Coarse sand (Zone-III) : 3 graded stone aggregate) 20mm nominal size |
| 16 | Centering and shuttering including strutting, propping etc and removal of form for columns, pillars, piers,abutments, posts and struts |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15º landings, balconies, shelves, chajjas,lintels, bands, plain window sills, stair cases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement: 1.5 Coarse sand (Zone-III) : 3 graded stone aggregate)20mm nominal size |
| 18 | Centering and shuttering including strutting, propping etc and removal of form for Lintels, beams, Plinth Beams, girders, bressumers and cantilevers |
| 19 | Renewing bamboo frame in roof with new and old bamboo, binding the same with wire string including cost of all labour and materials all complete as per specification and direction of E/I. |
| 20 | Providing designation 75A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I |
| 21 | Providing designation 75 A brick work in C.M(1 :6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of Screening materials, scafolding, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 22 | Providing 12mm thick plaster (1:6) with clean coarse sand of FM 1.5 including screening curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 23 | Providing cement flush pointing (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 24 | Prov Tor steel reinforcement of 8mm dia as per approved -do- TMT FE 500 (Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels,Bokaro and Vizag (RINL)) For 8mm Dia- |
| 25 | Prov Tor steel reinforcement of 10mm, 12mm and 16mm dia bars as per approved design and drawing -do-do- (b) 12mm (TMT Coil Fe 500)(Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels,Bokaro and Vizag (RINL)) For 10mm Dia- |
| 26 | Prov Tor steel reinforcement of 10mm, 12mm and 16mm dia bars as per approved design and drawing -do-do- (b) 12mm (TMT Coil Fe 500)(Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels,Bokaro and Vizag (RINL)) For 12mm Dia- |
| 27 | Prov Tor steel reinforcement of 10mm, 12mm and 16mm dia bars as per approved design and drawing -do-do- (b) 12mm (TMT Coil Fe 500)(Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels,Bokaro and Vizag (RINL)) For 16mm Dia- |
| 28 | Providing 12mm thick Cement Plaster (1:3) with 1.5mm cement punning in skirting/dado all complete as per direction of E/I |
| 29 | Supply, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I (Where materials is not supplied by the deptt.) |
| 30 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 31 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 32 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. ot finished welded type tubes POULTRY SHED Truss 60 mm RECTANGULAR HSS pipes 4 mm th |
| 33 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approvedquality for new work |
| 34 | Supply of CA sheet and labour cost for fitting and fixing CA sheet |
| 35 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 36 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required Including the costof EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 37 | Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . 4.0 mm(Cost of aluminium snap beading shall be paid in basic item): |
| 38 | Supplying/Fixing at site Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately). Steel wire fabric 0.9m wide rectangular mesh 50x25mm size weight not less than 7.75kg/sqm |
| 39 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 40 | Providing two coats of synthetic enamel paint & Providing primer one coat of red lead paint approved shade and made over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I |
| 41 | Providing two coats of synthetic enamel paint of approved shade and make over old wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 42 | S/F/F the following items of all complete job Bib Cock long thread(Rate=728.15) |
| 43 | S/F/F the following items of all complete job Towel rail |
| 44 | S/F/F the following items of all complete job Soap Container |
| 45 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 46 | Providing and laying Mud mortar made with local clay good earth on wall surface with proper finishing. |
| 47 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 48 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 49 | Supplying, fitting and fixing M.S. grill gate with M.S. grill made of 20X6mm M.S. flats or 16mm M.S. square bars fitted on 25X25X6mm M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 50 | Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 51 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shad of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 52 | Taking down old door and window shutters including stacking serviceable materials within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 53 | Taking down chaukhats in windows including stacking serviceable materials within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 54 | Providing and fixing ridges and hips in fibre cement high impact polypropylene reinforced roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. |
| 55 | Finishing walls with Acrylic Smooth exterior paint of required shade :Two or more coat applied @ 1.67 ltr/ 10 sqm)on existing cement paint surface |
| 56 | Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other S.S.approved make with 100mm H.C.I. ‘p’ trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S.equivalent make, complete with all fittings,C.I. or C. C.brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. (A) 580 mm. long 10 ltr low PVC Cistern |
| 57 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 58 | Providing 50mm thick cement concrete flooring (1:1.5:3) with 20mm to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction E/I |
| 59 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 60 | a) Sand Lead 22 Km |
| 61 | b) Stone Chips Lead 22 KM |
| 62 | c) Bricks Lead 6 Km |
| 63 | d) Earth lead up to 3 Km |
| 64 | Wiring for light point/fan point/ Exhaust fan point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required. Group A |
| 65 | Wiring for circuit/submain wiring along with earthwire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 66 | Wiring for circuit/submain wiring along with earthwire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire |
| 67 | Supplying and fixing suitable PVC/G.I box with modular plate and cover in front on surface/recess ,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch ,connection etc as required |
| 68 | a)Supplying & fixing of following modular type switch/socket on the existing modular plate and switchbox including connection etc as required 5/6 Amp switch |
| 69 | b)Supplying & fixing of following modular type switch/socket on the existing modular plate and switchbox including connection etc as required 5/6 Amp socket |
| 70 | c)Supplying & fixing of following modular type switch/socket on the existing modular plate and switchbox including connection etc as required electronic fan regulator |
| 71 | Supplying and fixing following size /module ,GI box along with base & cover plate formodular switches in recess etc as required. 6 module |
| 72 | Supplying and fixing following way single pole and neutral ,sheet steel MCB distribution board 240 volts on surface/recess complete with tinned copper bus bar ,neutral bar etc as required.(but without MCB/RCCB/ISOLATOR) 8 way ,Double door |
| 73 | Supplying and fixing following 240 volts C series ,miniature circuit breaker suitable for inductive loads of following poles in existing MCB DB complete with connection as required. 6/32 amps,Single Pole |
| 74 | Supplying and fixing following 240 volts C series ,miniature circuit breaker suitable for inductive loads of following poles in existing MCB DB complete with connection as required. 6/32 amps,SPN |
| 75 | SITC of following rating LED FLOOD Lighting luminaries with pressure die cast housing and toughned glass cover (IP66 protection) in existing pole/pipe for supply voltage 100-270V AC,50Hz.Luminaries shall be confirm to IS :10322 part -5/section -5 and shall be complete with all necessary accessories as required. 90/100 W LED Flood Light |
| 76 | Supply installation ,testing and commissioning of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated ,copper wire suitable for 230 volt 50 Hz ,single phase supply etc as required. 1200 mm (48”)Ceiling Fan |
| 77 | Supplying, fitting and fixing of following way single pole and neutral, sheet steel MCB DB board 240 volt without MCB/ isolator 6 way Single door |
| 78 | Supplying, fitting and fixing of following way single pole and neutral, sheet steel MCB DB board 240 volt without MCB/ isolator 2 way Single door |
| 79 | Supplying and fixing following 240 volts C series ,miniature circuit breaker suitable for inductive loads of following poles in existing MCB DB complete with connection as required. 32 amp DP |
| 80 | Earthing with copper plate 600mm X 600mm X 3 mm thick including accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipe etc(with charcoal or coke and salt) as required. |
| 81 | Supplying and laying of 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required. |
| 82 | 50/60 W LED Flood Light (for internal) |
| 83 | 90/100 W LED Flood Light(for external) |
| 84 | Supply of 20/22 watt LED Batten |
| 85 | FR PVC insulated 3 core 4 sq.mm copper wire (for flood light & Service line) |
| 86 | Supplying and fixing of cable junction box complete with connection as required make-sintex or equivalent. |
| 87 | Supplying and fixing of 15/16 Watt Led Bulb |
| 88 | 1200mm(48”)BLDC5 star rating 32 W |
| 89 | Supply and fixing of 12”(300mm) metal exhaust fan. |
| 90 | Add GST @ 18% |
| 91 | Add LWF @1 % Please Enable Macros to View BoQ information |