| 1 | SITC of Lift and related electrical work ---Supply and Erection of 680Kg 13person ,2stop (G+1), Lift Speet 1 MPS ,travel height 3.75m , machine room less, head room -4500mm, pit depth1500mm, shaft dimensions WxD-2000mmx2500mm , car dimension WXDXH-1050mmx2100mmx2200mm, car door size WxH 900mm x2000mm ,, , Drive-V3F Regenerative (Close loop ) , Powe r supply -400/415V (3 phase AC ), operation - Full collective operation , Car group one car (Simplex) , Automatic Rescue operation (Technical detail as per attached annexure) |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C DSR No.1.10.3 |
| 3 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. DSR 1.31 |
| 4 | Supply and fixing 3 pin 5A celling rose on the existing Junction box including connection as required DSR 1.33 |
| 5 | Supply and fixing of 4way VTPN with additional metalic door suitable for For MCCB incomer (Analysis Rate) |
| 6 | 100 A,30KA,FPMCCB (Make - Havells/ Anchor/ Legrand) DSR 2.2.13 |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole(Make - Havells/ Anchor/ Legrand) DSR 2.10.1 |
| 8 | Supply of Fresh air fan 300 mm (GeM) |
| 9 | Supply and fixing of water tight oblong 10 watt LED bulk head luminaries having die casting housing with driver set confirming to IP65 and above protection 1K 08 , high purity transmisivity UV stabilized non yellowish diffuser / for uniform light ditribution , detachable driver set , openand short circuit protection . 1200 system lumens,>120Lm/W, PF>0.95, THD<10%, CRI>80, sheet thickness min 0.8mm, tube with aluminium heat sink, >300V over voltage protection, 4KV internal Surge Protection with 5 year warrantee in complete in all espect . DSR 23.11 |
| 10 | Installation of Ex fan ( Fresh air fan ) in the existing opening including making good the damage connection ,testing ,commissioning etc as required DSR 1.50.1 |
| 11 | Extra for fixing of Louvers/ shutters completed with frame for ex fan DSR 1.51 |
| 12 | Providing Laying of GI pipe in ground complete with GI fitting including trenchining (75 mm depth ) refilling etc as required 100mm DSR 15.13.3 |
| 13 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc Size-.50 sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) S.No. 20a.1.12 |
| 14 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. Size- 50 sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) DSR 2111 |
| 15 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharg Size-50 Sqmm (Make - Dowells or equivalent) DSR 2206 |
| 16 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required. DSR 5.4 |
| 17 | S/F 2 No. 6 SWG GI wire DSR 5.18 |
| 18 | Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect. DSR 5.15 |
| 19 | Supply and fixing of fire extinguisher ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work (Rate Analysis) |
| 20 | Supply and fixing of fire extinguisher ,CO2 Type6.5kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work. (Rate Analysis) |
| 21 | Modification and repair of of Lift Pit - Digging the space of the Lift Pit. Supplying, cutting, placing and banding of TMT reinforcement of relevant size in complete pit area Size of Bar - 10mm & 8mmReinforced Cement concreting work in lift pit baseDepth - 300mmSlab CuttingSupply/installation/dismantling of required shuttering (As per Quotation) |
| 22 | Repairing/modification of Lift entrance & Lift shaft wall Breaking/cutting/chipping of 250mm wide wall for lift entrance wall opening RCC lentil casting for lift door fastening Size 230mm width * 230mm depth Nautch construction for lift door Size 70mm depth * 230mm width Modification and repair wall at Gnd floor Internal & external plastering Lift entrance finishing work after fixing Lift door marble work (As per Quotation) |
| 23 | ISMB supply & Installation (As per Quotation) |
| 24 | Smoke window cutout and Supply/Fixing of wire mesh (As per Quotation) |
| 25 | GST @ 18% Please Enable Macros to View BoQ information |