|
| 1 | Dismantling posts or struts (Wood or RCC) any section, including taking out embeded portion and making good disturbed ground, including any type fencing all as specified and directed. |
| 2 | M & L for MS work as in swan neck / brackets etc for fencing post & strut in fencing, Flatg iron for securing chain link fencing etc including cutting tops to shape as directed, drilling holes, riveting for wires etc including all necessary drilled bolting or riveting etc and similar work conforming to Fe290 Gde E-165 including dismantling old mild steel work complete all as specified and directed. |
| 3 | Dismantling fencing wire mesh, any type or position complete all as specified and directed |
| 4 | Fixing only Chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provission of binding wire complete all as specified and directed. |
| 5 | Supply only Chain link MS galvanised 4mm dia (wt. not less than 4kg) fencing any size or type all as specified and directed . |
| 6 | M&L for 10mm dia and over Mild steel round bars (for securing chain link fencing) Grade Fe-410 (Gde E-250) quality A, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 7 | S & F in repair galvanized 2 stranded steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and fixing to any type of standard hooks, including securing and tying at crossing with and provision of galvanized mild steel wire staples or steel pins etc complete all as specified and directed. |
| 8 | Tightening /restraining and resecuring of old existing barbed wire including making good staples etc in same position complete all as specified and directed . |
| 9 | Removing of concertina coil any size and any type in any position and refixig in the same position etc complete all as specified and directed . |
| 10 | S&F in repair of concertina coil size of any size in one rows between the double layer fencing including all fixing arrangement complete all as specified and directed . |
| 11 | Dismantiling of wrought iron or mild steel work any desc not otherwise provided for all as directed |
| 12 | M & L for MS work as in Grills/doors, gratings, etc with ends of bars shouldered and /or riveted, or forged into spikes, framed guard bars, barred iron doors, ladder framed balusters, walk way, railings, frame work of water tanks ad similar work conforming to Fe290 Gde E-165 including ornamental wk in door complete all as specified and directed. |
| 13 | M & L for Preparing old painted steel & iron surfaces of any description n.exc over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 14 | M & L for Preparing New painted steel & iron surfaces of any description n.exc over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 15 | M & L for Preparing new steel & iron surfaces of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 16 | M & L for Preparing old painted steel & iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 17 | M&L Running welding exc 6mm thick welded metal etc complete all as specified and as directed. |
| 18 | M&L for brick work with sub class 'B' bricks , straight or curved on plan exc. 6 m mean radius built in CM 1:6 including demolition of old brick work complete all as specified and directed. |
| 19 | Description same all as per item No 18 above but, except brick including demolition of old brick work complete all as specified and directed. Note : Old retrieved bricks obtained from item no 18 & 19 in serviceable conditions shall be used in the work. |
| 20 | M&L for stone walling of random rubble masonry uncourse, well bonded, bedded and solidly hearted built in CM (1:6) including demolition of old brick work complete all as specified and directed. |
| 21 | All as per item No 20 here-in-before but, except stone including demolition of old stone masonery complete all as specified and directed.Note :- Old retrieved stones obtained from item No 20 & 21 in serviceable condition shall be used in the work). |
| 22 | M&L for flush pointing to random rubble masonry/stone walling in cement mortar (1:4) complete all as specified and directed. |
| 23 | Taking down cement plaster on brick surface or stone including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 24 | M&L for 15mm thick rendering other than fare face of brick/stone masonry walls in CM 1:6 finished even and smooth without using extra cement all as specified and directed. |
| 25 | M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth without using extra cement all as specified and directed. |
| 26 | M&L for Preparation of newly Plastered surfaces and applying three coats of white wash complete all as specified and directed. |
| 27 | M&L for Preparation of newly plastered surface and applying two coat of weather coat exterior emulsion white or tinted by the use of rollers over a coat of primer as approved complete all as specified and directed. |
| 28 | M&L for Preparing old decorated plastered or unplastered surfaces of external walls and applying one coat of exterior emulsion paint by the use of rollers complete all as specified and directed. |
| 29 | M&L for preparation of old plastered surfaces of walls and applying one coat of white wash complete all as specified and as directed. |
| 30 | Demolition of cement concrete ( unreinforced) ground floors and pavings n. exc 15 cm thick below or above ground level and removing the demolished material to a distance exc 500 m but not exceeding 1.5 km and depositing where directed, complete all as specified and directed. |
| 31 | M&L for PCC (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in surface channel etc complete all as specified made to shape and size as directed. |
| 32 | M&L PCC 1:4:8 Type D-2 (using 40mm graded Stone aggregate) as in foundation filling and mass concrete all as specified and directed. |
| 33 | M & L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in coping including necessary form work complete all as specified and directed. |
| 34 | M&L for PCC (1:3:6) type C-1, using 20mm graded stone aggregate as in foundation Filling mass concrete complete all as specified and directed. |
| 35 | Extra for forming fair finish drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stooped ends etc complete all as specified and directed. |
| 36 | Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto complete all as specified and directed. |
| 37 | M&L for 100 mm thick plain cement concrete (1:2:4) type B2, using 40 mm graded stone aggregate as in floor finished and pavings complete all as specified and directed. |
| 38 | Dismentling Stone slabs and tiles of any description or thickness in floors, aprons laid bedded and pointed in mortar etc complete all as specified and directed. |
| 39 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm thick screed bed with bedding layerin CM (1:4) including dismantling of granite/tiles complete all as specified and directed. |
| 40 | M&L for 75 mm thick plain cement concrete (1:3:6) type C2, using 40 mm graded stone aggregate as in path/sub base etc complete all as specified and directed. |
| 41 | M&L for 60 mm thickness Machine pressed precast concrete interlocking paver block any shape and size of M-35 Grade confirming to IS 15658-2006 with grey cement and no pigment complete all as specified and as directed. |
| 42 | M&L for Sand filling under floors to receive interlocking paver blocks incl consolidation complete all as specified and as directed. |
| 43 | M&L for precast RCC (1:2:4) type B-1 (using 20mm graded aggregate) as in shelves, cover slabs for manholes/drains etc set in cement mortar (1:6) including necessary form work etc including demolition of old cover slab complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately) under appropriate item of Sch ‘A’ |
| 44 | M&L for 10mm dia and over Mild steel TMT bars/round bars (for securing chain link fencing), cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 45 | M&L for 600mm bore reinforced concrete pipes class NP-2 ,laid and jointed complete with collars complete all as specified and directed including concrete bed to drain pipe incl packing under and completely surrounding pipes with cement concrete 1:3:6 mix,type C-2(using 40mm geaded stone aggregate) and dismantling of old RCC pipe & necessary excavation complete all as specified and as directed. Please Enable Macros to View BoQ information |