| 1 | 2 1 Supply, fixing & eraction of built up Cantilever Structure 6 m span comprising of one vertical posts of 16.00 M height made up of 300 mm NB heavy class MS pipe as vertical member welded with 10 mm VMS plate at top & 12 mm M S plate at bottom. The horizontal Truss shall comprise of 50 mm dia heavy class M.S. pipe and 40 mm dia heavy MS pipe as bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant. The work includes construction of RCC Foundation of size 0.90×0.90x1.50 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1:3:6 cement coarse sand and 40 mm gauge stone ballast and RCCM25 grade concrete including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering. The lateral vertical clearances and complete Installation work shall be as per relevant clauses of MORT&H specification section 800 and IRC 67 2012 complete in all respect The Rates shall include cost of design fabrication, supply, transportation, Local shifting Erection of Signage structure using crane, inclusive of all taxes etc. all T&P machine, material and labour required for proper completion of work as per direction of Engineer-in-charge as per MORTH No-502 (AS Per MORT&H Specification) (Including labour Material T&P etc. complete as per direction of E/I & also including all taxes. Labour cess but excluding GST) |
| 2 | Providing & foxing of reflective signs with a corrosion resistant 4 mm thick with 04 to 0.5 mm both side aluminium skin aluminium composite panel face to be fully covered with High Intensity prismatic sheeting type V as per IRC-67:2012 retro reflective sheeting with back frame MS angle of 35x35x5 mm. Legends, letters, numerals and borders etc should be as per MoRTH specification No-801.3.7 The sheeting shall have a pressure-sensitive adhesive of the aggressive tack type requiring no heat solvent other preparation for adhesion to a smooth clean surface, in a manner recommended by the sheeting manufacturer. The ACM (Aluminium Composite Materials) shall be fixed on the Back frame MS Angle with riveting. Micro prismatic type IV Retro reflective sheeting confirming to ASTM D4956-09 shall be Pressure fixed. The Retro reflective sheeting shall be tested for a certificate of having the sheeting lested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, finer removal, adhesion, impact resistance, specular gloss and fungus resistance. 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & Proof of the same Report shall be uploaded which quoting tender. The rate shall include all materials, labour, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge as per MORTH No-801 (AS Per MORT&H Specification) (Including labour Material T&P etc. complete as per direction of E/I & also including all taxes. Labour cess but excluding GST) |
| 3 | Supply, fixing & eraction of built up Overhead Structure of 12M-15M span comprising of two vertical posts of 6.00 M height made up of 300 mm NB heavy class MS pipe as vertical member welded with 10/mm MS plate at top & 12 mm M S piate at bottom. The horizontal Truss shall comprise of 50 mm dia heavy class M.S. pipe and 40 mm dia heavy M S pipe as bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant. The work includes construction of RCC Foundation of size 0.90×0.90x1.50m of required depth as per site condition for bullt up structure including Earth work in excavation 100 mm thick Lean Concrete in 1:3:6 (cement coarse sand and 40 mm gauge stone ballast and RCC M-25 cement concrete including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering. The lateral vertical clearances and complete. Installation work shall be as per relevant clauses of MORT&H specification section 800 and IRC 67 2012 complete in all respect. The Rates shall include cost of design, fabrication, supply, transportations, Local shifting Erection of Signage structure using crane, inclusive of all taxes etc. ail T&P machine, material and labour required for proper completion of work as per direction of Engineer-in charge as per MORTH No-802 (AS Per MORT&H Specification) (Including labour Material T&P etc. complete as per direction of E/I & also including all taxes. Labour cess but excluding GST) |
| 4 | Supply & fixing of reflective sign board (Single side) of size 1.50x1.20 m retro reflective sheeting of HIP grade type-IV, the board shall be fixed on 50mm SS 304 grade pipe and reflective sheet on 4 mm thick, ACM sheet of standard make as per MORTH specificaton. The Board shall be fixed using 2 man post 45x45x60 cm cement concrete foundation. The stainless steel joint welding of SS pipe work shall be band and grinder property including bufting so an to give uniform shining at weded joints. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively. certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67.2012. Legends, letters, numerals and borders etc should be as per MoRTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded while quoting tender, as per MORTH No-801(8.60) Base.(AS Per MORT&H Specification) (Including labour Material T&P etc. complete as per direction of E/I & also including all taxes. Labour cess but excluding GST) Please Enable Macros to View BoQ information |