| 1 | Schedule 'A\\" (B/R Portion)Surface Dressing n.exc (not exceeding) 15 cm deep and getting out in soft and loose soil. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge in all kind of soil |
| 3 | M & L PCC (1:2:4) type B2 for Footing, Plinth beam |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Soft / loose soil. |
| 5 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate For Foundation, Including rafts as Mass Concrete |
| 6 | Use & waste Form work for rough finished surfaces of concrete measured flat for foundation. |
| 7 | S & F Steel reinforcement (CRS bars) 10mm dia & over of Grade Fe 500d incl cutting, bending, binding & placing in position with binding wire. |
| 8 | Ditto but 5 to 10mm dia in stirrups, spacers & binders. |
| 9 | M & L RCC-M-30 (Design Mix) using 20mm graded aggregate for Column ( upto plinth Top) |
| 10 | Use & waste Form work for rough finished surfaces of concrete measured flat for Column finished fair flat surfaces (up to Plinth Top) |
| 11 | M & L RCC-M-30 (Design Mix) using 20mm graded aggregate for Plinth Beam. |
| 12 | Use & waste Form work for rough finished surfaces of concrete measured flat for Tie beams finished fair flat surfaces |
| 13 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate for Column From Plinth Top to G.Floor Slab level. |
| 14 | Uuse & waste Form work for rough finished surfaces of concrete measured flat for Column finished fair flat surfaces |
| 15 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate for Beam. |
| 16 | Use & waste Form work for rough finished surfaces of concrete measured flat for Beam. |
| 17 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate for Column From G.F Slab Level To F.Floor Slab level |
| 18 | Use & waste Form work for rough finished surfaces of concrete measured flat for Column finished fair flat surfaces |
| 19 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate for First floor Slab Beam. |
| 20 | Use & waste Form work for rough finished surfaces of concrete measured flat for First floor Slab Beam. |
| 21 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate for First floor Slab. |
| 22 | Use & waste Form work for fair finished surfaces of concrete measured flat for First floor Slab. |
| 23 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate for Rcc Parapet wall. |
| 24 | Use & waste Form work for fair finished surfaces of concrete measured flat for Rcc Parapet wall. |
| 25 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate for Rcc Fascia/downward pardi. |
| 26 | Use & waste Form work for fair finished surfaces of concrete measured flat for Rcc Fascia/downward pardi. |
| 27 | M & L For Pre-Cast Cement Concrete Block Masonry, Type C1 (1:3:6), ( 20mm Graded Aggregate) With Solid Blocks, Exc. 10 CM in Width And Setting in CM (1:6), Complete |
| 28 | M&L rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, Complete all as specified and directed. |
| 29 | M & L 5mm Thick Cement Plaster in CM (1:3), 3mm Thick White Cement Putty |
| 30 | M&L rendering 15mm thick in CM 1:4 on fair faces of masonry surfaces finished even and smooth without using extra cement, Complete all as specified and directed. |
| 31 | Supply only WPC |
| 32 | Two coats of Oil Bound Distemper emulsion over one coat of primer on walls |
| 33 | Two coats of Oil Bound Distemper emulsion over one coat of primer on ceiling |
| 34 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 35 | M & L RCC-M-30 (Design Mix) using 20mm graded aggregate For Staircase |
| 36 | Use & Waste Form work for fair finished surfaces of concrete measured flat For Staircase |
| 37 | Landing 37 M & L RCC-M-30 (Design Mix) using 20mm graded aggregate for staircase Landing |
| 38 | Use & Waste Form work for fair finished surfaces of concrete measured flat for landing |
| 39 | S&F For Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 40 | 4mm Thk Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required. |
| 41 | S&F Plain solid, straight chowkats and frames of second class soft wood (Kail) Wrought Framed rabatted on the solid rounded or chamfered, put together with glue pinned at joints Complete all as specified and directed. |
| 42 | S & F 35mm Thk Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides |
| 43 | S & F 200 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed |
| 44 | S & F 150 mm long Aluminium handles, cast type, anodised |
| 45 | S & F 100 mm long Butt hinges, heavy weight, cold rolled mild steel, and fixed |
| 46 | M & L For Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface. |
| 47 | M & L For 100mm Thick PCC type A-1, 1:1.5:3 (20mm graded aggregate) |
| 48 | M & L For 75mm Thick PCC type D-2, 1:4:8 (40mm graded aggregate) |
| 49 | M & L For Bedding Layer of mortar CM(1:4) 20 mm thick for laying floor finishes |
| 50 | M & L For Machine cut kota stone slab flooring 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 51 | M & L For bedding layer of mortar CM (1:3) 10mm thick for laying floor finishes |
| 52 | M & L For Kota stone 20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 53 | M & L For Bedding Layer of mortar CM(1:4) 20 mm thick for laying floor finishes |
| 54 | APP based polymeric membrane minimum weighing 3.5kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified |
| 55 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 56 | M & L 75mm thick Plinth Protection PCC (1:3:6) type C1 using 40mm graded aggregate (0.75 m wide). |
| 57 | M & L For 100 Thick Hardcore of guage n exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface |
| 58 | S&F Mild steel bolts for locking/securing arragngments for GDT as per site requirment. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut.exc 15cm and n exc 30cm long all as specified |
| 59 | Schedule 'A\\" (E/M Portion)Material and labour point wiring with 1.5 sqmm (nominal cross section area) single core PVC insulated unsheathed cable of 1100 Volts grade (FRLS) multistrand with copper conductor drawn through and including non metallic, rigid PVC conduit of adequate size with all fittings and conduit accessories concealed in wall/ceiling/floor/roof etc. including 2 mm thick modular box with modular cover plate and frame for housing the switches, socket outlets including provision of 1.5 sqmm green in colour PVC insulated copper conductor single core multistrand (FRLS) for earth continuity conductor and connected to common earth dolly all as specified for the following:- |
| 60 | One light point control by one switch |
| 61 | One ceiling fan/exhaust fan contrcl by one switch |
| 62 | One security light point control by one switch |
| 63 | -ditto- all as per item No 59.00 above but wire 2.5 sq mm cable for One 3 pin socket 5 Amps on the same board with other switches |
| 64 | -ditto- all as per item No. 59.00 above but wire 2.5 sq mm cable for One 3 pin socket 5 Amps socket as independent board |
| 65 | ditto as per item No. 59.00 above but wire 4.0 sq mm cable for switch socket outlet 3 pin 15 Amps with 4.0 sq mm as earth continuity conductor. |
| 66 | S & F Modular switch 1 way 6A, 1 module all as specified and directed by EIC. |
| 67 | S&F modular socket, Socket, 6A - 2/3 pin combined 2 module all as specified and directed by EIC. |
| 68 | S&F Socket 16A - 2/3 pin combined 2 module, all as specified and directed by EIC. |
| 69 | S&F Modular switch 1 way 16A, 1 module all as specified and directed by EIC. |
| 70 | Supply and fix ceiling rose three terminal Il as specified and directed by EIC. |
| 71 | Supply and fixing Modular fan regulator120Watt, 2- module, AC 240 Volts complete. |
| 72 | Supply and fix ceiling fan 1200 mm sweep 230 V AC, 5 Star rated with brushless direct current motor (BLDC) complete including connecting up with 3 core cord flexible from ceiling rose to fan etc all as specified and directed by Engr-in-charge. |
| 73 | Supply and fixing LED light fitting 1x 20 Watt, 220 V AC decorative box type with driver, holder including LED tube light connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. |
| 74 | Supply and fixing LED street light fitting 70 Watt, 230 V AC outdoor type with high pressure die aluminium housing and heat resistant complete with driver, lamp, with impact and corrosion resistanct including thermal management in multiple optics, including suitable size mounting bracket, clamps,nut, bolts complete with IP 65/66 protection all as specified and directed by Engr-in-Charge. |
| 75 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp & connecting up with flexible copper conductor cable with sultable size complete all as directed by Engr-In-Charge. |
| 76 | S&F MCCB DB VERTCLE TYPE made of sheet steel, powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade, 415 Volts TPN with 8 way Double door complete all as specified and as directed. |
| 77 | S&F MCCB 4P 125 Amps, 415Volts, 16-18 KA complete all as specified and as directed. |
| 78 | S&F MCB DB made of sheet steel, powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade, 415Volts TPN with 6 way Double door |
| 79 | S&F MCB TPN 63 Amps, 415Volts, 16 KA complete all as specified and as directed. |
| 80 | S&F MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 25 to 63 Amps |
| 81 | S&F MCB SP 6-32 Amps 'C' Series complete all as specified and directed. |
| 82 | M&L for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 4 Single core of size 6 Sqmm, earth continuity conductor of size 1X 6 Sqmm to be drawn through and in concealed conduit non metallic, rigid PVC conduit of adequated size with all fittings and conduit accessories complete all as directed by Engineer in Charge.Notes:- (i) four wires of 6 sqmm and one wire of 6 sqmm and one run of PVC conduit /casing caping shall be measured as one unit. |
| 83 | Supply and fixing Mild steel Galvanized Coating Cable tray perforated type of size 1 feet width along with cover for carrying of cables of any size fixing on wall/angle iron with all necessary fixing accessories (bracket, nut bolts, washer, fastner) complete all as specified and as directed by Engineer-in-Charge. |
| 84 | S&F XLPE insulated armoured and pvc sheated heavy duty electric cable size 3.5 core,50 Sqmm cross sectional area with aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendment laid in tranches passing through pipes /ducts / saddle on wall with clamps including testing complete note- rate is inclusive of cable gland & cable lugs |
| 85 | S& F laying of Double Walled Corrugated (DWC) HDPE pipe of 40/32 mm outer/inner dia size of conforming to IS 16205 Part -24 including necessary bends, coupling,tees, reducers, spacers,end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wail/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge Make:-ASTRAL TELEREX /eqivalent as approved by GE Please Enable Macros to View BoQ information |
| 86 | S& F laying of Double Walled Corrugated (DWC) HDPE pipe of 40/32 mm outer/inner dia size of conforming to IS 16205 Part -24 including necessary bends, coupling,tees, reducers, spacers,end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wail/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge Make:-ASTRAL TELEREX /eqivalent as approved by GE Please Enable Macros to View BoQ information |