| 1 | Dismantiling / taking down LED 40/65/70/100/150W street light / security lights/High Mast of any capacity & description from exising LT pole/walls, at any height and refixing the fittings in existing / another location after repair work or carrying to MES store complete all as specified and directed.Note :-(i) Replacement of defective parts accessories shall be measured and paid separately under relevant item of Sch 'A' as supply and fix in repair.(ii) Transport and T & P i.e. Ladder, spanners or any other equipment for repair of street light shall be provided by Contractor and cost for the same deemed to be included in respective item of Sch 'A' |
| 2 | Material and labour for street light brackets made of 32 mm dia G.I. Pipe light grade in shape and angle as directed not exceeding 1.5 mtrs in length fixed to pole with suitable size of M.S. clamps made of M.S flat of size 40 mm x 3 mm, 2 Nos, M.S nut & bolt with cup washers and dismantling old rusted/unserviceable bracket with its rusted clamps and nut bolts complete all as specified and as directed. |
| 3 | Supply and fix in replacement street light timer analog clock type with suitable for connection with three phase supply and connected to existing contact for cotntroling complete all as specified and as directed. Make: Havell's Cat Part No. DHTED15016 or equivalent of Indoasian/CG |
| 4 | Supply and fix in repair 1100 volts grade PVC insulated PVC sheathed cable weather proof multisranded/ solid aluminium conductor 3 core 1.5 sqmm from jn box to connector of fitting complete all as specified and as directed. |
| 5 | Supply and fix in repair in existing street light panel and connection with bus bar out going cable with copper wire with MCCBs of the undermentioned sizes complete all as specified and as directed.Make- Havell's/CG/L&T/Schneider |
| 6 | MCCB 4 pole 'C' curve 100 Amps, 415 Volts AC, 16 kA |
| 7 | MCCB 4 pole 'C' curve 40-63 Amps, 415 Volts AC, 16 kA |
| 8 | Supply and fix in repair in existing street light panel and connection with bus bar out going cable with copper wire with power contactors 3 phae, 415 V, 40 Amps, in repair complete all as specified and as directed Make: L&T Model ML-3 SS90721 or its equivalent in Schinder/ ABB / Siemens/ HPL |
| 9 | Supply and fix in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed |
| 10 | Supply and fix in repair/replacement for kiosk box for luminaries, weather proof made out of PVC/HDPE /FRP housing fire retardant, non fusing, shock & rust proof, single piece molded and cover with hinged door, pole mounting type comprising of aluminum TPN bus bar of 20 Amps of minimum size 300x250x150mm, fixed on pole with MS, clamps 30x5mm with necessary nuts, washer including MCB 16 Amps for out going complete all as directed. Note :- Rate of TPN bus bar and MS clamp inclusive in item rate |
| 11 | Supply and fix in replacemet of High efficiency long life CREE LED chip in modules of following capacity with Ra>75 and lumen efficacy of >95 lum/watt or equivalent suitable forsuitable for LED light fitting complete all as specified and directed. Make : Philips/Shakti/Bajaj/ Havells/CG/Surya |
| 12 | 100 to 150 Watt fittings. |
| 13 | 50 to 90 Watt fittings. |
| 14 | 40 to 45 Watt fittings. |
| 15 | Supply and fix in replacement LED street light fitting driver of exisiting make and model of rating 40 Watt complete all as specified and as directed. |
| 16 | Supply and fix in replacement LED street light fitting driver of exisiting make and model of rating 60 W to 90 Watt complete all as specified and as directed. |
| 17 | Supply and fix in replacement LED street light fitting driver of exisiting make and model of rating 100 W to 150 Watt complete all as specified and as directed. |
| 18 | Supply and fix in replacement of LED Post top of 25 Watt Integral pole mounted decorative LED with IP-65 protection complete fixed on existing post, all as specified and directed.Make-Havell's Cat part no-RUBYPT25WLED830SSYMTOPC, or equivalant of Crompton / Philips /BAJAJ) |
| 19 | Material and labour for preparation and painting 04 nos band / strips with blue and white paint alternately all around the HT/LT/street light pole with synthetic enamel paint at a distance of 30 cm and painting both side for numbering with black enamelled paint and writing LT/ PL No on both side of pole with white enamelled paint of complete all as specified and directed . |
| 20 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in soft/ loose soil, for laying of under ground electric cable complete all as specified and directed. |
| 21 | Taking out LT UG cables of any size by excavation and earth work in any type of soil, removing bricks or PCC cover of any size complete all as specified and directedNote:- (i) Excavation, Joints & Jointing materials, new cable, additional bricks/PCC Covers, sand shall be measured & paid for separately. |
| 22 | Taking out serviceable unreinforced precast concrete cable covers Class LV type I, flat size 250mm x 150mm x 40mm laid transverse to cable complete all as specified and directed. |
| 23 | Relaying old serviceable under ground LT cable of any size obtained from item 1 above complete all as specified and directed |
| 24 | Supply and lay, jointing and testing in repairs/replacement of LT cable of size 16 Sqmm 4 core XLPE insulated, armoured, heavy duty with multi stranded aluminum conductors, 1100V grade, laid in trenches / ducts / through GI pipe fixed to pole complete all as specified and directed.Note:- Excavation earthwork, cable covers, sand cushioning and GI protection pipe shall be measured and paid separately. |
| 25 | Material and labour for river bed sand used in trenches/ ducts 08 cm under cable and 15 cm above the cable for cushioning/protection to cable and get thick 18cm after hand punning complete all as specified and directed |
| 26 | Laying only serviceable un-reinforced precast concrete cable cover class LV, Type 1, flat, of 250 mm x 150 mm x 40 mm obtained from trenches, abetting each other with gap between adjacent slab not exceeding 10 mm over for cable protection complete all as specified and directed. |
| 27 | Supply & laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over for cable protection complete all as specified and directed. |
| 28 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed. |
| 29 | Removing excavated surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 30 | Supply, fixing and testing LT cable jointing kit straight through type heat shrinkable suitable for cable PVC /XLPE insulated armoured heavy duty aluminum conductor 1100 volts grade LT cable of size 3.5/4 core 16 to 50 sqmm and including taking out cable from faulty portion in any situation/position complete all as specified and directed. |
| 31 | Disconnect cable of street light of any core, cutting its end, arrange necessary length from loop, fix neccassary lug in every core, cable connect in kiosk box or in LED street light and makes cable servicable etc complete all as specified and directed. |
| 32 | Supply and fixing in repair LED flood light fitting 210 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed Please Enable Macros to View BoQ information |