| 1 | Excavation in soft/loose soil trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out incl old U/s cable cover of any type, taking out/laying/cleaning/repairing of CI/GI pipe line, cable etc including making good to disturbed surfaces, complete all as specified and directed. |
| 2 | Returning, filling in & including spreading, levelling & well ramming in layers not exceeding 25 cm thick as in soft/loose soil, complete all as specified and directed. |
| 3 | Removal of surplus soil to a distance not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 mtr above ground level, complete all as specified and directed. |
| 4 | Taking up unserviceable CI/DI rusted/ broken pipe line (including all fittings) with spigot and socket/ Flanged ends for reusing and removal of unserviceable part from the site including burning out joints and recovering lead complete all as specified and directed for the following sizes/bores of pipes:-(a) 200mm bore dia(Earth work shall be measured and paid separately). |
| 5 | (b) All as per item No. 4.00 here-in-before but 150mm bore dia |
| 6 | (c) All as per item No. 4.00 here-in-before but 100mm bore dia |
| 7 | (d) All as per item No. 4.00 here-in-before but 80mm bore dia |
| 8 | Laying only in trenches DI/ CI pipe with spigot and socketed ends complete after cleaning properly/thoroughly & removal of all blockage removing all silt and deposited organics inside using bamboo or rod with brush, complete all as specified and directed for the following sizes/bore of pipes :-(a) 200mm bore dia |
| 9 | (b) All as per item No. 5.00 here-in-before but 150mm bore dia |
| 10 | (c) All as per item No. 5.00 here-in-before but 100mm bore dia |
| 11 | (d) All as per item No. 5.00 here-in-before but 80mm bore dia |
| 12 | Supply & laying in trenches ductile iron (DI) pipe with spigot and socketed ends centrifugally cast class 'K-7' in any length laid in trenches, complete all as specified and directed for the following sizes/bore of pipes (DI fittings and jointing materials shall be measured and paid separately) :-(a) 200mm bore dia |
| 13 | (b) All as per item No. 6.00 here-in-before but 150mm bore dia |
| 14 | (c) All as per item No. 6.00 here-in-before but 100mm bore dia |
| 15 | (d) All as per item No. 6.00 here-in-before but 80mm bore dia |
| 16 | Taking up or down steel water tubing and connections including clearing the pipes free from scaling for reusing and removal of unserviceable part, complete all as directed for the following sizes :- (a) 80 mm dia boreNote :- Excavation will be measured and paid separately |
| 17 | (b) All as per item No. 7.00 here-in-before but 50mm dia bore |
| 18 | (c) All as per item No. 7.00 here-in-before but 40mm dia bore |
| 19 | (d) All as per item No. 7.00 here-in-before but 25 mm dia bore |
| 20 | (e) All as per item No. 7.00 here-in-before but 20 mm dia bore |
| 21 | (f) All as per item No. 7.00 here-in-before but 15 mm dia bore |
| 22 | Relaying/ refixing of old steel tubing and connection in new or old position including necessary cuttings, threading, and new fittings such as bends, elbows, socket nipples, tapers, and reducers etc, complete all as specified and directed.(a) 80 mm dia bore |
| 23 | (b) All as per item No. 8.00 here-in-before but 50mm dia bore |
| 24 | (c) All as per item No. 8.00 here-in-before but 40mm dia bore |
| 25 | (d) All as per item No. 8.00 here-in-before but 25 mm dia bore |
| 26 | (e) All as per item No. 8.00 here-in-before but 20 mm dia bore |
| 27 | (f) All as per item No. 8.00 here-in-before but 15 mm dia bore |
| 28 | Supply and lay steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc, complete for the following sizes:- (a) 80 mm dia boreMake: Jindal/Prakash/Swastik Note :- Excavation and earth work will be measured and paid separately. |
| 29 | (b) All as per item No. 9.00 here-in-before but 50mm dia bore |
| 30 | (c) All as per item No. 9.00 here-in-before but 40mm dia bore |
| 31 | (d) All as per item No. 9.00 here-in-before but 25 mm dia bore |
| 32 | (e) All as per item No. 9.00 here-in-before but 20 mm dia bore |
| 33 | (f) All as per item No. 9.00 here-in-before but 15 mm dia bore |
| 34 | Taking up or down PVC pipe and connection laid in trenches or floors or fixed to walls complete with all fittings etc, complete all as specified and directed of following sizes of pipe :- (a) 160 mm outer dia (Note -Earthwork shall be measured and paid separately under respective item). |
| 35 | (b) All as per item No. 10.00 here-in-before but 90 mm outer dia. |
| 36 | (c) All as per item No. 10.00 here-in-before but 75 mm outer dia. |
| 37 | Supply and laying in replacement unplasticed PVC heavy duty pipes having capacity to experience 6 Kg pressure/Sqcm with all fitting laid in trenches, complete with solvent and taking down of unserviceable PVC pipe of the following size with all fitting (Earth work shall be measured and paid separately) :-(a) 160 mm diaMake : Supreme / Premier / Finolex |
| 38 | (b) All as per item No. 11.00 here-in-before but 90 mm dia |
| 39 | (c) All as per item No. 11.00 here-in-before but 75 mm dia |
| 40 | M&L for cutting of the CI/DI pipe in position for insert of new tee, branches such as Tees/Reducers/Tail pieces/collers/sluice valve/Air release valve etc.with suitable size of clamp of size 40 x 6 mm with nuts, bolts and washer of the following sizes, complete all as specified and directed:-(a) 200 mm bore |
| 41 | (b) All as per item No. 12.00 here-in-before but 150 mm bore |
| 42 | (c) All as per item No. 12.00 here-in-before but 100 mm bore |
| 43 | (d) All as per item No. 12.00 here-in-before but 80 mm bore |
| 44 | M&L for rubber gasket joint suitable for DI/CI pipe and fittings with size of nuts, washer & bolts etc, complete all as specified and directed for the following sizes :- (a) 200 mm bore |
| 45 | (b) All as per item No. 13.00 here-in-before but 150 mm bore |
| 46 | (c) All as per item No. 13.00 here-in-before but 100 mm bore |
| 47 | (d) All as per item No. 13.00 here-in-before but 80 mm bore |
| 48 | Material and labour for Run lead joint including jointing material for CI/DI pipe of following size/bore :- (a) 80 mm bore |
| 49 | All as per item No. 14.00 here-in-before but 100 mm bore |
| 50 | All as per item No. 14.00 here-in-before but 150 mm bore |
| 51 | All as per item No. 14.00 here-in-before but 200 mm bore |
| 52 | Material and Labour for CI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars,tail pieces,caps and plugs up to 150 mm bore confirming to IS: 1538-1993, complete all as specified and directed by Engineer - in - Charge. |
| 53 | M&L upto 200mm bore ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs, complete all as specified and directed. |
| 54 | S&F in repair of Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves. (a) 50mm bore Make : Zoloto/Seico/Jindal/Upadhaya/Venus |
| 55 | (b) All as per item No. 17.00 here-in-before but 40mm bore |
| 56 | (c) All as per item No. 17.00 here-in-before but 25mm bore |
| 57 | (d) All as per item No. 17.00 here-in-before but 20mm bore |
| 58 | (e) All as per item No. 17.00 here-in-before but 15mm bore |
| 59 | S&F in repair of bib tap PVC 15mm dia including taking out unserviceable tape of 15mm dia, complete all as specified and directed. |
| 60 | Supply, fixing, jointing and testing in repair of cast iron sluice valve class I (ISI MARKED) PN-1 type latest IS 14846-2000 flanged ends, drilled having stainless steel spindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etc, complete including taking down unserviceable sluice valve, complete all as specified and directed for following bore of CI pipe line :-(a) 200 mm dia bore |
| 61 | (b) All as per item No. 19.00 here-in-before but 150 mm dia bore |
| 62 | (c) All as per item No. 19.00 here-in-before but 100 mm dia bore |
| 63 | (d) All as per item No. 19.00 here-in-before but 80 mm dia bore |
| 64 | Dismantling old broken / damaged valve pit chamber of size 1050mm x 1050mm x 1050mm (internal dimention) complete including excavation and earth work, PCC 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in cement mortar 1:6, plastering in cement mortar 1:4 (internally) and including 3mm thick mild steel sheet cover and painting with two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 65 | All as per item No 20.00 above but size of valve chamber is 900 x 900 x 900 mm (internal) and complete all as specified and directed. |
| 66 | Supply, fixing, jointing and testing of Cast iron Non Return valve without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV and depositing to MES store yard, complete all as specified and as directed at site by the Engineer-in-Charge. (a) 150mm bore diaNote:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 67 | (b) All as per item No. 22.00 here-in-before but 100mm bore dia |
| 68 | (c) All as per item No. 22.00 here-in-before but 80mm bore dia |
| 69 | Labour only for attending day to day external water supply compliants of all nature i.e. leakage in water supply pipe lines, fittings/fixtures, over flow of overhead tank, no water supply, including noting the compliants in compliant register complete all as directed by Engineer - in - Charge.(Any material required for attending complaints shall be measured & paid separately under respectvie item hereinafter)Notes for Item No 23(i) The complaints shall be attended and the defetcs shall be rectified by a team of matric qualified having minimum 03 years experienced Plumber as applicable assisted with adequate No of helpers as directed by Engineer-in-charge.(ii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 150/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.(iii) In case , after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made.(iv) While attending the complaint of water supply/Electric supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A'. However , no extra payments shall be made for dewatering.(v) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fittings and fixtures will be measured and paid separetely under respective items of sch A.(vi) All T&P required for attending the Complaints shall be provided by the contractor. (vii) The Pipe Fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench, Chain wrench, Caulking tools, complete set of spanners and ladders etc..,as required at site.(viii) The Electrician shall always be in possession of all Electrician tools, LT Meggar,Earth tester, Multimeter, Crimping tool , insulation tape, Hand gloves etc required at site.(ix) Old retrived materials shall be the departmental property and shall be deposited in the MES stroe yard on the same day. |
| 70 | S&F in replacement of new generation,post top, energy saving,environment friendly, long life aesthetically designed with good symmetrical light distribution, spherical shape polycarbonate opal and clear diffuser with high power LEDs as light source of 35 Watt, color Temp- 5700 K & IP65 protection including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm, complete all as specified & directed.Make-Philips Cat Part No. BGP200 LED35 CW PSU GR SPD or equivalent in Havells/ Crompton /Bajaj etc. |
| 71 | S&F in replacement of new generation, LED Bollard in cylinderical shape, energy saving, environment friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LEDs as light source & IP65 protection including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm, complete all as specified & directed.Make-Philips, Cat Part No.BCP150 LED150/WW PSU 220-240V 7043 (1.0 M) or equivalent in Havells/CG/Bajaj etc. |
| 72 | S&F in replacement of 32mm dia hydrant opener made out of GI pipe 32mm dia medium grade including welding handle rod of 10mm dia and 450 mm long including taking down old unserviceable opener, complete all as specified and directed. |
| 73 | Supply and fixing in replacement of Lithium base Energy efficient integrated Solar street light of 32 watt in single FRP body duly polyurethane coating (Camouflage color), encases with monocrystalline solar PV panel of 65-67Wp,lithium battery 11.1/12.8V,33.0 AH with inbuilt BMS,IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminium reflector for better light distribution ,CRI>70, color temp 5700K-6500K Microcontroller based charge controller cum driver,automaticdimming function(First 04 hrs at full brightness & rest of the time at lower light level with PIR motion sensor), Dusk to dawn operation,suitable to working temp (-) 10C to (+) 55C ,weight not more thatn 16-18 Kg with adjustable MS clamp suitable for pole/wall mounting etc, complete as reequired.Make: AXON/HAVELLS/PHILLIPS.Protections: Short circuit, overload,Reserve polarity and battery protection.Firm should provide vital parametres Test report from NABL accredited lab and should be of made in India with CE & ROHS complaint.(Excavation & earth work shall be measured separately) |
| 74 | Supply only the following items, GI Socket Med grade ISI Marked of following sizes : -(a) 15 mm bore |
| 75 | (b) All as per item No. 28.00 here-in-before but 20 mm bore. |
| 76 | (c) All as per item No. 28.00 here-in-before but 25 mm bore. |
| 77 | (d) All as per item No. 28.00 here-in-before but 40 mm bore. |
| 78 | (e) All as per item No. 28.00 here-in-before but 50 mm bore. |
| 79 | Supply only GI Elbow Med grade ISI Marked of following sizes : -(a) 15 mm bore |
| 80 | (b) All as per item No. 28.05 here-in-before but 20 mm bore |
| 81 | (c) All as per item No. 28.05 here-in-before but 25 mm bore |
| 82 | (d) All as per item No. 28.05 here-in-before but 40 mm bore |
| 83 | (e) All as per item No. 28.05 here-in-before but 50 mm bore |
| 84 | Supply only GI Union Med grade ISI Marked of following sizes : -(a) 15 mm bore |
| 85 | (b) All as per item No. 28.10 here-in-before but 20 mm bore |
| 86 | (c) All as per item No. 28.10 here-in-before but 25 mm bore |
| 87 | (d) All as per item No. 28.10 here-in-before but 40 mm bore |
| 88 | (e) All as per item No. 28.10 here-in-before but 50 mm bore |
| 89 | Supply only GI Nipple Med grade as per requirement both end screwed ISI Marked of following sizes : -(a) 15 mm bore |
| 90 | (b) All as per item No. 28.15 here-in-before but 20 mm bore |
| 91 | (c) All as per item No. 28.15 here-in-before but 25 mm bore |
| 92 | (d) All as per item No. 28.15 here-in-before but 40 mm bore |
| 93 | (e) All as per item No. 28.15 here-in-before but 50 mm bore |
| 94 | Supply only GI Reducing Socket Med grade ISI Marked of following sizes : -(a) 25 mm x 15 mm |
| 95 | (b) All as per item No. 28.20 here-in-before but 25 mm x 20 mm |
| 96 | (c) All as per item No. 28.20 here-in-before but 50 mm x 40 mm |
| 97 | Supply only GI Tee Med grade ISI Marked of following sizes : -(a) 15mm x 15mm x 15mm |
| 98 | (b) All as per item No. 28.23 here-in-before but 20mm x 20mm x 15mm |
| 99 | (c) All as per item No. 28.23 here-in-before but 20mm x 20mm x 20mm |
| 100 | (d) All as per item No. 28.23 here-in-before but 25mm x 25mm x 15mm |
| 101 | (e) All as per item No. 28.23 here-in-before but 25mm x 25mm x 20mm |
| 102 | (f) All as per item No. 28.23 here-in-before but 25mm x 25mm x 25mm |
| 103 | (g) All as per item No. 28.23 here-in-before but 40mm x 40mm x 15mm |
| 104 | (h) All as per item No. 28.23 here-in-before but 40mm x 40mm x 20mm |
| 105 | (j) All as per item No. 28.23 here-in-before but 40mm x 40mm x 25mm |
| 106 | (k) All as per item No. 28.23 here-in-before but 40mm x 40mm x 40mm |
| 107 | (l) All as per item No. 28.23 here-in-before but 50mm x 50mm x 15mm |
| 108 | (m) All as per item No. 28.23 here-in-before but 50mm x 50mm x 20mm |
| 109 | (n) All as per item No. 28.23 here-in-before but 50mm x 50mm x 25mm |
| 110 | (o) All as per item No. 28.23 here-in-before but 50mm x 50mm x 40mm |
| 111 | (p) All as per item No. 28.23 here-in-before but 50mm x 50mm x 50mm |
| 112 | Supply only GI Solid Plug Heavy duty ISI Marked of following sizes : -(a) 15 mm bore |
| 113 | (b) All as per item No. 28.38 here-in-before but 20 mm bore |
| 114 | (c) All as per item No. 28.38 here-in-before but 25 mm bore |
| 115 | (d) All as per item No. 28.38 here-in-before but 40 mm bore |
| 116 | (e) All as per item No. 28.38 here-in-before but 50 mm bore |
| 117 | S&F in replacement unplasticised PVC heavy duty fitting having capacity to experience 6 Kg pressure/Sqcm of following sizes:- (a) Elbow 75 mm dia Make : Supreme / premier / Finolex. |
| 118 | (b) All as per item No. 29.00 here-in-before but Tee 75mm dia |
| 119 | (c) All as per item No. 29.00 here-in-before but Tee 90mm dia |
| 120 | (d) All as per item No. 29.00 here-in-before but Socket 75mm |
| 121 | (e) All as per item No. 29.00 here-in-before but Socket 90mm |
| 122 | (f) All as per item No. 29.00 here-in-before but Socket 160mm |
| 123 | (g) All as per item No. 29.00 here-in-before but Reducer 90mm x 75mm |
| 124 | (h) All as per item No. 29.00 here-in-before but Reducer 160mm x 90mm |
| 125 | (j) All as per item No. 29.00 here-in-before but Socket one side plain and one side threaded 90mm |
| 126 | (k) All as per item No. 29.00 here-in-before but Socket one side plain and one side threaded 75mm |
| 127 | (l) All as per item No. 29.00 here-in-before but Socket one side plain and one side threaded 160mm |
| 128 | Disconnecting & dismantling of damaged/unsv cable any type /make and Supply & laying in repair/replacement of cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs/ferrul both end of cable and testing, complete all as directed for following size :-(a) 6 Sqmm x 2 Core |
| 129 | All as per item No. 30.00 here-in-before but 10 sqmm X 2 core |
| 130 | All as per item No. 30.00 here-in-before but 10 Sqmm x 4 Core Please Enable Macros to View BoQ information |