| 1 | Taking out submersible pumping set of any capacity and type from bore well by disconnecting all electrical and mechanical connections including connected items of pump such as column pipes complete for development of borewell and lowering & reassembling the pump in the existing position by reconnecting after development/repelcement of column pipe cable etc including packing materials, nut bolts, securing of submerssible in column pipe by using insulated wires etc, and commissioning, complete all as specified and directed by Engr-in-Charge. |
| 2 | M&L for packing pea gravel of size 3 to 5 mm natural shape brought direct from river bank and packing around casing pipe through the peipes provided around the casing pipe to fill up the deficient quantity of pea gravelm complete all as specified and directed by Engr-in-Charge. |
| 3 | Development of tube well by means of pumping high velocity 250 to 400 psi air compressor all as specified including arrangement for equipment fitting and supply of sodium heptasulphate 20 kg all as specified for the bore wells located at various pump houses, complete all as specified and directed by Engr-in-Charge.Note : The above rates are also inclusive for arrangement of suitable dia and length of PVC/canvas pipes to drain the pumped water into the nearest drainage and to ensure water shall not be stagnated near the installation. |
| 4 | S&F in replacement of Mild Steel column pipe flanged both ends of 125/150 mm dia complete with necessary fixing arrangement such as suitable size of nuts, bolts, gasket, washer, etc complete 3 mtr long and 6 mm thick, complete all as specified and directed. Make - Jindal/ Swastik/ Tata/ Prakash. |
| 5 | All as per item No. 4.00 here-in-before but 100mm dia, complete all as specified and directed. Make - Jindal/ Swastik/ Tata/ Prakash. |
| 6 | S&F in replacement of chain pulley block with tripod arrangement of cap 3 Ton , 3 mtr with dimension 28X16X14 cm and having min weight 23 kg, complete all as specified and directed. |
| 7 | S&F in replacement of submersible mono block pump of cap -15 hp with min head 125 mtr, 415V, min RPM 2850,50Hz with motor body & pump shaft of SS, oil sealing, complete all as specified and directed by Engr-in-Charge. |
| 8 | S&F in replacement of flange to required size upto 150 mm dia complete with necessary fixing arrangement to pump/ header of pump i.e.welding, nut, bolt, washer etc complete all as specified and directed. |
| 9 | S&F in replacement of PVC insulated flat copper submersible cable heavy duty 16 Sqmm 3 core 1100 volt grade of the following size, complete all as specified and directed. Make - Havells/ Plaza/ Finolex. |
| 10 | S&F in replacement of chlorine test kit comprising of various, test tube, standard colour shades indicating the availability of residual chlorine including 100 ml orthothoduline solution, complete all specified and directed by Engr-in-Charge. |
| 11 | Supply & fixing in replacement or fabricated of SS frame glow sign boards on retrofit sheet size 1220mm x 760mm duly indicating the name of installation and logo of MES with suitable redium stencil and necessary items for fixing on roof /wall grouting/ PCC work complete all as directed by Engr-in-Charge.Note : Background colour sky blue and matter or size of stenci, complete as direction by Enger-in-Charge. |
| 12 | Supply & fixing in replacement or fabricated of SS frame glow sign boards on retrofit sheet size 1830mm x 1220mm duly indicating the name of installation, schematic diagram, timings of supply, In case of fire alongwith contect number and fire precaution order and necessary items for fixing on roof /wall grouting/ PCC work, complete all as directed by Engr-in-Charge.Note : Background colour sky blue and matter or size of stencil as direction by Enger-in-Charge. |
| 13 | Supply & fixing in replacement or fabricated of SS frame glow sign boards on retrofit sheet size 3500mm x 1220mm duly indicating the distribution diagram of water supply AF stn bamrauli and necessary items for fixing on roof /wall grouting/ PCC work, complete all as directed by Engr-in-Charge.Note : Background colour sky blue and matter or size of stencil as direction by Enger-in-Charge. |
| 14 | Supply & laying in replacement in trenches ductile iron (DI) pipe with spigot and socketed ends centrifugally cast class 'K-7' in any length laid in trenches complete all as specified and directed for the following sizes/bore of pipes (DI fittings and jointing materials shall be measured and paid separately) :-(a) 200mm bore dia. |
| 15 | (b) All as per item No. 14.00 here-in-before but 150mm bore dia. |
| 16 | (c) All as per item No. 14.00 here-in-before but 100mm bore dia |
| 17 | (d) All as per item No. 14.00 here-in-before but 80mm bore dia |
| 18 | M&L for cutting of the CI/DI pipe in position for insert of new tee, branches such as Tees/Reducers/Tail pieces/collers/sluice valve/Air release valve etc.with suitable size of clamp of size 40 x 6 mm with nuts, bolts and washer of the following sizes, complete all as specified and directed:-(a) 200 mm bore |
| 19 | (b) All as per item No. 15.00 here-in-before but 150 mm bore |
| 20 | (c) All as per item No. 15.00 here-in-before but 100 mm bore |
| 21 | (d) All as per item No. 15.00 here-in-before but 80 mm bore |
| 22 | M&L for rubber gasket joint suitable for DI/CI pipe and fittings with size of nuts, washer & bolts etc, complete all as specified and directed for the following sizes :- (a) 200 mm bore |
| 23 | (b) All as per item No. 16.00 here-in-before but 150 mm bore |
| 24 | (c) All as per item No. 16.00 here-in-before but 100 mm bore |
| 25 | (d) All as per item No. 16.00 here-in-before but 80 mm bore |
| 26 | Material and labour for Run lead joint including jointing material for CI/DI pipe of following size/bore :- (a) 80 mm bore |
| 27 | (b) All as per item No. 17.00 here-in-before but 100 mm bore |
| 28 | (c) All as per item No. 17.00 here-in-before but 150 mm bore |
| 29 | (d) All as per item No. 17.00 here-in-before but 200 mm bore |
| 30 | Material and Labour in replacement for CI fittings/specials such as Tees, bends (any type, radius and angle ) tapers any type, collars,tail pieces,caps and plugs up to 150 mm bore confirming to IS: 1538-1993, complete all as specified and directed by Engineer - in - Charge. |
| 31 | M&L in replacement upto 200mm bore ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs, complete all as specified and directed. |
| 32 | Supply and lay in replacement steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc, complete for the following sizes:- (a) 80 mm dia boreMake: Jindal/Prakash/Swastik Note :- Excavation and earth work will be measured and paid separately. |
| 33 | (b) All as per item No. 20.00 here-in-before but 50mm dia bore |
| 34 | (c) All as per item No. 20.00 here-in-before but 40mm dia bore |
| 35 | (d) All as per item No. 20.00 here-in-before but 25 mm dia bore |
| 36 | (e) All as per item No. 20.00 here-in-before but 20 mm dia bore |
| 37 | (f) All as per item No. 20.00 here-in-before but 15 mm dia bore |
| 38 | Supply, fixing, jointing and testing in repair of cast iron sluice valve class I (ISI MARKED) PN-1 type latest IS 14846-2000 flanged ends, drilled having stainless steel spindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etc complete including taking down unserviceable sluice valve, complete all as specified and directed for following bore of CI pipe line :-(a) 200 mm dia bore |
| 39 | (b) All as per item No. 21.00 here-in-before but 150 mm dia bore |
| 40 | (c) All as per item No. 21.00 here-in-before but 100 mm dia bore |
| 41 | (d) All as per item No. 21.00 here-in-before but 80 mm dia bore |
| 42 | S&F in replacement Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves :-(a) 50 mm boreMake : Zoloto/Seico/Jindal/Upadhaya/Venus |
| 43 | (b) All as per item No. 22.00 here-in-before but 40mm bore |
| 44 | (c) All as per item No. 22.00 here-in-before but 25mm bore |
| 45 | (d) All as per item No. 22.00 here-in-before but 20mm bore |
| 46 | (e) All as per item No. 22.00 here-in-before but 15mm bore |
| 47 | Testing of drinking water being collected from local source (bore well/Shallow wells/under ground sumps) and submission of detailed test report to the office of Engr-in-Charge as detailed below :-(a) Colleciton of water from different sources of water ie sump, bore wells & shallow wells in sterilized bottle(b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour taste, turbidity, PH value TDS total hardness, iron chloride, flouride and residual free chlorine and Bacteriological total E collie form organisms per 100 ml (MPN) and E Collie in 100 ml) and submitting with specific recommendaiton regarding suitability of water for drinking purpose. Note :- Rate quoted shall also deemed to be included for :-(i) Cost of sterilized bottle as required(ii) To and fro transportaiton charges for collection of samples from sources (sump/bore well/shallow wells) |
| 48 | Supply, installation and testing of flanged ends Water Meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet, nuts & bolts fixing in horizontal/inclind/vertical position, including taking out unserviceable water meter and depositing to MES Store yard, complete all as specified and directed at site by the Engineer-in-Charge. (a) 80 mm boreNote :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item. |
| 49 | (b) All as per item No. 24.00 here-in-before but 100 mm bore |
| 50 | Supplying , laying , jointing, welding & testing MS Pipe (Heavy duty class 'C') of followiing sizes laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connect out going water main CI/DI pipe line including taking down the unserviceable pipe and deopositing to MES Store yard all as directed by engineer - in - charge :- (a) 80 mm bore Note:- (i) MS Flanges and Flange joints complete with jointing materials shall be measured and paid separately. |
| 51 | (b) All as per item No. 25.00 here-in-before but 100 mm bore |
| 52 | (c) All as per item No. 25.00 here-in-before but 150 mm bore |
| 53 | Supplying and fixing in repair, MS flanges not less than 16 mm thick duly welded on ends of MS pipe. Flange sizes are as under, complete all as specified and directed by Engineer-in-charge :-(a) 80 mm bore |
| 54 | (b) All as per item No. 26.00 here-in-before but 100 mm bore |
| 55 | (c) All as per item No. 26.00 here-in-before but 150 mm bore |
| 56 | Supply and fixing in repair of pressure gauge 4\\" dial 0-14 Kgs/Cm2 rating, complete all as specified and directed by Engineer-in-Charge |
| 57 | S&F in repair of bib tap PVC 15mm dia including taking out unserviceable tape of 15mm dia, complete all as specified and directed. |
| 58 | Excavation in soft/loose soil trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out incl old U/s cable cover of any type , taking out/laying/cleaning/repairing of CI/GI pipe line, cable etc including making good to disturbed surfaces, complete all as specified and directed. |
| 59 | Returning, filling in & including spreading, levelling & well ramming in layers not exceeding 25 cm thick as in soft/loose soil, complete all as specified and directed. |
| 60 | Removal of surplus soil to a distance not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 mtr above ground level, complete all as specified and directed. |
| 61 | Supply, fixing, jointing and testing in repair of Cast iron Non Return valve without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV and depositing to MES store yard complete all as specified and as directed at site by the Engineer-in-Charge. Note:- Flanged joints, complete with jointing material shall deemed to be included in the unit rate of this item.(a) 150mm bore dia |
| 62 | (b) All as per item No. 32.00 here-in-before but 100mm bore dia |
| 63 | (c) All as per item No. 32.00 here-in-before but 80mm bore dia |
| 64 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material Please Enable Macros to View BoQ information |