| 1 | Labour for cutting/pruning of tree branches along security light pole around 2 mtr radius of security light fitting and removing from site including arrangement of T&P (i.e Axe, rope & ladder etc), complete all as specified and directed. |
| 2 | Dismantling and taking down non functional/ unserviceable /energy inefficient street /security light fittings/Post Top Lantern/ of capacity upto 250 W existing and refixing after minor repair to existing / directed location, complete all as specified and directed by Engineer-in-Charge.Note: Material shall be measured and paid searately under respective items. |
| 3 | S& F in replacement of LED drivers rated voltage 12/24 volt maximum out put power upto 90 W typical efficincy 93%, complete all as specified and directed. |
| 4 | S & F in replacement of LED drivers rated voltage 12/24 volt max out put power 100-150 W typical efficincy 93% , complete all as specified and directed. |
| 5 | Dismantling old U/S GI bracket of any size & length, complete all as specified and as directed by Engineer-in-Charge. |
| 6 | S&F in replacement of rigid PVC conduit 'medium grade' of size 15 mm bore incl fittings, ISI marked, fixing with PCC pole/ steel tubular pole/ garden lights/ Gate lights for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp , nut bolt and complete all as specified and directed. |
| 7 | Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out for laying of cable etc. complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Excavation in trenches exc 1.5 M wide but exc 1.5 M in depth for pipe line/pole, etc in soft / loose soil getting out and levelling of bottom surface to required level, complete all as specified and directed. |
| 9 | Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm, complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point, complete all as specified and as directed by Engineer-in-Charge. |
| 11 | M&L in replacement for Protection to cable with one layer of bricks laid flat abutting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ burnt-clay bricks, complete all as specified and as directed by Engineer-in-Charge. (Note: the gap between two adjustable bricks should not be exceed 10 mm ) |
| 12 | M&L for Un-washed dry tibba/local available sand as cushioning of under ground cable (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) and punned after laying, complete all as specified and as directed by Engineer-in-Charge. Note: Only punned thickness will be measured |
| 13 | M&L for cement concrete 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foudation,filling and mass concrete, complete including demolition of old PCC all as specified and directed. |
| 14 | M&L for cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal of poles/ coping including necessary formwork, fair finishing to exposed surfaces using extra cement, complete including demolition of old PCC all as specified and directed. |
| 15 | S & F of street light GI bracket of 1.2 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of flat iron 40 x 6mm including nuts bolts & washers for fixing on wall complete necessary fixing arrangements on pole, complete all as specified and directed. |
| 16 | Disconnecting & dismantling of damaged/unserviceable cable any type /make and Supply & laying in repair/replacement of cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs/ferrul both end of cable and testing complete all as directed for following size :-(a) 4 Sqmm x 2 Core |
| 17 | (b) Ditto all as per item No 16 here-in-before but, 6 Sqmm x 2 Core. |
| 18 | (c) Ditto all as per item No 16 here-in-before but, 10 sqmm X 2 core |
| 19 | Disconnecting & dismentling of damaged/unserviceable cable any type /make and and Supply & laying in repair/replacement of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs/ferrul both end of cable and testing, complete all as directed for following size : (a) 10 Sqmm x 4 Core[Note:-Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately] |
| 20 | (b) Ditto all as per item No 17 here-in-before but, 16 Sqmm x 4 Core |
| 21 | (c) Ditto all as per item No 17 here-in-before but, 25 sqmm X 4 Core |
| 22 | S & F in replacement or laying galvanised steel tubing medium grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 40mm bore, complete all as specified and as directed by Engineer-in-Charge. |
| 23 | M&L in replacement for boring under road horizontely of size 40 mm bore by trenchless technology using GI pipe for passing of cable in road/path in hard/soft/ loose soil, complete all as specified and directed. |
| 24 | S&F (in replacement) of automatic street light switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation switch operation should be based on Natural light Lux level. Required illuminance level for Switching ON is<= 30 lux and for switching OFF>=10 lux. The sensor should also have part night operation facility of min 4 hours to max 12 hours. The sensor along with suitable Power contactors, incoming-outgoing MCB's and Auto manual(Sensor By-pass) selection option should be enclosed in apole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, termite proof and FR grade SMC Junction box conforming to IP54. For three phase load of 8KW(Swadeep-02EC8kW3P) with: 3Nos contactors, 3 nos incoming MCB's & 3nos outgoingMCB's of 25-32 Amps each & circuit wiring (copper)of min 10 sqmm.Make: Nature switch:Kakatiya Energy system/Bajaj/Healer, Contactors: BCH/L&t/ SSchneider, MCB's: HAGER /Schneider /L&T (Exora/ AU series ) /C&S as approved. |
| 25 | Supplying, errecting (in replacement) and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\\" (inch) wide, complete all as specified and directed.Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. |
| 26 | Taking down (from High Mast) of single phase electric operated search light motor of capacity 2 HP , dismantling & Rewinding with existing gauge size copper wire and as existing Nos of turns of coils for maintaining existing capacity of the motor and varnishing ,drying incl re fixing & testing for proper rotation of search light fitting at watch tower, complete all as specified and directed. |
| 27 | S&F in replacement of interal LED Aviation light comprising of aluminium housing with polycorbonate enclosure including provision of three core copper cable conductor of size 2.5 Sqmm 3 core of white covering for making connection, fixing the fitting on wall including all necessary fixing accessories, complete all as directed and specified by Engr- in-Charge. |
| 28 | Supply, install in replacement, test and commissioning factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal incl Copper bus bar of 63amp-04 Nos and MCB SP 6 Amp-01 No of make sintex. |
| 29 | S&F in replacement of new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 70 watts (Surge protection of the light should be 10 KV )with suitable drivers etc and connecting with 4.0 sqmm Copper conductor PVC insulated twin core weather proof cable etc, fixing to wall / pole with and including bracket made out of GI pipe of suitable dia light grade not less than 1.5 mtr long, bent to shape, fixed to Pole/Wall in any position with flat iron clamps of size 30 x 4mm, complete all as specified and directed. Make:- Crompton / Philips/Bajaj/Havells. |
| 30 | All as per item No 24 here-in-before but 90 watt LED fittings, complete all as specified and directed. |
| 31 | All as per item No 24 here-in-before but LED flood light fittings 150 watts 230 volt complete and all assy duly prewired and pressure die cast aluminium housing,heat resistant tough glass with frame,IP 66 protection ans better optic for uniform distribution, complete all as specified and directed. Make:- Crompton / Philips/Bajaj/Havells or equivalent as approved. |
| 32 | All as per item No 24. here-in-before but LED flood light fittings 200 watts 230 volt complete and all assy duly prewired and pressure die cast aluminium housing,heat resistant tough glass with frame,IP 66 protection ans better optic for uniform distribution, complete all as specified and directed. Make:- Crompton / Philips/Bajaj/Havells or equivalent as approved. |
| 33 | S&F in replacement of new generation,post top, energy saving,environment friendly, long life aesthetically designed with good symmetrical light distribution, spherical shape polycarbonate opal and clear diffuser with high power LEDs as light source of 35 Watt, color Temp- 5700 K & IP65 protection including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm, complete all as specified & directed.(Make-Philips Cat Part No. BGP200 LED35 CW PSU GR SPD or equivalent in Havells/Crompton/Bajaj etc. |
| 34 | S&F in replacement of new generation, LED Bollard in cylinderical shape, energy saving, environment friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LEDs as light source & IP65 protection including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm, complete all as specified & directed. (Make-Philips, Cat Part No.BCP150 LED150/WW PSU 220-240V 7043 (1.0 M) or equivalent in Havells/CG/Bajaj etc. |
| 35 | Supply and fixing in replacement of Lithium base Energy efficient integrated Solar street light of 32 watt in single FRP body duly polyurethane coating (Camouflage color), encases with monocrystalline solar PV panel of 65-67Wp,lithium battery 11.1/12.8V,33.0 AH with inbuilt BMS,IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminium reflector for better light distribution ,CRI>70, color temp 5700K-6500K Microcontroller based charge controller cum driver,automaticdimming function(First 04 hrs at full brightness & rest of the time at lower light level with PIR motion sensor), Dusk to dawn operation,suitable to working temp (-) 10C to (+) 55C ,weight not more thatn 16-18 Kg with adjustable MS clamp suitable for pole/wall mounting etc, complete as reequired.Make: AXON/HAVELLS/PHILLIPS as approved.Protections: Short circuit, overload,Reserve polarity and battery protection.Firm should provide vital parametres Test report from NABL accredited lab and should be of made in India with CE & ROHS complaint.(Excavation & earth work shall be measured separately) |
| 36 | M&L for painting on steel pole upto 11 mtr initially scraping deteorated paint by emery paper and complete removal of rusted suface, painted with one coat of red oxide zinc chrome primer on exposed prepared surface and providing 03 Nos of 30 cm wide circular bands with black and yellow paint starting from bottom level at a gap of 30 cm in between 2 bands and numbering of pole with yellow paint over black painted background at the height og 02 meter from the bottom of pole with 02 cm larger Bold letter of height 2 inch wide, complete all as specified and as dirceted. |
| 37 | S & F in replacement Copper conductor 1.5 Sqmm 3 Core with PVC conduit of 20/25mm dia for connectionof street/Wall lights from junction box/ceiling Rose to fitting, complete all as specified and as dirceted. |
| 38 | S&F in replacement MCCB 04 pole 100 Amp, Thermal maganatic, breaking capacity not less than 25KA,415 volts, complete all as specified and as directed by Engineer-in-Charge. |
| 39 | S&F in replacement MCCB 04 pole 160 Amp, Thermal maganatic, breaking capacity not less than 25KA,415 volts, complete all as specified and as directed by Engineer-in-Charge. |
| 40 | Supply & fixing PVC insulation tape of width - 18 mm, thickness - 0.125 mm in length of 25 mtr, ISI marked for proper insulation of joints in wire where as required or directed. |
| 41 | S & F in replacement of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and fixed with MS clamps, bolts and nuts of approved size, for LT, 20X15 cm size, complete all as specified and directed. |
| 42 | S&F in replacement of Flexible LED strip 25W, IP 65 WW uses high brightness, transparent,Heat resistant, water proof, anti dust with PVC covering duly visible in dark from far off distance fitted with suitable connectors for inter connection along with driver complete all, plug and socket arrangement suitable to be fitted on edges of buildings, pathways and outer periphery of boundary walls Main gates, Hard standings etc complete with clamping at suitable distance to take the shape of required physical structure of Warm white/Dark blue, complete all as specified and directed. Make : Philips or its equivalent in Havells/ CG/ Bajaj or as approved. |
| 43 | M & L for making 02 Nos , holes in street light pole for cable inserting through welding /drilling of 15 mm dia, complete all as specified and directed. by Engr-in Charge. |
| 44 | M & L for inserting cables in junction box through PCC Coping Pipe with taking out existing cable around the pole incl excavation,opening of existing cable loop etc for incoming & outgoing cable, complete all as specified and directed by Engr-in-Charge. |
| 45 | M & L in replacement for single sided glow sign board of size 2mtr x1.2 mtr 40 cm made out of 25 mm MS pipe 'H' frame covered with PGI sheet 24 SWG gauge on all sides except front side, front side with flex sheet duly digital print embassing as directed by Engr-in-charge showing location/details of installations as directed and writing of letters (Block,Roman,Italic) in 2/3 row, the same letter should be printed and fixed with aluminium equal angle 25x25x3 mm thick fixed with screw and providing inside LED T/L 1x 10 Watt-04 Nos for glowing the sign boards at night with necessary internal electrical connection fixed on wall/angle by means of nuts/bolt, Angle.Item are inclusive of paint of 2 coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed. |
| 46 | Earthing in replacement of complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by Engr-in-Charge( Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5) will be measured separately under respective item. |
| 47 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material Please Enable Macros to View BoQ information |