| 1 | Surface dressing n.exc 15 cm deep and getting out in hard/dense soil complete all as specified and directed by the Engg-in-Charge. |
| 2 | M&L for Excavation in trenches n exc. 1.5m in depth for foundation and not exc 10 sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed by the Engg-in-Charge. |
| 3 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation,filling and mass concrete complete all as specified and directed by the Engg-in-Charge. |
| 4 | M&L for precast cement concrete type C1, 1:3:6 using 20mm graded stone aggregates, block masonary with solid blocks, exc 10cm width and setting in CM 1:6 complete all as specified and directed by the Engg-in-Charge. |
| 5 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; in flat rough finished surfaces of concrete complete all as specified and directed by the Engg-in-Charge. |
| 6 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions in flat fair finished surfaces of concrete complete all as specified and directed by the Engg-in-Charge. |
| 7 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc in flat rough finished surfaces of concrete complete all as specified and directed by the Engg-in-Charge. |
| 8 | M&L for TMT bars Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including for mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engg-in-Charge. |
| 9 | M&L for TMT bars Mild steel bars 5mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including for mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engg-in-Charge. |
| 10 | M&L for reinforcement cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) in foundation , including rafts, footing,foundation beams, plinth beams, bases for coloums etc.complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for reinforcement cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts, complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for reinforcement cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressumers, lintel over 1.5m span complete all as specified and directed by Engr-in-Charge. |
| 13 | Returning filling incl spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed by the Engg-in-Charge. |
| 14 | Removing excavated material n.exc. 50 m and deposited were directed at a level n.exc.1.5 m above the starting point complete all as specified and directed by the Engg-in-Charge. |
| 15 | M&L for Earth filling in floors including spreading, levelling and ramming with watering as required in layers n.exc 25cm thick complete all as specified and directed by the Engg-in-Charge. |
| 16 | M&L for Hard core of broken stones or boulders of gauge in exc 63mm but n exc 100mm deposited spread and levelled in layers n. exc 15cm thick incl watering and rolled to true surface complete all as specified and directed by the Engg-in-Charge. |
| 17 | M&L 75mm thick cement concrete (1:4:8) type D2 using 40mm graded aggregate as in sub base to floor complete all as specified and directed by the Engg-in-Charge. |
| 18 | M&L PCC 1:3:6 type C2 ( using 40mm grade aggregate) 75 mm thick as in plinth protection/paving complete all as specified and as directed |
| 19 | M&L rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finishing even and smooth without using extra cement complete all as specified and directed by the Engg-in-Charge. |
| 20 | M&L rendering 15mm thick in CM 1:4 on other fair faces of brick work or concrete surfaces in two layers 10mm & 5mm thick with WPC to be used in outer layer of 5mm thick, finishing even and smooth without using extra cement complete all as specified and directed by the Engg-in-Charge. (WPC measured and paid seperately) |
| 21 | Supply only liquid waterproofing compound complete all as specified and directed by the Engg-in-Charge. |
| 22 | M&L Fe-290 (Gde E-165) for roof trussed (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by the Engg-in-Charge. |
| 23 | S&F Rolled mild steel Gde Fe-290 (Gde E-165) as in Plates (plain or chequered) channels,angle sections, square cut or notched (ordinary & counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed by the Engg-in-Charge. |
| 24 | S&F 20mm dia of neck mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, length of bolt exc 30cm long complete all as specified. |
| 25 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge. |
| 26 | S&F for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge. |
| 27 | M&L PCC type B0 1:2:4 (12.5mm graded aggregate) 25mm thick as in floor finished surfaces fair and even to receive tile complete all as specified and directed by the Engg-in-Charge. |
| 28 | M&L Non skid Ceramic coloured tiles 7 to 8mm thick area of each tiles exc 0.06 sqm but not exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm screed bed in CM 1:6 finished even and smooth for receive tiles complete all as specified and directed by the Engg-in-Charge. |
| 29 | M&L for Glazed ceramic coloured tiles in vertical surfaces 350x450x7mm thick etc set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade of tile over 10mm thick rendering in cement mortar 1:4 in backing coat of plaster for skrting/dado complete all as specified and directed by the Engg-in-Charge. |
| 30 | S&F 2nd class softwood (KAIL) as in Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by the Engg-in-Charge. |
| 31 | S&F 35mm thick 2nd class soft wood (KAIL) plain framed panelled shutters (any No of pannels) with panels of timber flat on both sides (Feather edgeed), or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats complete all as specified and directed by the Engg-in-Charge. |
| 32 | S&F 30mm thick 2nd class soft wood (KAIL) glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc divided into squares with plain chamfered or rounded, mitred and rebated sash bars any numbers complete all as specified and directed by the Engg-in-Charge. |
| 33 | S&F 100 mm butt hinges medim weight cold rolled mild steel and fixed with screws or welded complete all as specified and directed by the Engg-in-Charge. |
| 34 | S&F butt hinges medium weight cold rolled mild steel of 75 mm long complete all as specified and directed by the Engg-in-Charge. |
| 35 | S&F anodised aluminium barrel tower bolt extruded sections 150 mm size complete all as specified and directed by the Engg-in-Charge. |
| 36 | S&F 125mm extruded aluminium alloy handles febricated type anodised complete all as specified and directed by the Engg-in-Charge. |
| 37 | S&F 100mm extruded aluminium alloy handles febricated type anodised complete all as specified and directed by the Engg-in-Charge. |
| 38 | S&F 250mm Aluminium alloy, anodised,sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by the Engg-in-Charge. |
| 39 | S&F Figured glass, pin head type and glazing with oil putty in square n exe 0.5 sqm in each pane complete all as specified and directed by the Engg-in-Charge. |
| 40 | M&L preparation of new plastered surfces of walls and applying three coat wash complete all as specified and directed by the Engg-in-Charge. |
| 41 | M&L for preparation of new plastered surfaces on walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed by the Engg-in-Charge. |
| 42 | M&L for preparation of wood and wood based material surface of any description description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by the Engg-in-Charge. |
| 43 | M&L for prepation of new or previously untreated surfaces on steel of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by the Engg-in-Charge. |
| 44 | S&F High grade stainless steel toilet pan of size 58.5x48.2x30cm (excludiig flushing cistern and flush pipe) complete all as specified and directed by the Engg-in-Charge. |
| 45 | S&F PVC flushing cistern valveless syphonic action type flushing cistern low level 10Ltrs white with inlet ball valve float and handle incl bracket complete all as specified and directed by the Engg-in-Charge. |
| 46 | S&F WHB counter sunk type ovel under/over counter shape in fixed & on stone slab incl necessary cutting etc complete all as specified and directed by the Engg-in-Charge. |
| 47 | S&F pillar tap 15mm bore fancy type cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed and fly screwed for iron pipe complete all as specified and directed by the Engg-in-Charge. |
| 48 | S&F 15mm dia chromium plated fancy type Bib tap with round handle screwed down screwed for iron pipe or brass ferrule complete all as specified and directed by the Engg-in-Charge. |
| 49 | S&F 15mm dia chromium plated fancy type stop valves/angle cock screwed down high pressure, screwed for iron pipe complete all as specified and as directed. |
| 50 | S&F PVC connection15mm size, with PTMT nuts of length 600mm complete all as specified and directed by the Engg-in-Charge. |
| 51 | S&F 32mm CP waste coupling with waste pipe complete all as specified and directed by the Engg-in-Charge. |
| 52 | S&F 600x450mm beveled edge mirror of selected quality, thickness of glass 5mm, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by the Engg-in-Charge. |
| 53 | S&F Towel rail 600mm long PTMT fixed with and incl chromium plated brass screws and wooden/ plastic cleats (Min Wt 170 gms) complete all as specified and directed by the Engg-in-Charge. |
| 54 | S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement diameter of outlet 75mm complete all as specified and directed by the Engg-in-Charge. |
| 55 | S&F 75mm bore PVC (SWR) bends any radius with access door complete all as specified and directed by the Engg-in-Charge. |
| 56 | S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed |
| 57 | S&F 110mm PVC (SWR) 'P' trap complete all as specified and directed by the Engg-in-Charge. |
| 58 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed by the Engg-in-Charge. |
| 59 | S&F 110mm bore PVC (SWR) bends any radius with access door complete all as specified and directed by the Engg-in-Charge. |
| 60 | S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed by the Engg-in-Charge. |
| 61 | S&F PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge. |
| 62 | S&F PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge. |
| 63 | S&F for 25mm outer dia 3-layer PPR polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stablized and antimivrobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors complete all as specified and directed by the Engg-in-Charge. |
| 64 | S&F for 20mm outer dia 3-layer PPR polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stablized and antimivrobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors complete all as specified and directed by the Engg-in-Charge. |
| 65 | S&F rotational moulded polytheline water storage tank 1000Ltrs capacity (cylinercial/vertical with closed top) hoisted and fixed in position complete all as specified and directed by the Engg-in-Charge. |
| 66 | S&F Angle Iron (and FI, staging for water tank and the like including caps bases splices etc built up from two or more beam or channel section angle with plate including all lattice bars stiffenes gusset plate etc (Fe-290quality A) complete all as specified and directed by the Engg-in-Charge. |
| 67 | S&F Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed of 20mm bore dia complete all as specified and directed by the Engg-in-Charge. |
| 68 | S&F anodised aluminium barrel tower bolt extruded sections 200 mm size complete all as specified and directed by the Engg-in-Charge. |
| 69 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by the Engg-in-Charge. |
| 70 | S&F Solid PVC Wall Lining consisting of 5mm thick wood grain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed by the Engg-in-Charge. |
| 71 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed by the Engg-in-Charge. |
| 72 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by the Engg-in-Charge. |
| 73 | M&L for two coats of cement based paint on old plastered surfaces of walls including preparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 74 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework complete all as specified and directed by the Engg-in-Charge. |
| 75 | M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:4, complete all as specified and directed by the Engg-in-Charge. |
| 76 | M&L for stone masonry walling of random rubble,uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed by the Engg-in-Charge. |
| 77 | Demolition of cement concrete (reinforced) of any description and in any position complete all as specified and directed by the Engg-in-Charge. |
| 78 | M&L for precast cement concrete type B-1 (1:2:4) using 20mm graded stone aggregates as in lintels, landings, coverslabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified and directed by the Engg-in-Charge. |
| 79 | Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and directed by the Engg-in-Charge. |
| 80 | Dismantling PVC water tanks of capacity exc 500 but n exc 1000 ltr and removing to store complete all as specified and directed by the Engg-in-Charge. |
| 81 | Taking down shutters exc 1sqm and n exc 2 sqm each complete all as specified and directed by the Engg-in-Charge. |
| 82 | S&F 3mm thick sheet glass ordinary quality and glazing with beading in squares n.exc 0.5 Sqm in each pane complete all as specified and directed by the Engg-in-Charge. |
| 83 | M&L for preparing old wooden surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed by the Engg-in-Charge. |
| 84 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed by the Engg-in-Charge. |
| 85 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete incl 20mm thick screed bed in CM 1:4 complete all as specified and directed by the Engg-in-Charge. |
| 86 | M&L for two coats of synthetic enamel paint on old plastered surfaces of any description over 10cm in width or girth,not otherwise described including preparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 87 | Taking down PVC pipe, eaves and gutters (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by the Engg-in-Charge. |
| 88 | S&F Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed by the Engg-in-Charge. |
| 89 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by the Engg-in-Charge. |
| 90 | M&L for providing plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in copings, benching etc. complete all as specified and directed by Engr-in-charge. |
| 91 | M&L for precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slab for manhole etc with plane faces complete all as specified and directed by Engineer-in-Charge. |
| 92 | M&L for TMT bars 6mm to 8 mm dia cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed by the Engineer-in-Charge. |
| 93 | Removing excavated material (soil) exc. 500 m but n.exc. 1.5km and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed by the Engg-in-Charge. |
| 94 | M&L for HDPE DWC pipe 200mm internal dia and external dia 230mm SN-04 confirming to SN-4 fixed with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc single Y junction laid in tranches and jointed with cement solvent including testing complete all as specified and directed by Engineer-in-Charge. |
| 95 | M&L for concrete bed to drain pipe in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 200 mm bore pipe, complete all as specified and directed by Engr-in-Charge. |
| 96 | M&L for provn of Sockage well incl excavation in hard dense soil, foundation in PCC 1:3:6 Well of honey combed and each solid in M-25 Concrete, incl, intercepting chamber, screen chamber stone work in CM 1:4 RCC cover slab in M-25 filling with stone boulder of size 3.00m dia and 3.00m deep complete all as specified and directed by the Engg-in-Charge.(As per TD Drg No. CESZ/TD/1078/2011, Sheet 1/1) |
| 97 | Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 98 | M&L for Point wiring for light/fan/bell with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point controlled by one switch. |
| 99 | All as per Srl item No. 98 here in before but for one 3 pin 5 Amps socket outlet on same board. |
| 100 | All as per Srl item No. 98 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board. |
| 101 | All as per Srl item No. 98 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board. |
| 102 | S&F Switch piano flush type 5 Amps, single pole one way. |
| 103 | S&F Switch socket combination 2 in 1, 5 and 15 Amps flush type. |
| 104 | M&L for ceiling rose on PVC square blocks surface bakelite 3 terminal complete all as specified and directed by the Engg-in-Charge. |
| 105 | S&F LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by the Engg-in-Charge. |
| 106 | S&F LED lights fitting, surface mounting general purpose ultra slim economical LED batten of 1x18W, lumen out put 100lm/wattt, CCT:6500K/3000K, PF>0.9, in extruded PC housing and round/square shaped diffuser including connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by the Engg-in-Charge. |
| 107 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm including making arrangement for fixing complete all as specified and directed by the Engg-in-Charge. |
| 108 | S&F Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 8way with 200Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge. |
| 109 | S&F 240V, 10KA C curve MCB SPN 32Amp in the existing MCB DB complete with connection testing complete all as specified and directed by the Engg-in-Charge. |
| 110 | S&F 240V 10KA C curve MCB SP 5 to 32Amp in the existing MCB DB complete with connection testing complete all as specified and directed by the Engg-in-Charge. |
| 111 | S&F LED flood light 70watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete all as specified and directed by the Engg-in-Charge. |
| 112 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground vertically (earth pit not less than 2.25metres deep below ground level) with top edge of the plate not less than 1.5metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and connected to main switch board or equipment, including watering arrangement with GI medium grade 20mm bore watering pipe with funnel and wire mesh with PCC chamber CI cover with frame including 15mm dia GI pipe light grade for protection of earthing lead etc including necessary excavation in any type of strata, returning, filling, removal of soil outside MD land, filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to earthing test point all as specified or indicated including testing on completion.Notes:- (i) Earth continuity conductor including protection pipe upto 7.5 meters from earth electrode will be include in unit rate,(ii) Arrangement for earth resistance test should be carried out by the contractor. No extra payment shall be provided for the same. |
| 113 | S&F 1100volts grade heavy duty 16Sqmm 2core flat cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by the Engg-in-Charge. |
| 114 | S&F Switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps flush type complete all as specified and directed by the Engg-in-Charge. |
| 115 | S&F Socket Outlet 2 in 1, 5Amp flush type complete all as specified and directed by the Engg-in-Charge. |
| 116 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 12 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge. |
| 117 | S&F in replacement 240V 10KA C curve MCB SPN 40 to 63Amp in the existing MCB DB complete with connection testing complete all as specified and directed by the Engg-in-Charge. |
| 118 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 16way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge. |
| 119 | Cutting existing steel tubing for alterations or additions complete all as specified and directed by the Engg-in-Charge. |
| 120 | Note : Deduction for amount of Rs. 23,716.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract. Please Enable Macros to View BoQ information |