| 1 | Taking down chowkhats of frames exc 1.50 sqm but n. exc 4.0 sqm with shutters (without taking off shutters from the frames) all as spd. |
| 2 | Taking down chowkhats or frames n.exc 1.50 sqm with shutters (without taking off shutters from the frames) all as spd. |
| 3 | Taking down shutters of any description exc 1 Sqm and n exc 2 Sqm each complete all as specified. |
| 4 | S & F 2nd class hard wood plain solid straight chowkats and frame of wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 5 | S&F mild steel work, Grade Fe-410-0 or Fe- 310-0, as in flat iron (for holdfast) complete all as specified and as directed. |
| 6 | S & F for glazed and Skelton shutters 30mm thick of 2nd class hardwood,open rebated and prepared to receive glass, guaze etc (Without Sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc;sizes of members of shutters as specified in SSR Part I 2009, Section 8, clause 8.24 (a); suppplied and fitted to chowkats complete all as specified and as directed. |
| 7 | S&F 30 mm thick second class hard wood Glazed and skeleton shutters for window and ventilators etc, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (b) complete all as specified and as directed. |
| 8 | S&F for 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panel only) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated fitted to chowkats all as specified and directed |
| 9 | S & F 2nd class hard wood Plain, framed,panelled shutters 30mm thick(any number of panels), with panels of timber flat on both sides(feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats as specified. |
| 10 | S&F for 2nd class hard wood 35mm thick glazed and skeleton door shutters factory made, open rebated and prepared to receive glass or gauge etc with rounded, chamfered or mitred sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge, size of stiles rails and other parts as per clause 8.24 (a) of SSR Part-I 2009 (Larger size to be provided) complete all as specified and directed |
| 11 | M&L 3 mm thick plain glass sheets ordinary quality in squares n exc 0.5sqm each pane fixed with aluminium frame work etc all as specified and directed. |
| 12 | S & F for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless steel wire staples all as specified & directed. |
| 13 | S & F 75mm size mild steel butt hinges medium weight cold rolled and fixed. |
| 14 | S&F for 100 mm long Butt hinges, medium weight, cold rolled mild steel, and fixed |
| 15 | S&F for 300 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts all as specified. |
| 16 | S&F for aluminium anodized barrel tower bolts 100 mm of extruded section and fixed complete all as specified and directed. |
| 17 | S&F for aluminium anodized barrel tower bolts 150 mm of extruded section and fixed complete all as specified and directed. |
| 18 | S & F 100mm size extruded aluminium alloy handles, fabricated type anodised |
| 19 | S & F 150mm size extruded aluminium alloy handles, fabricated type anodised |
| 20 | S&F pre coated mild steel floor door stopper ,tongue anodized 140mm length including vulcanised rubber piece |
| 21 | S & F GI steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm etc all as specified. |
| 22 | S&F PVC coated 25mm dia mild steel chromium plated curtain rod of medium weight and including fixing brackets, finials and decorative end supports etc complete all as directed” |
| 23 | S&F in repair 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed (Helical door closer). |
| 24 | M&L for preparation of new steel surfaces / MS sheet of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer all as specified and directed. |
| 25 | M&L for preparation of old steel surfaces / MS sheet of any description over 10 cm width or girth and applying two coats of synthetic enameled paint all as specified and directed. |
| 26 | Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 27 | Dismantling timber scantlings framed work 40 sq. cm and over in section, in any position |
| 28 | S&F for Second class hard-wood clean sawn timber framed & fixed in scantlings fixed with nails in any situation. |
| 29 | M&L in repair second class hard-wood plain fillets exc 13 and n exc 25 sq cm square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and as directed. |
| 30 | M & L preparation of new wood/plywood or wood / plywood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 31 | M & L preparation of Old wood/plywood or wood / plywood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified complete all as specified and as directed. |
| 32 | Dismantling structural steel work in cluding doors, gates but excluding framed truss etc. |
| 33 | Excavation and trenches n. exc 1.5 m wide and n.exc 1.5m in depth for foundation of manhole, as in any type of soil complete all as specified and as directed. |
| 34 | M & L for PCC 1:3:6 type D-2 (using 40mm graded stone aggregate) as in foundation filling or mass concrete complete all as specified and directed. |
| 35 | S & F in mild steel work conforming to Fe 290 Gde-E-165 in posts, wall & struts angle including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets ( for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified & directed. |
| 36 | S&F for Fe 410 W (Gde-E-250 quality A) roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 37 | Dismantling to plain or corrugated MS sheet any gauge, thickness including nainital or similar pattern as in roof covering complete all as specified and directed. |
| 38 | S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws etc complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs / Hangers for scaffolding as all arrangement.) |
| 39 | S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in valley gutter, ridge hips etc. fixed with self tapping screws etc complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs / Hangers for scaffolding as all arrangement.) |
| 40 | Supply and Fix 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screws and washers, in roofs, walls etc. with grade of zinc coating 275 gsm complete all as specified and as directed. |
| 41 | Returning filling in including spreading, levelling,watering and well ramming in layers not exceeding 25cm thick. |
| 42 | Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding and depositing where directed at a level not exceeding 1.5m above the starting point and disposal. |
| 43 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15cm thickness (below or above ground level) all as directed. |
| 44 | M&L for 40 mm thick PCC 1:2:4, type B-1 ( 20 mm graded aggregate) in flooring finshed even and smooth without using extra cement complete all as specified and directed. |
| 45 | S&F for non skid coloured Ceramic tiles 07-08 mm thick (square/ rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 46 | M&L for 75 mm thk PCC 1:4:8 type D-2 as in subbase to flooring complete all as specified and as diretcted. |
| 47 | M&L for 100 mm thk PCC 1:4:8 type D-2 as in subbase to flooring complete all as specified and as diretcted. |
| 48 | M&L for 25 mm thick Cement concrete type B-1,1:2:4 (20mm graded aggregate) as in subbase to flooring complete all as specified and as diretcted. |
| 49 | M&L for cement concrete type C-2, 1:3:6 (using 40mm graded agg) as in plinth protection and paving 75mm thick laid in slope finished even and fair without using extra cement incl making joints every 2.5m and corner filled with bitumen 85/25 complete all as specified. |
| 50 | M&L for 15 mm thick screed bed in CM 1:6 for laying floor tiles complete all as specified. |
| 51 | M&L for 20 mm thick screed bed in CM 1:6 for laying floor tiles complete all as specified. |
| 52 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 53 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete in floor as specified and directed. |
| 54 | M&L for chequered cement concrete tiles 20cmx20cmx25mm thick set with grey cemnt and no pigment, jointed and pointed in neat cement slurry in floor as specified and directed. |
| 55 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded & pointed in any mortar as specified. |
| 56 | M&L for Granite 25mm thick (of any type) work(table rubbed and polished)in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite as specified and directed. |
| 57 | Demolition of brick work/ boulder masonry built in cement mortar or cement lime mortar including all quions, arches, pillars, etc complete all as specified and directed. |
| 58 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete all as specified and directed |
| 59 | M&L Rendering 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) in two layers (5mm finishing layer over 10mm base layer) finished even and smooth without using extra cement complete all as specified and directed |
| 60 | M&L rendering 15 mm thick in CM 1:4 on concrete surfaces finished even and smooth without using extra cement . |
| 61 | M&L for newly plastered surfaces of walls and applying two coats of cement based paint, over a coat of primer complete all as specified and directed. |
| 62 | M&L PCC 1:3:6 type C-1 (using 20mm graded aggr) as in surface channels & drains,benching of manholes complete allas spd and directed. |
| 63 | M&L Extra for forming fair finished drain or channel 30cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/stop ends etc complete all as specified and as directed. |
| 64 | M&L for chequered cement concrete tile 30cmX30cmX 20 to 25mm thick set jointed and pointed in neat cement siurry in floor with grey cement and pig ments over and including 20mm thick screed bed or bedding layer of CM (1:6) complete all as specified and as directed. |
| 65 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets |
| 66 | M&L for Plywood 9mm, grade BWR,type BB, fixed with screws to timber frame work fixed in repair complete all as specified and as directed. |
| 67 | S&F 4 mm thick ply wood, grade BWR, type BB, fixed with nails to timber frame work on wall surfaces. |
| 68 | S&F 6 mm thick ply wood, grade BWR, type BB, fixed with nails to timber frame work on wall surfaces. |
| 69 | Supply and fix 600mmx600mmx4mm thick ‘E’ Board Classic (Make-Everest industries Ltd) as in false ceiling including supply and fixing GI ‘Tee” grid frame work made of special section of M.S galvanized sheet 0.30mm thick , bottom portion painted with cellular nitro painting, warping the suspending wire around the existing wooden/steel purlin /rafter for suspending grid frame work of size 605mmx605mm suspended with 4 mm dia GI wire @ 1200mm c/c on main Tee and fixed to T-grid with the help of level clip or as per manufacturer direction. The section consisting of main Tee 37mmx24mmx0.60mm, cross runner tee 37mmx24mmx0.60mm and perimeter angle of 24mmx24mmx0.50mm thick. Perimeter angle to be fixed to wall with GI screw of 40mm long @ 450 mm c/c along the perimeter of wall including applying two coats of distemper oil emulsion complete all as specified and directed |
| 70 | Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 71 | All as per item No. 70 here in before One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5sq. mm size |
| 72 | All as per item No. 70 here in before but for one 3 pin socket outlet 5 Amps three pin controlled by one switch on independent board complete all as specified directed. |
| 73 | All as per item No. 70 here in before but for one 5 pin socket outlet 15 Amp and 5 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire with terminal box of size 175mm x 100mm x 3.15mm complete all as specified. |
| 74 | S&F Socket outlet 2 in 1, 3 pin, 5 amp flush type |
| 75 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type |
| 76 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 15 Amp, 240 Volts complete all as specified & directed. |
| 77 | Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed. |
| 78 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed. |
| 79 | Supply and fixing lamp holder, insuleted body with pack plate suitable batten fitting on wall duly grouted/fixed in solid block wall or on wooden board complete all as specified and directed. |
| 80 | S&F LED lamp 10 Watt, CDL, B-22 cap, (Pin type), 230W, PF not less tha 0.85 (min). |
| 81 | Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 82 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, (warm/white), 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete |
| 83 | S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 45 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbersclmaps, all fixing arrangements such as fastners, bilts, nuts washers etc all as specified and directed. |
| 84 | S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including GI brackets with fixing arrangements & connected items, twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site all as specified and directed. |
| 85 | S&F LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connenting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 hz complete all as spicified and directed. |
| 86 | Supply and fix exhaust fan,steel body AC single phase, 230V of size 450mm sweep heavy duty with blades, and frame and louvers complete all as specifed and directed. |
| 87 | S & F exhaust fan sweep 300 mm voltage 230 V 50 Hz 1200 RPM noiseless metal body light-weight rust proof body self closing louvers and blades complete all as specified and as directed. |
| 88 | Supply and fixing, metal clad socket out let with MCB single pole 20 Amp, 240 V including sheet metal enclosure complete fixed on flat iron 32x6 mm or 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified. |
| 89 | Supply and fix electric water heater(Geyser), storage type steel body with copper inner tank and heating element up to 2 KW capacity 50 litre, BEE 5 star rated adjustable temprature setting 0-90 degree C complete with accessories such as safety wall, thermostate, NRV indication lamps, inlet outlet connections,air vent connections, connection pieces including all fixing arrangements such as fastners, bilts, nuts washers etc including making good disturbed wall surfaces matching with the existing surface and finishing complete all as specified and directed by Engr in charge. |
| 90 | S & F incl leakage testing galvanised steel water tubing medium grade 15 mm dia bore with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches all as specified & directed. |
| 91 | S&F Stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of size 15 mm complete all as specified and directed |
| 92 | S&F Bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified & as directed by engr-in-charge. |
| 93 | M & L for PVC connections 15mm size with PTMT nuts of length 450mm for hot and cold water connection complete all as specified and directed |
| 94 | Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 12 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board complete all as specified and directed |
| 95 | Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 8 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board complete all as specified and directed |
| 96 | S&F MCB SPN having braking capacity 10KA, 32 Amps, 240 V complete all as specified and directed. |
| 97 | S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 240 V complete all as specified and directed. |
| 98 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 99 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 25 Sqmm 4 core complete all as specified and directed. |
| 100 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 16 Sqmm 4 core complete all as specified and directed. |
| 101 | Supplying, laying, jointing & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 35 sqmm 4 core as per IS 7098 Pt-II laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as directed and specified. |
| 102 | Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc) |
| 103 | Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC. |
| 104 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out complete all as specified and as directed. |
| 105 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning. |
| 106 | Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flat ie length of cable cover shall be laid across the cable, complete casted with PCC 1:2:4 Type B1 using 20mm graded crushed stone aggregateall as specified and directed |
| 107 | S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed cable with multistranded copper conductor 6 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipe along with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 4 sqmm earth wire and 2 Run of 6 sqmm cable shall be measured as one run.) |
| 108 | Supply and laying galvanised tube light grade ISI marked of size 50 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed. Please Enable Macros to View BoQ information |