| 1 | PUMP CHAMBER Construction of Pump Chamber size 3.05mX3.70m with W.C, with gravel pit & electric wiring as per DWSS standard design & analysis, complete in all respects. |
| 2 | PUMPING MACHINERY |
| 3 | Providing & Installing Testing & Commissioning of one No. Electrically driven Submersible Pumping set of reputed make capable of delivering 620 LPM against a head of 82 mtr along-with electric panel board consisting of electric appliance such as automatic Starter, Main Switch. Volt Meter, Ampere Meter, ELCB, Shunt Capacitor, Single Phase Preventer, Indicating Lamps, MVB/MCCBs etc. including G.I. Column Pipe of suitable size 54 m (in 3 m Lengths each with flanges, screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable (of reputed make) complete in all respects. As per ISI 1239-2004 |
| 4 | Rate of Motor with Pump |
| 5 | Panel Board |
| 6 | Submersible cable Size 6.00mm2 |
| 7 | Column Pipe (G.I) 100 mm i/d |
| 8 | SOLAR PANEL ENERGY SYSTEM |
| 9 | Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects. |
| 10 | C.I.FITTING INSIDE PUMP CHAMBER |
| 11 | Providing & Installing 150 mm dia delivery main (from Tube-well to duck foot bend including cost of C.I.D/F Pipes, D/F Sluice Valves, D/F Non Return Valve & Specials as C.I. Bends, Tail Piece Tees, Pressure gauge, Air Valve,,V notch haudi etc. inside the Pump chamber as per DWSS standard design and analysis complete in all respects. (Annexure-3) As per IS1536-2001 & 1538-1993 reaffirmed 1999. |
| 12 | Disinfection Unit: |
| 13 | Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 leter of bleaching powder solution/ sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter. |
| 14 | RCC OHSR |
| 15 | Constructing of 1 No. RCC OHSR of 100KL Capacity having staging Height 20.50 mtr. & FSL 24 mtr from formation level complete with external RCC Stair case with landing slabs at each staging RCC roof, ventilator single manhole cover lightning conductor etc. complete as described in schedule No.3 providing and fixing CI/ DI K9 D/F expansion Joints, bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing Duck foot bends, Conforming IS-9523 with latest amendments) and D1 19 D/F sluice Valve duty ISI marked (IS 14846-2000 Or latest on each with inlet outlet and scour pipes. Including Providing and Installing inlet outlet scour pipe and overflow DI K-9 double flanged pressure pipes centrifugally cast as per IS 8329-2000 with latest amendment duly ISI marked from bottom dome to duck foot Bond and further up to 2.75 mtr. As per detail specification TMT steel & painting of all complete shall he included in cost & P/F aluminum ladder inside/steel ladder outside tank of the OHSR including testing of soil bearing capacity tested from the reputated institute such as PEC Chandigarh / TTT Sector-26, Chandigarh GNEC/Ludhiana/Thapar Institute of Engineer and Technology Patiala Complete in all respect SBC shall be tested in the presence of Engineer or his representative as per specifications. (The specifications & drawing are based on safe bearing capacity of Soil is not less than 8.75 tons per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per sqm. The contractor shall summit his own design keeping in view seismic Zone-IV for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard, drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Premium including overflow houdi, including providing and fixing water Level indicating system and construction of plinth protection around OHSR with masonry toe wall with including foundation depth, earthing cc 1:8:16 with 40mm stone aggregate and conglomerate floor 40mm with CC 1:24 as per DWCC specification. Providing & applying, integral crystalling slurry of hydrophilic in nature for water proofing management for vertical and horizontal surface and swellable type water stop tape. |
| 16 | C.I RISING MAIN |
| 17 | Providing, Stringing out, cutting, jointing and testing of ISI marked C.I Pipes Class-LA per IS:1536 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted including cost of excavation complete including all cartage |
| 18 | 150mm i/d (C.I Pipe) |
| 19 | Sluice Valve & Sluice Valve Chambers |
| 20 | Providing & fixing C.I D/F Sluice Valves ISI marked 14846-2000, including cost of tail piece, rubber joint, gland dori, Nuts, bolts & accessories, complete in all respects |
| 21 | 150 mm Nominal Bore (N.B.) |
| 22 | Construction of brick masonry sluice valve chamber size 0.90m x 0.90m complete in all respect |
| 23 | DEVELOPMENT OF WATER WORKS SITE. |
| 24 | Providing & fixing 1.2mtr high fencing around the head works site with 1.65 meter post, placed every 2.5 meters apart, embedded in cement concrete blocks and every tenth post to be strutted with three rows of G.I. Barbed wire weighing 9.34 Kg per 100 meters (minimum) and fixing with GI staples tied to 6mm bar nib, with binding wire or by providing cut, including drilling holes in the post, including cost of posts, winding wire, strutted earth work in the post & aluminum painting complete in all respects |
| 25 | Providing & Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4mm dia fencing pole size at bottom 4\\"x4\\", size top 3\\" x 4\\", Length 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. |
| 26 | Providing & fixing D-Hook complete with MS Bolts size 300mm x 18mm complete in all respect. |
| 27 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects. |
| 28 | Construction of masonry gate pillar including cost of MS Steel Gate size 1.22 m x 1.37 m as per DWSS standard Drawing and analysis. |
| 29 | Construction of Foot Path with masonry toe wall & earth filling and Cement Concrete 1:8:16 with 40 mm gauge stone aggregate, 40 mm thick cement concrete topping 1:2:4, inside water works as per DWSS standard Drawing and analysis. |
| 30 | Providing & fixing MS sign Board as per DWSS standard design and analysis. |
| 31 | Providing, laying, jointing, fixing & testing of GI Pipe and specials Class-B including cost of material, complete in all respects including all taxes as per DWSS approved |
| 32 | Excavation with JCB |
| 33 | GI Pipe 25mm i/d (JCB excavation) (40% Gravel) |
| 34 | GI Pipe 32mm i/d (JCB excavation) (40% Gravel) |
| 35 | GI Pipe 40mm i/d (JCB excavation) (40% Gravel) |
| 36 | GI Pipe 50mm i/d (JCB excavation) (40% Gravel) |
| 37 | GI Pipe 65mm i/d (JCB excavation) (40% Gravel) |
| 38 | Excavation with Manually |
| 39 | GI Pipe 25mm i/d (Manual excavation) (40% Gravel) |
| 40 | GI Pipe 32mm i/d (Manual excavation) (40% Gravel) |
| 41 | GI Pipe 40mm i/d (Manual excavation) (40% Gravel) |
| 42 | GI Pipe 50mm i/d (Manual excavation) (40% Gravel) |
| 43 | GI Pipe 65mm i/d (Manual excavation) (40% Gravel) |
| 44 | Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring. (CSR-28.7 B (A) |
| 45 | Excavation with Manually |
| 46 | DI Pipe 100mm i/d (Manual excavation) (40% Gravel) |
| 47 | Excavation with JCB |
| 48 | DI Pipe 150mm i/d (JCB excavation) (40% Gravel) |
| 49 | Making Connection with existing pipe line including cutting cost of D-Joint, labour for fixing specials excavation bailing out etc. |
| 50 | GI Pipe 25mm i/d |
| 51 | GI Pipe 32mm i/d |
| 52 | GI Pipe 40mm i/d |
| 53 | GI Pipe 50mm i/d |
| 54 | GI Pipe 65mm i/d |
| 55 | DI Pipe 100mm i/d |
| 56 | DI Pipe 150mm i/d |
| 57 | Providing & fixing C.I D/F S.V. including cost of tail piece, rubber insertion, gland dori, Nut bolts & accessories complete in all respects. ISI marked |
| 58 | 150mm i/d |
| 59 | 100mm i/d |
| 60 | Providing, fixing and jointing ISI marked Gun-Metal peet valves (Heavy Pattern) as per IS 778 with had wheels, on G.I Pipe lines laid in the ground or inside buildings including all carriage complete. |
| 61 | 25 mm i/d Gun metal peet valve heavy pattern |
| 62 | 32 mm i/d Gun metal peet valve heavy pattern |
| 63 | 40 mm i/d Gun metal peet valve heavy pattern |
| 64 | 50 mm i/d Gun metal peet valve heavy pattern |
| 65 | 65 mm i/d Gun metal peet valve heavy pattern |
| 66 | Construction of masonry sluice valve chamber size 0.60m x 0.60m complete in all respect. |
| 67 | Construction of masonry sluice valve chamber size 0.90m x 0.90m complete in all respect. |
| 68 | Provision of Rectifying the Leakage of existing Pipe Line |
| 69 | GI Pipe 25mm i/d |
| 70 | GI Pipe 40mm i/d |
| 71 | GI Pipe 50mm i/d |
| 72 | GI Pipe 80mm i/d |
| 73 | GI Pipe 100mm i/d |
| 74 | GI Pipe 150mm i/d |
| 75 | Dismantling and restoration brick paving complete in all respect |
| 76 | G.I Pipe 25mm i/d |
| 77 | G.I Pipe 32mm i/d |
| 78 | G.I Pipe 65mm i/d |
| 79 | Contractor shall be quote rates only for dismantling of mettaled road & back filling with excavated earth fully compacted the restoration of the mettaled road to its original condition will be done by the concerned department i.e. PWD (B&R) PMB/Panchayati Raj) |
| 80 | 90mm o/d 50 No road cut x 4 mtr = 200 mtr |
| 81 | Dismantling and restoration of Cement Concrete Road complete in all respect |
| 82 | 25mm i/d |
| 83 | 32mm i/d |
| 84 | 40mm i/d |
| 85 | 50mm i/d |
| 86 | 100mm i/d |
| 87 | Dismantling and restoration of Cement Concrete Road & Only Dismentling of Brick Paving complete in all respect |
| 88 | 25mm i/d |
| 89 | 40mm i/d |
| 90 | Dismantling and restoration of Interlock Tile & Only Dismentling of Brick Paving complete in all respect |
| 91 | 25mm i/d |
| 92 | 32mm i/d |
| 93 | 40mm i/d |
| 94 | 65mm i/d |
| 95 | Dismantling and restoration of Interlock Tile & Only Dismentling of Cement Concrete complete in all respect |
| 96 | 25mm i/d |
| 97 | 32mm i/d |
| 98 | Dismantling and restoration of Interlock Tile complete in all respect |
| 99 | 25mm i/d |
| 100 | 32mm i/d |
| 101 | 50mm i/d |
| 102 | House water connection |
| 103 | Providing Proposed water connection to house hold up to wall with providing laying, jointing, testing MDPE pipe line 15mm o/d (Below ground level) & GI 15mm i/d (Above ground level) Including cost of specials such as tees, bends, sockets, elbow etc, cutting threading and testing in trenches in the ground and ISI marked 15mm i/d GN ferrule as per IS:2692 and 3\\" i/d clamp with C.I bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make complete with excavation. |
| 104 | House Hold Connection for Replaced pipe so as to ensure equal distribution of water to all households. |
| 105 | Water MeterProviding fixing & jointing water meter (Multi jet) in G.I Pipe including cutting and threading pipe and making long screw etc inc. cost of G.I jam nut complete (15mm) P/F gun metal peet valves (Heavy Pattern) with hand wheel complete in all respect.Note:- The Contractor will ensure that the water meters will be procured only from those manufacture's who has obtained manufacture's licence from legal Metrology Dept, Punja. Further, the contractor has to submit a certificate regarding inspection of water makes as per provising of Legal metrology act, 2009 prior to their installation and ensure compliance to the provisions of Legal Metrology Act. |
| 106 | Bulk MeterProviding & Installing of Bulk Meter inside water works including rubber jain, Nut Bolts, Cutting and threading, piece for fixing Bulk Meter including carriage complete in all respects (ISI Make) Size 100 mm i/d |
| 107 | Environmental Management Charges |
| 108 | Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil. |
| 109 | Digging of pits in all kinds of soil &refilling the same , with the excavated earth mixed with well decayed farm yard manure @30% of pit volume and insecticide for termite control. |
| 110 | Supplying and planting permanent trees in prepared pits and watering |
| 111 | Planting seasonal flower in bedsPlanting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row |
| 112 | Painting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row |
| 113 | Providing for one way stand post with Khura complete in all respects. Please Enable Macros to View BoQ information |