Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Structural Work and Flooring |
| 2 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 3 | 15.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below |
| 4 | 50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 5 | 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 6 | 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 7 | 16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 8 | 2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock |
| 9 | 50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc. |
| 10 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 11 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 14 | 100.98.1013:Engaging Mason ( brick layer) Ist class. |
| 15 | 100.98.1008:Engaging Coolie. |
| 16 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 17 | 13.83.1:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.One coat |
| 18 | Aluminium works- Doors and Windows |
| 19 | 21.17:Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ). |
| 20 | 21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 21 | 21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 22 | 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 23 | 21.8.1:Filling the gap in between aluminium frame & adjacent RCC/ Brick / Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawing and direction of Engineer-in -Charge complete.Upto 5 mm depth and 5 mm width |
| 24 | 9.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm |
| 25 | 9.118.3:Providing and fixing to existing door frames25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm x 25 mm or less as per requirement with and average wall thickness of 1 mm ( ± 0.3 mm). PVC foam end cap of size 23x10 mm area provided on both vertical edges to ensure the overall thickness of 25 mm. An M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end -cap of the size 25 mm x 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer,s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. |
| 26 | 26.86.1:Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 45 x 70 mm |
| 27 | 26.86.3:Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 50 x 100 mm |
| 28 | 26.89.1: Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) 18 mm thick |
| 29 | 9.82:Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 30 | 9.70.1:Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete:125x64x1.90 mm |
| 31 | 9.97.1:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm |
| 32 | 9.88:Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 33 | Plumbing and Sanitary Works |
| 34 | 17.7.8:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers |
| 35 | 18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 36 | 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid |
| 37 | 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 38 | 50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 39 | 50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 40 | 18.50.1:Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 41 | OD111587/2025-2026:Providing and fixing 15mm PVC tap |
| 42 | 17.29:Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 43 | 50.18.8.2.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2 |
| 44 | 50.18.8.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2 |
| 45 | 50.18.8.5.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 |
| 46 | 50.18.8.7.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc 63 mm pipe 4 kgf/ cm2 |
| 47 | 50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 |
| 48 | 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 49 | OD115158/2025-2026:Supply and installation of submersible pump set working in single-phase/three phase, suitable for vertical installation in open wells, borewells, or sumps, and shall operate efficiently under submerged conditions. The pump set shall be capable of delivering a discharge of not less than 30 to 50 litres per minute with a total head up 30 metres, depending on site conditions. The pump shall be equipped with a water-cooled, copper-wound motor with built-in thermal overload protection. The pump construction shall include a corrosion-resistant stainless steel or cast iron body, non-return valve, and durable impellers made of thermoplastic or metal as per IS standards.The pump shall be suitable for connection with a 1\\" to 1.25\\" delivery pipe and shall include all necessary accessories for complete installation and operation. The unit must conform to relevant IS specifications, and the bidder shall provide product catalogues, test certificates, warranty details ,and manufacturer’s compliance certificate. The pump set shall be suitable for domestic water supply, overhead tank filling, including cost of pumpset, starter, cable and HDPE delivery pipe up to 15 mtr. as per the site condition |
| 50 | Electrification |
| 51 | OD111220/2025-2026:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B (Data from DAR E&M 1.10.2) |
| 52 | OD111353/2025-2026:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) (Data from DAR E&M 1.27.2) |
| 53 | OD111352/2025-2026:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) (Data from DAR E&M 1.27.3) |
| 54 | OD111351/2025-2026:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) (Data from DAR E&M 1.27.4) |
| 55 | OD111350/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet (Data from DAR E&M 1.24.4) |
| 56 | OD111349/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch (Data from DAR E&M 1.24.1) |
| 57 | OD111348/2025-2026:1 or 2 Module (75mmX75mm) Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. (Data from DAR E&M 1.27.1) |
| 58 | OD111347/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asvrequired.15/16 amp switch (Data from DAR E&M 1.24.3) |
| 59 | OD111346/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet (Data from DAR E&M 1.24.5) |
| 60 | OD111345/2025-2026:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Data from DAR E&M 1.25) |
| 61 | OD111344/2025-2026:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm (Data from DAR E&M 1.21.1) |
| 62 | OD111343/2025-2026:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm (Data from DAR E&M 1.21.2) |
| 63 | OD111342/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq.mm (Data from DAR E&M 1.17.12) |
| 64 | OD111341/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq.mm (Data from DAR E&M 1.17.21) |
| 65 | OD111340/2025-2026:Single pole Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Data from DAR ELE 2.10.1) |
| 66 | OD111339/2025-2026:40 amps Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Data from DAR E&M 2.12.1) |
| 67 | OD111338/2025-2026:63 amps Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.. (Data from DAR E&M 2.13.2) |
| 68 | OD111337/2025-2026:63 amps Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Data from DAR E&M 2.15.3) |
| 69 | OD111336/2025-2026:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. (Data from DAR E&M 2.1.2) |
| 70 | OD111335/2025-2026:Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4+36), Double door (Data from DAR E&M 2.5.3) |
| 71 | OD111334/2025-2026:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(Data from DAR E&M 5.4) |
| 72 | OD111333/2025-2026:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/coke and salt) as required. (Data from DAR E&M 5.1) |
| 73 | OD111332/2025-2026:3.15 mm copper conductor ( 10 SWG) Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. (Data from ELE 90.16.1.3) |
| 74 | OD111331/2025-2026:1200 mm 1X20W LED Lamp with box type fixture Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required. (Data from ELE 90.3.24.3) |
| 75 | OD118475/2025-2026:Supplying and fixing 20-Watt LED light fitting, energy-efficient and long-lasting, suitable for decorative applications. The luminaire shall operate on 240 Volts AC supply and produce cool white light with a luminous efficacy conforming to BIS/IEC standards. The fitting shall be compact in design with a body length of approximately 120 mm and constructed using high-grade thermoplastic or aluminium housing with adequate heat dissipation. The LED chip shall have a minimum rated life of 25,000 hours with power factor ≥ 0.90 and total harmonic distortion (THD) ≤ 10%. The fixture shall include necessary mounting brackets, and accessories for surface/concealed installation, complete as per manufacturer’s specifications and the direction of the Engineer-in-charge |
| 76 | OD111328/2025-2026:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) (Data from ELE 90.15.4.2) |
| 77 | OD111324/2025-2026:Conveyance, installation, testing and commissioning of pre-wired fluorescent light fittings with all accessories and fluorescent lamps of all types directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required ( Data as per PWD Approved OD 90.3.1) |
| 78 | OD111330/2025-2026:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt),Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply (Data ELE 90.4.5.4) |
| 79 | OD111329/2025-2026:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 starrated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class ofinsulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (toleranceas per IS : 374-2019), THD less than 10%, remote or electronic regulator unit forspeed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required. (Data from DAR ELE 19.1) |
| 80 | OD111325/2025-2026:Supply and installation of suitable size MS rod type fan clamp in theRCC slab as per IS 732 as required. (Data from ELE 90.15.4.2) |
| 81 | OD111323/2025-2026:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required. (Data from PWD Approved OD 90.4.9) |
| 82 | OD111322/2025-2026:Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan ( Data from PWD Approved OD 90.4.10) |
| 83 | OD111327/2025-2026:Supplying and fixing 63, HRC Fuse with HRC Fuse link with connections, in existing meter board |
| 84 | OD115154/2025-2026:Charges for obtaining a new electric connection from the Kerala State Electricity Board (KSEB), covering the cost of application fee, consumer deposit (CD), ownership and yard clearance (OYC) charges, service connection charges, and any other statutory fees as per prevailing KSEB norms. The rate shall include all expenses for processing the application, site inspection, service line extension if required, installation of meter,and shall be paid to KSEB against proper demand note and receipt. |
| 85 | Furnishing and interior |
| 86 | 9.168:Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) |
| 87 | 10.16.3:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes |
| 88 | OD118349/2025-2026:Providing and fixing factory-made PVC louver wall panels of minimum 10 mm thickness, made from rigid, lead-free and termite-proof polyvinyl chloride (PVC), conforming to relevant IS standards or approved international specifications. The panels shall have a decorative louvered profile with a tongue-and-groove or interlocking edge system, and a smooth, UV-resistant surface available in plain, wood grain, or designer finish as approved by the Engineer-in-charge. Each panel shall be a minimum of 100 mm in width and supplied in standard lengths suitable for the site conditions. The panels shall be fixed over a suitable frame made of PVC, GI, or seasoned wood sections using corrosion-resistant screws, nails, and approved adhesive wherever necessary. All joints shall be concealed using matching PVC joining profiles, with corners and edges finished neatly using factory-moulded PVC trims and end caps to ensure a seamless and durable installation. The work shall include all materials, labor, scaffolding, consumables, accessories, and tools required to complete the panelling in all respects as per the directions of the Engineer-in-charge. |
| 89 | 9.170.1:Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.200 mm |
| 90 | 9.81.1:Providing and fixing bright finished brass handles with screws etc. complete:125 mm |
| 91 | 9.80:Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws. |
| 92 | 9.172:Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. |
| 93 | 9.114.1:Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters, including fixing with necessary screws etc. complete.Triple strip vertical type |
| 94 | 9.79.2:Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.50 mm |
| 95 | 9.70.1:Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete:125x64x1.90 mm |
| 96 | OD124203/2025-2026:Executive High back revolving chair (Special type) |
| 97 | OD124204/2025-2026:Supply of revolving chair medium back with push back. |
| 98 | OD124202/2025-2026:Plastic moulded Armed chair Good quality- IS 13713 (1993): Plastic chairs for general office |
| 99 | Truss Work & Steel works |
| 100 | 10.16.3:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes |
| 101 | 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 102 | OD250098/2024-2025:Providing & fixing Poly carbonate solid sheet up to 2 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete up to any distance in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required. |
| 103 | 10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 104 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 105 | 13.105:Re-lettering with black Japan paint of approved brand and manufacture. |
| 106 | Solar Power plant - On grid System |
| 107 | OD119294/2025-2026:Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plantconforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solarcells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structureof suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming toIS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Moduleconversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, threephase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency notless than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid VoltageFrequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and terminationarrangement for incoming and outgoing cable along with glands, lugs and other accessories etc.as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copperconductor 1.1 kV grade armoured power and control cables between solar modules, main powercable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs andother accessories etc. as required. |
| 108 | OD127682/2025-2026:Providing and fixing 3000 VA Home UPS, 24V DC input, of approved make, suitable for uninterrupted power supply applications. support pure sine wave output, and include advanced microprocessor-based control, automatic changeover, overload protection, short-circuit protection, and battery deep-discharge protection. The unit shall have LED/LCD indicators for status and fault display. Installation shall include transporting to site, mounting in the designated location, connecting to the existing battery bank and load circuits, and testing for proper operation as per manufacturer’s guidelines. The rate shall include the cost of the UPS, all accessories, cables, connectors, tools, consumables, and all labour charges required for complete installation and commissioning to the satisfaction of the Engineer-in-Charge. |
| 109 | OD127683/2025-2026:Providing and fixing 100AH / 25.6V LiFePO₄ (Lithium Iron Phosphate) battery, designed for energy storage applications, with a nominal capacity of 2.5 units (kWh) per battery. The battery shall have high cycle life, deep discharge capability, inbuilt Battery Management System (BMS) for overcharge, over-discharge, short-circuit, and temperature protection, and be housed in a robust casing suitable for indoor installation. The rate shall be inclusive of the cost of the battery, all necessary interconnecting cables, lugs, terminals, tools, accessories, consumables, and all labour charges required for complete installation and testing to the satisfaction of the Engineer-in-Charge. |
| 110 | Networking |
| 111 | OD124224/2025-2026:Providing and fixing D-Link Cat6 cable in suitable lengths for data networking, laid through 25 mm medium class PVC conduit conforming to ISI standards, including all necessary bends, junction boxes, couplers, saddles, and other required accessories. The rate shall be inclusive of the cost of all materials, accessories, tools, consumables, and all labour charges required for complete execution of the work to the satisfaction of the Engineer-in-Charge. |
| 112 | OD124250/2025-2026:Providing and fixing network wall mount box of approved make and size, suitable for housing networking equipment.The rate shall include the cost of the wall mount box, all accessories, tools, fasteners, consumables, and all labour charges for complete installation to the satisfaction of the Engineer-in-Charge. |
| 113 | OD124249/2025-2026:Providing and fixing TP-Link Gigabit 24-Port Network Switch of approved model, suitable for high-speed Ethernet networking, conforming to IEEE 802.3 standards.The rate shall include the cost of the switch, all necessary accessories, tools, consumables, and all labour charges required for complete installation to the satisfaction of the Engineer-in-Charge. |
| 114 | OD124248/2025-2026:Providing and fixing factory-made patch cord of 1.5 metre length, Cat6, of approved make.The rate shall include the cost of the patch cord, all accessories, tools, consumables, and all labour charges required for complete connection and testing to the satisfaction of the Engineer-in-Charge. |
| 115 | OD124247/2025-2026:Providing and fixing RJ-45 connectors of D-Link make, Cat6 type, suitable for use with Cat6 UTP cables, conforming to relevant ISO/IEC and TIA/EIA standards. The rate shall be inclusive of the cost of connectors, all necessary tools, accessories, consumables, and all labour charges required for complete installation to the satisfaction of the Engineer-in-Charge. |
| 116 | OD127878/2025-2026:Supply, Installation of A4 Black and White Laser Printer, Perfect for Home & Office- Print speed up to 20 ppm (black)USB, Mobile printing |
| 117 | Office shifting and Miscellaneous |
| 118 | 100.98.1004:Engaging Carpenter Ist class. |
| 119 | 100.98.1032:Engaging Technician. |
| 120 | 100.98.1008:Engaging Coolie. |
| 121 | OD119495/2025-2026:Providing vehicle on hire basis for the conveyance of office files, computers, printers, units, and other related equipment from the existing office to the designated location. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail