| 1 | Surface excavation in soft/loose soil n.exc 30cm deep and averaging 15 cm deep and getting out complete all as as directed. |
| 2 | Excavation in Trenches not exc. 1.50 Metre Wide and not exc. 1.50 Metre in Depth for Foundation, laying of cable etc. or for Shafts, Wells, Cess Pits, Manholes, Pier Holes etc. not exc. 10 Sqm on Plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 3 | Returning filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm, complete all as specified and directed. |
| 4 | Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed. |
| 5 | M&L for PCC (1:4:8) type-D2 with using 40 mm graded crushed stone aggregate as foundation filling and mass concrete etc complete all as specified and as directed. |
| 6 | M&L RCC nominal mix using Type B1 1:1.5:3 (20 mm graded aggrgate for beams, cantilevers, roof beam , lintels over 1.5 m span, etc, complete all as specified and directed. |
| 7 | M & L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, banding spirally for hooping columns, hooking end and binding with and including mild steel wire not less than 0.90 mm dia (annealed) complete all as specified and directed . |
| 8 | S & F mild steel TMT bar 5 mm dia and over upto and including 10mm dia in strrups as in including cutting, bending and binding with and including mild steel not less than 0.9 mm dia (annealed) complete all as specified and directed . |
| 9 | M&L Form work for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rought finished surfaces of concerete complete all as specified and directed. |
| 10 | M&L for brick work with sub class B bricks built in cement mortar 1:6 straight or curved on plan exceeding 6mtr mean radius, complete all as specified and directed. |
| 11 | M&L for 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 (Using 12.5 mm graded stone aggregate) mixed with WPC as per manufactures instruction with a coat of hot blown bitumen of Grade VG-10 @ 1.5 Kg/Sqm and blended with clean dry sand @ 0.05Cum/Sqm complete all as specified and directed.Note:- WPC shall be measured & paid separately |
| 12 | M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth, without using extra cement, complete all as specified and directed.. |
| 13 | M&L 20mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 10mm) mixed with and including water proofing compound in top layer as per manufacturer's instructions, finishing the surface even and smooth without using extra cement complete all as specified and as directed. |
| 14 | Supply only integral Water Proofing Compound |
| 15 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed. |
| 16 | M&L Sand filling under floors or in foundations including watering and conosoldiation complete all as specified and directed. |
| 17 | M&L for hardcore of gauge n.exc. 63 mm,with broken stone and boulder, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfaces complete all as specified and directed. |
| 18 | M&L 100mm thick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as sub base of floor finished even and fair complete all as specified and directed. |
| 19 | S&F for solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet rainforced with MS square tube in opening as per specification & as directed. |
| 20 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes far top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 21 | M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed with adhesive compound as per manufacturer instruction and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6, for laying floor finishes, complete all as specified and directed. |
| 22 | M&L Glazed ceramic coloured tiles in vertical surfaces 450x 300x 7 mm thick set and jointed with adhesive compound as per manufacturer instruction & pointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed. |
| 23 | S&F for anodised powder coated aluminium ventilator with frame of weight not less than 0.75 Kg/ RM and shutter of weight not less than 0.55 Kg/ RM lowers type incl necessary fittings and 4.00 mm thick frosted glass, complete all as specified and directed. |
| 24 | S&F color coated (SDP) pre painted galvalume aluminium zinc coating AZ150 GI based corrugated steel sheet 0.5 mm thick (BMT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self taping screw, butyl tape, end foam filler including dismantling plain or corrugated steel sheeting any gauge, thickness in roof covering as specified. |
| 25 | S&F roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam tee, angle, channel or flat sections) including clits etc conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed. |
| 26 | S&F Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm, Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to Aluminium framework with screws all as specified complete complete all as specified and directed. |
| 27 | M & L for 4mm thick Non Asbestos designed Cement E board incl two coats of distempering in one side incl preparation of new surface of board as approved by GE of size fixed in ceiling as specified and directed. |
| 28 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section,complete all as specified and directed. |
| 29 | S&F aluminium alloy 200mm anodised sliding door bolts with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast - aluminium alloy and fixed,complete all as specified and directed. |
| 30 | S&F 75mm MS butt hinges medium weight, complete all as specified and directed. |
| 31 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised,complete all as specified and directed. |
| 32 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, including taking out old unserviceable 15mm bore GI pipe complete all as specified and as directed. |
| 33 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors including taking out old unserviceable 20mm bore GI pipe complete all as specified and as directed. |
| 34 | Supply and fix 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 35 | S & F 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed. |
| 36 | S&F 15mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 37 | S&F PVC connector 600mm long with brass coupling in both ends screwed down for iron pipe complete all as specified and as directed. |
| 38 | S&F 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated, fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed |
| 39 | S&F vitreous China wash basin, white, flat back, size 550x400mm including brackets cutting for and pinning in ends of brackets or erecting stand, and 32 mm bore Waste coupling of PTMT (half or full hreaded) including weste pipe.(Minimum weight 32mm-45gms) complete all as specified and as directed. |
| 40 | S&F Vitreous China squatting pan \\"Orissa\\" pattern size 580x440mm white with integral foot rest , including S or P traps (Excluding flushing cistern & flush pipe), laid over 150mm thick cement concrete (1:5:10) type E2 using (40mm graded aggregate) of complete all as specified and directed. |
| 41 | S& F for Vitreous China (Pedestal pattern) Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. pipe) incl PVC seat cover complete in all respect all as specified. “long pan”, size 580 mm white with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified and as directed. |
| 42 | S&F health faucet with 15mm dia, 1.25 meter long easy flexible tube in chrome finish & wall hook all as specified and as directed |
| 43 | S&F 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with in let ball valve float and handle, PVC flush pipe, complete all as specified and as directed. |
| 44 | S&F 32mm bore dia Waste coupling of PTMT (half or full threaded) minium weight 45 gms) incl 32mm dia weste pipe |
| 45 | Supply and fix in repair 600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers including taking down old unserviceable mirror ,complete all as specified and directed. |
| 46 | S&F stainless steel Soap dish, any type, fixed to wall with chromium plated brass screws complete all as specified and as direceted. |
| 47 | S&F Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed. |
| 48 | S&F aluminium anodised plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges,complete all as specified and directed. |
| 49 | S&F Corner glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chomium plated bracket guard & railing 45 cm long, complete all as specified and directed. Make : Code No. ACN-1173 of Jaquar. |
| 50 | S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed. |
| 51 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floor complete all as specified and as directed. |
| 52 | S&F 75 mm bore PVC (SWR) bends of any radius,complete all as specified and directed. |
| 53 | M&L100mm dia of outlet, PVC floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 54 | S&F 110 mm bore PVC (SWR) pipes double socketed in any length with rubber ring joints laid in trenches or floors complete all as specified and as directed. |
| 55 | S&F 110 mm bore PVC (SWR) bends of any radius,complete all as specified and directed. |
| 56 | Cutting into existing manholes of 150 mm dia for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, complete all as specified and directed.. |
| 57 | S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed,complete all as specified and as directed. |
| 58 | S&F in repair, 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) complete all as specified and directed . |
| 59 | M&L for preparation of new plastered surfaces of walls and applying two coats of acrylic distemper including one coat of chalk whiting on plastered surface to preparatory to distempering complete all as specified and directed. |
| 60 | M&L for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 61 | M&L preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 62 | Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 63 | M&L for Cortex Tile made up of 'Wood fiber cement composite' 1mm width wood fiber 15mm thick covered with Acoustically Transparent Woven Fabric on the front side, with an option of colors of size 595X595 mm having excellent noise absorption of 1 NRC (for the base panel) as per ISO: 354. Fire Ratings as per BS 476 Part 5,6 and 7 class 1 and P, water resistant and thermal insulated. Installed on T24 grid system of 0.6mm thick Main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per Fire Retardant IS 15061-2002 for excellent results complete all as specified and as directed.Note: Test Certificates for 1. Non-Combustible as per S-476-Part-4-1970,2. Fire Propagation Index (I=1.2) as per BS-476-Part-6-1989+A1:2009, 3. Surface Spread of Flame (Class-1) as per BS-476-Part:7-1997, 4. Ignitability (Class P) as per BS-476-Part-5-1979, 5. Fire resistance (60 Minutes) as per BS-476 Part-20/22 are must before execution of work. |
| 64 | M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation filling in and mass concrete including necessary demoliation of existng existing concrete complete all as specified and as directed. |
| 65 | Supply and fixing Rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-290 (Gde E-165) and applying a coat of red oxide zinc chrome primer including dismantling/taking out old unserviceable one complete all as specified and as directed. |
| 66 | S&F Rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to Fe.290W. Gde-E- 165) quality A) including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 67 | M&L preperation of new plastered surfaces of walls and applying two coats of white wash,complete all as specified and as directed. |
| 68 | M&L lead free tiles in vertical surface of 300x600x7 MM thick set and jointed in adhesive compound as per manufacturer's instruction & painted in white or colour cement to match incuding backing coat 10 mm thick in CM 1:4 and used adhesive when as required complete all as specified and as directed by Eng-in-charge. |
| 69 | S&F powder coated (minimum thickness of poweder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. |
| 70 | S&F Powder coated Anodised aluminium (minimum thickness of powder coating 50 micron) Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified. |
| 71 | S&F 4 mm thick Sheet glass, ordinary quality and glazing with wooden beads in squares not exceeding 0.5 Sqm in each pane, complete all as specified and as directed. |
| 72 | M&L 12mm thick Prelaminated particle board, Exterior grade, prelaminated both side with decorative choice lamination complete all as specified and directed. |
| 73 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing as specified in SSR Part I, Section 8 complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 74 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing as specified in SSR Part I, Section 8 complete all as specified and as directed. Please Enable Macros to View BoQ information |