| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft and loose soil complete all as specified and directed. |
| 2 | Material and Labour for plain cement concrete, 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 3 | Material and Labour for Reinforced cement concrete (design mix) in M-25 (20mm graded stone aggregates) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concretecomplete all as specified and directed. |
| 4 | Material and Labour for Reinforced cement concrete (design mix) in M-25 (20mm graded stone aggregates) in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 5 | Material and Labour for Reinforced cement concrete (design mix) in M-25 (20mm graded stone aggregates) in roof Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 6 | Material and Labour for Reinforced cement concrete (design mix) in M-25 (20mm graded stone aggregates) in roof Slab supported in walls beams and columns in roof ,Landing, balconies, deck slabs and in shelves and similar work complete all as specified and as directed. |
| 7 | Material and Labour for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces complete all as specified and directed. |
| 8 | Material and Labour for Formwork to sides of pillars, posts, struts, piers, columns and stanchions Square, Circular rectangular on plan or polygonal complete all as specified and directed. |
| 9 | Material and Labour for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.on flat rough surface complete all as specified and directed. |
| 10 | Material and Labour for Formwork to soffits of suspedded slabs such as roof slabs, floor slabs landings and similar work ,vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed. |
| 11 | Material and Labour for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified and directed. |
| 12 | Material and Labour for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified and directed. |
| 13 | Material and Labour for rendering 10mm thick in cement mortar 1:3 on ceiling surface, finished even and smooth without using extra cement complete all as specified and directed. |
| 14 | Material and Labour for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 15 | Material and Labour for mild steel TMT bars 6 mm to 8 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 16 | Material and Labour for Precast cement concrete block masonry type C1 1:3:6 (20mm stone graded aggregate) with solid blocks, exc. 10cm in width and, setting in cement mortar 1:6 complete all as specified and directed. |
| 17 | Material and Labour for PCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregate), as in lintels upto 1.5 m clear span, cills, steps,seismic and other similar bands, plinth course, string courses, lacinng courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 18 | Material and Labour for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 19 | Material and Labour for Hardcore of broked stone or boulder gauge exc 63mm but n. exc 100mm, deposited , spread and levelled in layers n.exec 15 cm thick, watered and rolled/rammed to a tue surface complete all as specified and directed. |
| 20 | Material and Labour for 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone agg) in sub base of floor is to be rough finished complete all as specified and directed. |
| 21 | Material and Labour for 75mm thick, PCC (1:3:6), Type C-1, using 20mm graded stone aggregate as in Plinth protection etc surface finished even and fairwithout using extra cement including necessary form work if required, provision of vertical joints at 2 mtr centre to centre all as directed by Engr -in- charge. |
| 22 | Material and Labour for Non Skid Ceramic tiles, Coloured, of size exceeding 0.06 Sqm and not exceeding 0.11 Sqm,7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed. |
| 23 | Material and Labour for Glazed Ceramic Coloured tiles of size 300mmX600mmX7mm as in Vertical Surfaces such as Skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of 10mm thick in cement mortar 1:4 complete all as specified and as directed. |
| 24 | Supply and Fix aluminium louvered ventilators of section size 100mmx25mmx1.50mm including frosted glass 4mm thick fixed in half portion & adjustable type louvers in another half and stainless steel wire mesh 0.36 mm dia and 1.40mm avg width of appartaure fixed type on outside frame etc. including taking down existing steel ventilator taking down ol ventilator all as directed by Engr-in-Charge. |
| 25 | Supply and Fix aluminium powder coated window sliding type (3 track) with frame size 100x35x1.20mm and shutter 39.40x17.70x1.20mm with two glass shutter and one stainless steel wire mesh shutter including necessary jointing cleats, glazing clips, rubber packing powder coated aluminium snap beading screws with 4mm thick plain float glass and 0.36 mm dia and 1.40mm avg width of appartaure SS wire mesh, fittings etc, and necessary locking arrangements and including making good the jambs and painting with matching type and shade including taking down existing steel window all as directed by Engr-in-Charge. |
| 26 | Supply and Fix Solid coloured PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening of Sintex or its equivalent make as approved by Accepting Officer complete all as specified and as directed. |
| 27 | Supply and Fix Factory made coloured solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC \\"C\\" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement supplying & fixing in frame at site as per specification & drawing of Sintex or its equivalent make as approved by Accepting Officer complete all as specified and as directed. |
| 28 | Supply and Fix Aluminium anodised barrel tower Bolt of 150 mm size of extruded section complete all as specified and as directed. |
| 29 | Supply and Fix Aluminium cast type anodised Handle, size 150mm long complete all as specified and as directed. |
| 30 | Supply and Fix 100 mm size, heavy weight Butt Hinges, cold rolled, mild steel including fixtures complete all as specified and as directed. |
| 31 | Supply and Fix Aluminum aodised sliding door bolts, bearing ISI mark, 300mm long with hasp and staple(bolt type) and fixing clips of sheets ,cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 32 | Material and Labour for applying two coats of cement base paint on plastered surfaces of walls including preparation of new surface complete all as specified and directed. |
| 33 | Material and Labour for applying three coats of white wash to newly plastered surface of ceiling including preparation complete all as specified and directed. |
| 34 | Material and Labour for applying two coat of oil bound distemper over a coat of primer to newly plastered surface including preparation of new plastered surfaces to wall all as specified and directed. |
| 35 | Supply and Fix 15 mm bore tubes, medium grade, galvanised, with all fitting & fixed complete to walls & ceiling or laid in floors, all as specified and as directed [The rate is deemed to be included for concealing of GI tubes wherever required and directed]. |
| 36 | Supply and Fix looking mirror of any size n.exc 2.00 sqm & 5mm thick mirror of selected quality glass,,mounted on 6mm thick commercial plywood and bevelled edge fixed on wall with six nos. stainless steel studs decorative type complete all as specified and as directed by the Engineer-in-Charge (make Modi Guard/Saint Globin) |
| 37 | Supply and Fix fancy type two way Bib cock 15mm dia , fancy type, chromium plated with capstan or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and suitable for 15 bore of pipe fixed all as specified and directed (Make :Jaquar/Hindware/Cera/Prayag). |
| 38 | Supply and Fix for fancy type CP brass angular stop cock 15 mm dia all as per directed (Make :Jaquar/Hindware/Cera/Prayag). |
| 39 | Supply and Fix PVC connection of 600 mm length, suitable for 15 mm bore pipe with PTMT nuts, complete all as specified and directed. |
| 40 | Supply and Fix fancy type heavy duty health faucet chromium plated (ABS Body) with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook fixing to 15 mm bore of pipe all as specified and directed.(Make :Jaquar/Hindware/Cera/Prayag). |
| 41 | Supply and Fix CP grating ring or frame square or round 100mm size complete all as specified and directed. |
| 42 | Supply and Fix wash down water closet EWC vitrious china white in colour one piece (incl flush cistern , seat cover) with all fitting complete and fixing with outlet pipe complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar/ Cera/Hindware/ Parryware. |
| 43 | Supply and Fix table top vitreous china wash hand basin white size 460x342 / 560x450mm above miniumum depth 155mm or above under counter oval type including bottal trap, coupling making good as specified and directed.and all connecting accessories, etc (first quality) complete all as specified and as directed by Engineer-in-Charge.Make : Jaquar/ Cera/Hindware/ Parryware. |
| 44 | Supply and Fix Vitreous china Urinal half stall type white, with grating and union for discharge pipe fixed including all reqd necessary fittings as per instructions of manufacturers, bottal trap , fixing to existing wall complete all as specified.Make : Jaquar/ Cera/Hindware/ Parryware. |
| 45 | Supply and Fix PVC (SWR) pipes 110mm dia ,single socketed in any length with rubber ring joints laid in trenches or floor & wall complete all as directed. |
| 46 | Supply and Fix PVC (SWR) pipes 75 mm dia ,single socketed in any length with rubber ring joints fixed and laid in trenches or floor/ceiling and wall all as directed. |
| 47 | Supply and Fix 15 mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified. |
| 48 | Supply and Fix PVC (SWR) bends any radius, 75mm dia pipe complete all as specified and directed. |
| 49 | Supply and Fix PVC (SWR) branch piece 110 mm bore, single Y equal or unequal all as specified and directed. |
| 50 | Supply and Fix PVC (SWR) junction 110mm bore single T equal or unequal all as specified and directed. |
| 51 | Supply and Fix in repairs Powder coated Aluminium grill of approved pattern using channel of required size, screwed to windows & ventilators with self tapping screws all as specified & directed |
| 52 | Material and Labour for 20mm thick Granite work (table rubbed and polished) in steps, jambs, cills, WHB platforms,counter tops and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 20mm Screed bed in CM 1:4, all as specified and directed.Note : The rate quoted is deemed to be included for full moulding of edges and making, opening for kitchen sink all as directed by Engr-in-Charge. |
| 53 | Cutting chases, pinning in concrete block walls, making good to facing where required and pointing in cement mortar (1:3) and making good , cutting n.exc 10cm girth all as specified and directed. |
| 54 | Supply and Fix in repairs for towel ring chromium plated brass fancy type complete all as specified and as directed by the Engineer-in-Charge. (Make :Jaquar/Hindware/Cera/Prayag ). |
| 55 | Supply and Fix Rotational moulded Polythene [HDPE] Water Tanks, Cylindrical & Vertical Type 500 Liters Capacity triple layered 'ISI' marked, hoisted and fixed in position including provision of 40mm/25mm dia spouts of PVC for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed. |
| 56 | Supply and Fix 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) complete all as specified and as directed. |
| 57 | Material and Labour for applying roof treatment as under :-(i) Providing 10mm thick (average) rendering in cement mortar 1:3 mixed with WPC as per manufacturer's instruction (to be measured separately as supply only) for levelling to a true surface and to receive new roof treatment complete.(ii) Providing a coat of bitumen primer @ 0.40 Litre/Sqm over plastered surfaces of roof including parapet surfaces.(iii) Providing one layer of APP based polymeric membrane of approved manufacturer, 3mm thick, weight not less than 3.50 Kgs per Sqm, reinforced with polyester non woven fabric (weighing not less than 150 Gms/Sqm). Polymeric membrane shall be taken to a height 60cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note:(a) Laying of APP based polymeric membrane shall be done by torch application method or as per manufacturar's instruction. (b) Side overlaps shall be minimum 75mm and end laps shall be minimum 100mm and sealing all overlaps and joints as per manufacturer's instructions. (c) The make of polymeric membrane shall be as per PS Specification of CA.(iv) Applying two coats of bituminous aluminium paint on top of APP membrane. |
| 58 | Supply and Fix in repair (any type & size of door) aluminium anodised door with frame and shutter and glazing 5 mm thick tinted glass or 12 mm thick prelaminated particle board exterior grade in panels, rubber gasket, aluminium glazing clips, mortice lock, Aluminium stopper cleat, hydraulic double action floor door spring, iron mongary etc. section of aluminium door including powder coating of any colour (min thickness of powder coating 50 micron) shall be of following sizes:-Frame : 100 x 44 x 1.80 mm thick with rawal plugMiddle lock rail: 100 x 44 x 1.80 mm thickBottom rail : 100 x 44 x 1.80 mm thickTop rail / Style: 46 x 44 x 1.80 mm thickGlazing beading: 0.70 mm thickAluminium handle 'D' type: 150 mm Aluminium tower bolt 9.9 mm dia shoot 200 mm long Mortice lock – 100 mm 4 lever,Aluminium stopper cleat Note :- (i) Making good of wall surface with matching to existing surface complete all as specified and directed.(ii) Making good floor surface after fixed hydraulic double action floor door spring with matching to existing surface complete all as specified and directed. |
| 59 | Material and Labour for PCC M-7.5 grade nominal mix using 40 mm graded stone aggregate as in concrete bed to drain pipes including packing under and haunching against sides of pipes with concrete after they are laid and bedded dia of pipe 150mm all as specified and directed. |
| 60 | Material and Labour for 150mm dia RCC drain pipes class NP2 laid in trenches and jointed with in cement mortar all as specified. |
| 61 | Material and Labour for 10 users Hume pipe septic tank designed to carry sewage and sludge water excavated in any type of soil, PCC 1;4:8 below foundation, vent shaft connection etc all as directed. |
| 62 | Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM 1:6, RCC cover slab in M25 , interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4M dia X 4.5 M effective depth complete all as specified and as directed. |
| 63 | Material and Labour for 75mm thick PCC 1:4:8 type D2 ( 40 mm graded stone aggregates) as ins sub base of floor complete all as specified and as directed. |
| 64 | Material and Labour for Prepolished Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in near cement slurry in floors with grey cement and pigment including 20mm thick screed bed in CM 1:6 all as specified and as directed. |
| 65 | Excavating in trenches, not exc. 1.5mtr wide and not exc. 1.5 mtr in depth for laying of cable and pipe line in Complete and all as specified the following. |
| 66 | Soft / loose soil |
| 67 | Hard/ dense soil |
| 68 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed by Engineer- in-Charge. |
| 69 | Removing excavated material not exeding 50 mtr and depositing where directed at a level not exeeding 1.5 mtr above the starting point Complete and all as specified and directed by Engineer- in-Charge. |
| 70 | Supply and Fix galvanized iron water tubing medium grade conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 at Incoming of the service tanks / Fresh water line of kitchen complete all as required at site for branch connection including cutting threading complete all as specified & directed by Engineer-in-charge. for following:- |
| 71 | 20 mm dia bore |
| 72 | 25 mm dia bore |
| 73 | Supply and fix gun metal gate / globe valve of of following size with iron wheel head, screwed both ends for iron pipe and fixed. complete all as specified and as directed by Engineer-in-Charge. |
| 74 | 20 mm dia bore |
| 75 | 25 mm dia bore |
| 76 | Material and Labour for point wiring complete with and including 1.5 sqmm (nominal area) single core multi stranded copper conductor PVC insulated but unsheated FRLS cable 1100 Volts drawn in to and including concealed PVC conduit of suitable dia minimum 20mm dia includings sunken to wall including its accessories such as tee, bend ,elbow, socket and chisselling on wall complete and also making good the disturbed surfaces of wall / ceiling by cement mortar 1:4 including painting to existing surfaces and also including 1.5 sqmm PVC insulated and PVC unsheathed single core multistranded copper conductor FRLS cable 1100 V grade as earth wire and modular box including cover plate of suitable size for housing modular switch ,socket,regulators etc complete all as specified and directed by Engr-in-Charge for the following:- |
| 77 | One light point controlled by one switch |
| 78 | One Exhaust fan point controlled by one switch |
| 79 | One 3 pin 5 Amps socket outlet on independent board. |
| 80 | One 5 Amp socket outlet on same board with other switches |
| 81 | All as per item No 70 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor FRLS 1100 v grade but sheathed single core multi stranded pvc insulated unsheathed copper conductor cable 1100 volts grade for 16 Amps power point on independent board and 2.5 sqmm cable as earthwire complete all as specified and as directed. |
| 82 | Supply and fix modular switch 1 one way 6 amp 1 module complete ISI mark complete all as specified and directed. |
| 83 | Supply and Fix Modular Switch ,16 Amps Modular one Way , 1 module all as directed by engr- in- charge. |
| 84 | Supply and Fix Modular scoket, 6A 2/3 pin combined 2 module, all as specified and directed by engr- in- charge. |
| 85 | Supply and Fix Modular scoket, 6A 2/3 pin combined 2 module, all as specified and directed by engr- in- charge. |
| 86 | Supply and Fix Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and directed by Engr-in-Charge. |
| 87 | Supply and Fix PVC ceiling rose surface type three terminals type all as specified and directed by Engr-in-Charge. |
| 88 | Supply and fixing LED lights fitting 1x20W , 220V AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engr-in-Charge. |
| 89 | Supply and fixing LED security light fitting 35 watt 230 V AC outdoor type with high, pressure die cast alluminium hosing and heat resistant complete with driver, lamp, GI bend bracket 1 meter length suitable for fitting cavati for mounting on building with all acessaries with impact and corresion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as directed by Engr-in-Charge |
| 90 | Supply and Fix sheet metal enclosure MCB SPN DB 8 Way with 200 Amps rated copper bus bar 240 volts 50 Hz AC Supply Double door with magnitic locking system complete all as specified and as directed. |
| 91 | Supply and Fix MCB SPN 6 to 32 Amps C curve 10 kA 240 Volts AC Supply complete all as specified and as directed. |
| 92 | Supply and Fix MCB SP 6 to 32 amps, C curve 10 kA 240 Volts AC Supply complete all as specified and as directed. |
| 93 | Supply and Fix Single pole and neutal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified and directed by Engr-in-Charge. |
| 94 | Supply and fix Exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete ISI mark complete all as specified and directed by Engr-in-Charge. |
| 95 | Material and Labour for earthing complete in repairs with galvansihed steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 (20mm graded stone aggregate) RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. (Note: (i) Rate for achieving required depth by compressor machine if required is deemed to be included in item unit rate. |
| 96 | Supply, laying and testing cable XLPE Insulated , armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm 2 core all as specified and directed by Engineer in Charge |
| 97 | Material and Labour for Sand filling for cusoning of under ground cable laying in treanches all as specified and directed by Engr-in-Charge |
| 98 | Material and Labour for old size bricks sub class B , Designation 75 , for given protection to Under ground cable all as specified and directed. |
| 99 | Supply and laying GI tubing light grade 50mm bore, ISI marked, for cable protection complete all as specified and as directed. |
| 100 | Material and Labour for road cutting and boring of road without damage surface and inserts GI pipe and cable without any damage complete all as directed by Enger -in- charge. Please Enable Macros to View BoQ information |