| 1 | Excavation in trenches in any type soil n. exc. 1.5 Mtr in width and not exceeding1.5 Mtr in depth and getting out all as required for laying of UG cable/ poles complete all as specified and directed. |
| 2 | Excavation in trenches in any type of soil n. exc. 1.5 Mtr in width and exc. 1.5 Mtr but not exc. 3.00 Mtr in depth and getting out all as required for laying of UG cable/ poles complete all as specified and directed. |
| 3 | Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | Returing filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required complete all as specified and directed. |
| 5 | Material and Labour for dry fine sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable all as direted. Note: Punned thickness shall be measured & paid. |
| 6 | Supply and laying HT cable cover un-reinforced precast of size 300mmx180mmx40mm class HVP type 1 laying perpendicular to HT cable complete all as specified and directed. |
| 7 | Material and labour for plain cement concrete (1:4:8) type D-2 with (using 40mm graded crushed stone aggregate) as in foundations and mass concrete etc complete all as specified and directed. |
| 8 | Material and labour for plain cement concrete (1:3:6) type C-2 with (using 40mm graded stone crushed aggregate) as in coping of poles and foundation of stay etc including necessary form work, complete all as specified and directed. |
| 9 | Supply, fixing, commissioning and testing of Aerial bunched XPLE insulated with aluminium conductor stranded 11000 volt grade 3 single core cross sectional area 95 sqmm and one 70 sqmm aluminium conductor messenger for cable including anchor clamps made out of MS angle 32x32x6 mm complete with clamps and nuts and bolts for cable on poles including dismantling of existing over head conductor complete all as specified and directed. |
| 10 | Supply, laying & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminum conductor 6.35 KV (UE)/11 KV (E) grade, cross sectional area 120 Sqmm 3 core as per IS-7098 suitable for earth system laid in trenches including taking out old UNSV cable complete all as specified and as directed. |
| 11 | M & L in repairs Cable end jointing kit for 11 KV (earthed) grade cable for out door type termination heat shrinkable type joint complete with all jointing material and accessories suitable for 3 core XLPE HT armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. |
| 12 | M & L in repairs Cable end jointing kit for 11 KV (earthed) grade cable for out door type termination heat shrinkable type joint complete with all jointing material and accessories suitable for 3 core XLPE HT armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed. |
| 13 | Material and labour for lightning arresters expulsion typecomplete with all fittings, transmission class, dischargecapacity 65 kilo amp suitable for 11000 volts conforming to IS including taking down old unserviceable lightening arrestors complete all as specified and directed. |
| 14 | Supply and fixing air break switch gang operated (GOD) triple pole with drop out fuses mechanically operated, mounted on insulators (15 insulators) & steel frame with operating mechanism & operating rod of GI pipe 25mm medium grade with necessary clamps to be operated from ground level 11 KV grade working pressures and current upto 400 amps etc including taking out the unserviceable gang operated device after disconnecting the electric HT supply, complete all as specified and directed. |
| 15 | Supply and fixing aluminium conductor steel reinforced (ACSR) for HT lines on PCC/steel tubular poles, streching without kinks and bends including aluminium binding wires of size ferret to Dog as per load including taking down old existing unserviceable /old ACSR conductor from over head lines complete all as specified and directed by Engineer-in-Charge. |
| 16 | Dismantling insulators any type and size complete all as specified and directed. |
| 17 | Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height,150 mm dia for 11000 volts grade complete all as specified and directed. |
| 18 | Supply and fixing disc type insulator, porcelain, vitreous145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tensionwith tension clamps for conductors, working pressure 11000 volts complete all as specified and directed. |
| 19 | Material and labour for earthing complete with galvanised steel earth plate electrode , 600x600x6mm thick buried directly in the ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron strip 32x6mm by means of bolts, nuts and washers, check nuts of GI steel as shown in electric plate No 03 of SSR -2009 Part-I, all as specified and indicated complete and including charcoal , dust and salt etc and GI protection pipe medium grade 40mm and GI watering pipe 20mm light grade with funnel and wire mesh, 40mm thick pre-cast RCC M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for pit cover , PCC (M-15) nominal mix pit including necessary excavation and earth work in any type of soil , removal of surplus soil to a distance n.exc 50mtr and connecting , testing on completion all as specified and directed.Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor.2. Earth filling shall be done by vegitable soil.3. Soil shall be free from stone, boulders, aggregate, gravels . |
| 20 | Material and labour for earthing complete with galvanised steel earth plate electrode , 600x600x6mm thick buried directly in the ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15mm bore medium grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal , and salt precast PCC 1:2:4 (Nominal mix ) cover with suitable steel handle , and angle iron 40x40x3mm frame for pit cover , PCC 1:2:4 pit including earth work in any type of soil , removal of surplus soil to a distance n.exc 50mtr and connecting , testing on completion all as shown on electric plate No 03 of SSR -2009 Part II complete all as directed.Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor.2. Earth filling shall be done by vegitable soil.3. Soil shall be free from stone, boulders, aggregate, gravels . |
| 21 | S & F in repair and replacement of GI strip of size 25X4mm from test point to panel or other places complete all as specified and directed. |
| 22 | Material and labour for GI pipe in replacement (Light grade) for protection of HT cable fixed to walls/ poles/road crossing including suitable size clamps complete of size 80mm bore, all as specified and directed. |
| 23 | Material and labour for erection of steel tubular swaged pole type 410 SP-55 (11metre long) with 300mmx 300mmx6mm cast iron base plate, finial taper plug, bolts, nuts and screws and making holes as per requirement all as specified, including factory painting with two coats of black bituminous paint internally throughout complete and externally for embedded portion and applying one coat of red oxide primer making 05 Nos strips each, alternative white/Yellow & Black strips of 30 cm height upto 1.5 mtr above ground level/coping with two coats of aluminium paint for the remaining height complete all specified and directed.(Note: Excavation and earth work, GI pipe, clamps shall be measured and paid for separately under respective items.) |
| 24 | Material and labour in replcement of structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of zink chrome primer and two coats of aluminium paint for 11KV insulation complete all as specified and directed. |
| 25 | Supply, laying & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminum conductor 6.35 KV (UE)/11 KV (E) grade, cross sectional area 95 Sqmm 3 core as per IS-7098 suitable for earth system laid in trenches including taking out old UNSV cable complete all as specified and as directed. |
| 26 | Supply, laying & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminum conductor 6.35 KV (UE)/11 KV (E) grade, cross sectional area 300Sqmm 3 core as per IS-7098 suitable for earth system laid in trenches including taking out old UNSV cable complete all as specified and as directed. |
| 27 | Supply and fix in repair and replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT 25 x 20 cm size all as specified and directed by Engr-in-Charge |
| 28 | Labour only for repairing, replacment of broken and unserviceable parts greasing of existing GOD fitted on two pole and four pole structure of Hohrizontal/vertical type after fixing new parts testing the GOD to fix propery at Samba Military Station, Dayalchak & Galak Military Area all as specified and directed by Engr-in-Charge.. Note: The material replaced to make GOD Serviceable is paid as supply only item of schedule under Srl Item No 29 to 45 here-in-below:- |
| 29 | Supply only Post Polymer insulator 11 KV suitable for 11 KV GOD |
| 30 | Supply only Arching Horn made out of galvanized steel suitable for 11 KV GOD |
| 31 | Supply only Terminal pad suitable for 11 KV GOD |
| 32 | Supply only Male contact /moving contact blades suitable for 11 KV GOD |
| 33 | Supply only Female contract / fix contact Jaw suitable for 11 KV GOD |
| 34 | Supply only Tinner copper flexible jumper 400 Amps suitable for 11 KV GOD |
| 35 | Supply only MS Jumper carrier suitable for 11 KV GOD |
| 36 | Supply only Back connector plate suitable for 11 KV GOD |
| 37 | Supply only Steel handle and its connected nut, bolts ,washer, Screw for GOD |
| 38 | Supply only contact Gun suitable for 11 KV GOD |
| 39 | Supply only wire mesh suitable for 11 KV GOD |
| 40 | Supply only terminal clamp suitable for 11 KV GOD |
| 41 | Supply only bolt for conductor binding at ends suitable for 11 KV GOD |
| 42 | Supply only Bimetalic strip as per exisisting fixed on GOD 11 KV |
| 43 | Supply only Aluminium terminal clamp suitable for horizontal as well as vertical as per existing model 11 KV |
| 44 | Supply only fixed contact assembly as per existing model for 11 KV GOD |
| 45 | Supply only moving contact pipe assembly as per existing type for 11 KV GOD |
| 46 | Repair /servicing /Calliberation to HT panel of (Make : CG) having vacuum circuit breaker 11 KV rating of capacity 250 MVA and current rating up to 630 Amp by replacing following defective/wornout part, adjustment of gaps for smooth operation all as detailed below:-(a) Cleaning of VCB with air blower and removing dust particals.(b) Cleaning of insulating places of VCB by using CTC/CRC/Thinner as required and recommended.(c) Checking the arcing contact gap of vaccum intrupter if gap exceeds the permissible limis, readjust as recommended.(d) Cleaning the main contacts to remove carbon or any other unwanted particals if visible.(e) Dismantling and cleaning the insulated surfaces and arc barrier with CTC and CRC.(f) Checking/ repair replacement of all electrical/ manual operation of panel including measuring IR values.(g) Checking of all nuts/ bolts. springs, levers, latches, connectors etc. and adjustments as required and recommended.(h) Recording IR values of CTs and PTs(j) Cleaning of bus bar spout.(k) Cleaning of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations.Note: (i) Service will be carried out through Service Engineer of Manufacturer only. The service engineer so hired should be the manufacturer employee only. No employee of authorized dealer shall be hired for servicing of VCB.(ii) The cost of minor spare parts i.e nut and bolts, springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop. \\"Y\\" Phase shround, over ride stop pin etc essentially required to make the panel serviceable shall deemed to be included in the unit rate by contractor. |
| 47 | Repair /servicing /Calliberation to HT panel of make : ABB and Cropmton having vacuum circuit breaker 11 KV rating of capacity 250 MVA and current rating up to 630 Amp by replacing defective/wornout part, adjustment of gaps for smooth operation all as detailed below:-(a) Cleaning of VCB with air blower and removing dust particals.(b) Cleaning of insulating places of VCB by using CTC/CRC/Thinner as required and recommended.(c) Checking the arcing contact gap of vaccum intrupter if gap exceeds the permissible limis, readjust as recommended. (d) Cleaning the main contacts to remove carbon or any other unwanted particals if visible.(e) Dismantling and cleaning the insulated surfaces and arc barrier with CTC and CRC.(f) Checking/ repair replacement of all electrical/ manual operation of panel including measuring IR values.(g) Checking of all nuts/ bolts. springs, levers, latches, connectors etc. and adjustments as required and recommended.(h) Recording IR values of CTs and PTs(j) Cleaning of bus bar spout.(k) Cleaning of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations.Note: (i) Service will be carried out through Service Engineer of Manufacturer only. The service engineer so hired should be the manufacturer employee only. No employee of authorized dealer shall be hired for servicing of VCB.(ii) The cost of minor spare parts i.e nut and bolts, springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop. \\"Y\\" Phase shround, over ride stop pin etc essentially required to make the panel serviceable shall deemed to be included in the unit rate by contractor. |
| 48 | Repair /servicing /Calliberation to HT panel of make : Kirloskar having vacuum circuit breaker 11 KV rating of capacity 250 MVA and current rating up to 630 Amp by replacing defective/wornout part, adjustment of gaps for smooth operation all as detailed below:-(a) Cleaning of VCB with air blower and removing dust particals(b) Cleaning of insulating places of VCB by using CTC/CRC/Thinner as required and recommended.(c) Checking the arcing contact gap of vaccum intrupter if gap exceeds the permissible limis, readjust as recommended.(d) Cleaning the main contacts to remove carbon or any other unwanted particals if visible.(e) Dismantling and cleaning the insulated surfaces and arc barrier with CTC and CRC.(f) Checking/ repair replacement of all electrical/ manual operation of panel including measuring IR values.(g) Checking of all nuts/ bolts. springs, levers, latches, connectors etc. and adjustments as required and recommended.(h) Recording IR values of CTs and PTs(j) Cleaning of bus bar spout.(k) Cleaning of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations.Note: (i) Service will be carried out through Service Engineer of Manufacturer only. The service engineer so hired should be the manufacturer employee only. No employee of authorized dealer shall be hired for servicing of VCB.(ii) The cost of minor spare parts i.e nut and bolts, springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop. \\"Y\\" Phase shround, over ride stop pin etc essentially required to make the panel serviceable shall deemed to be included in the unit rate by contractor. |
| 49 | S&F in replacement of plug & socket assembly suitable for VCB 11 KV complete all as specified. |
| 50 | S&F in replacement of manual spring charging handle suitable for VCB/OCB 11 KV complete all as specified |
| 51 | S&F in replacement of TNC switch suitable for VCB/OCB 11 KV Panel complete all as specified |
| 52 | S&F in replacement of electric hooter suitable for VCB 11 KV Panel complete all as specified |
| 53 | Taking down unservicable triping coil from HT panel and supply and fixing new triping coil 30 volt DC suitable for 11KV HT panel of make : Kirloskar/CG/ABB as per OEM of existing panel complete all as directed and specified by Engr-in-charge. |
| 54 | aking down unservicable triping coil from HT panel and supply and fixing new Master Trip Relay 30V DC suitable for 11 KV HT panel for protection system complete all as directed and specified by Engr-in-charge. |
| 55 | Taking down unservicable triping off trip circuit supervision relay and S&F new trip circuit supervision relay of 30 V DC suitable for 11 KV HT panel for protection system complete all as directed and specified by Engr-in-charge. |
| 56 | Taking down unservicable triping off trip circuit supervision relay and S&F new trip circuit supervision relay of 110-125 V DC suitable for 11 KV HT panel for protection system complete all as directed and specified by Engr-in-chagre |
| 57 | Supply and fixing in repair and replacement of Male & Female assembly of VCB of make CG/Kirloskar/ABB |
| 58 | Supply and fixing in repair and replacement of Limit switch for 11 KV VCB as per OEM recommended Cat part as per existing model of VCB make: ABB/CG/Kirloskar |
| 59 | Supply and fixing in repair and replacement of Auxilary switch 12 NO, 12 NC for 11 KV VCB as per existing model of OEM make all as specified and directed by Engr-in-Charge. |
| 60 | Supply and fixing in repair and replacement of Potential Transformer Fuze 3 Amps for 11 KV VCB and SF 6 breaker as per existing model of OEM make all as specified and directed by Engr-in-Charge. |
| 61 | Supply and fixing in repair and replacement of RHS fuse, 2 Amps for 11 KV VCB panel as per existing model all as specified and directed by Engr-in- Charge. |
| 62 | Supply and fixing in repair and replacement of Closing coil for VCB as per exisiting OEM model all as specified and directed by Engr-in-Charge. |
| 63 | Supply and fixing in repair and replacement of Potential Transformer top mounted as per existing model for 11 KV VCB all as specified and directed by Engr-in-Charge. |
| 64 | Supply and fixing in repair and replacement of Spring charging motor and its connected wiring and its assembly as per existing OEM for 11 KV VCB all as specified and directed by Engr-in-Charge. |
| 65 | Supply and fix in repair and replacement of space heater suitable for 11 KV VCB and its connected wiring as per existing model fitted on VCB all as specified and directed by Engr-in-Charge |
| 66 | Supply and fix in repair and replacement of 11 KV indoor VCB Panel insulator all as specified and directed by Engr-in-Charge for the following make of VCBs installed at site, Kirloskar, ABB, CG, ITE Gurgaon. |
| 67 | Supply and fix in repair and replacement of 11 KV indoor VCB Trolley insulator all as specified and directed by Engr-in-Charge for the folloiwng make of VCBs installed at site, Kirloskar, ABB, CG, ITE Gurgaon |
| 68 | Supply and fix in repair and replacement of 11 KV indoor VCB power pack 220 V AC /24 V DC all as specified and directed by Engr-in-Charge for the folloiwng make of VCBs installed at site, Kirloskar, ABB, CG, ITE Gurgaon. |
| 69 | Material and labour for H-Class insulation painting on CT & Spout for 11 KV indoor VCB installed at Samba Military Station all as specified and directed by Engr-in-Charge for the following make of VCBs Kirloskar, ITE Gurgaon, CG, ABB |
| 70 | Material and technician for complete repair and replacement of control wiring of copper up to 6 sqmm inside VCB from all connected relays, DC circuit all as specified and directed by Engr-in-Charge for the following make of VCBs Kirloskar, ABB, CG, ITE Gurgaon. |
| 71 | Material and labour for spray painting of inside 11 KV indoor VCB installed at Samba Military Station all as specified and directed by Engr-in-Chaarge for the following make of VCBs Kirloskar, ITE Gurgaon, CG, ABB |
| 72 | Supply and fixing in repair and replacement of Current Transformer set 100/50-5/5 of threefor 11 KV VCB as per existing OEM model all as specified and directed by Engr-in-Charge. |
| 73 | Supply and fixing in repair and replacement of Volt meter for VCB 11 KV as per existing model and size and its connected wiring all as specified and directed by Engr-in-Charge. |
| 74 | Supply and fixing in repair and replacement of Ammeter or VCB 11 KV as per existing model and size and its connected wiring all as specified and directed by Engr-in-Charge. |
| 75 | Supply and fixing in repair and replacement of Over current relay consiting of Over current, Earth fault, for 11 KV VCB as per existing model of CG Model -CG 14 N or as per new version all as specified and directed by Engr-in-Charge. |
| 76 | Supply and fixing in repair and replacement of Over current, Earth fault relay model (61A) of 11 KV VCB Make: L & T |
| 77 | Supply and fixing in repair and replacement of Charging Gear big size suitable for VCB 11 KV of make CG/ABB/Kirloskar as per existing model all as specified and directed by Engr-in-Charge. |
| 78 | Supply and fixing in repair and replacement of Charging Gear small size suitable for VCB 11 KV of make CG/ABB/Kirloskar as per existing model all as specified and directed by Engr-in-Charge. |
| 79 | Supply and fixing in repair and replacement of Vaccum Interrupter suitable for 11 KV VCB of make CG/Kirloskar/ABB all as specified and directed by Engr-in-Charge. |
| 80 | Supply and fixing in repair and replacement of battery of capacity 2 Volts, 100 AH including its connected terminal and cable as per existing make and model all as specified and directed by Engr-in-Charge. |
| 81 | Supply and fix in repair and replacement , testing of Spring charging motor of make Crompton for SF 6 circuit breaker and check the serviceability and tripping mechanism all as specified and directed by Engr-in-Charge. |
| 82 | Supply and fix in repair and replacement , testing of Spring charging motor of make ABB for SF 6 circuit breaker and check the serviceability and tripping mechanism all as specified and directed by Engr-in-Charge. |
| 83 | Supply and repair and replacement of Tripping coil 110 V DC for SF 6 breaker of make Crompton and ABB all as specified and directed by Engr-in-Charge. |
| 84 | Supply and repair and replacement of Closing coil 110 V DC for SF 6 breaker of make Crompton and ABB all as specified and directed by Engr-in-Charge. |
| 85 | Supply and repair and replacement of Contactor of operating voltage 110 V DC for SF 6 breaker of make Crompton and ABB all as specified and directed by Engr-in-Charge. |
| 86 | Supply and repair and replacement of Auxilary switch for SF 6 breaker of make Crompton and ABB all as specified and directed by Engr-in-Charge. |
| 87 | Supply and repair and replacement of Close limit switch for SF 6 breaker of make Crompton and ABB all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 88 | Supply and repair and replacement of Close limit switch for SF 6 breaker of make Crompton and ABB all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |