| 1 | Supply, lay, jointing and testing in replacement 150 mm dia centrifugally cast (spun) ductile iron pressure pipe of following sizes with socket and spigot ends class 'K-7', ISI marked, confirming to IS: 8329/2000 suitable and including rubber gasket joint and fittings (push on) with inside cement mortar lining laid in trenches under floor complete all as specified and directed. |
| 2 | Supply and fix in replacement 150mm dia Sluice valve of following sizes with brass spindle with hand wheel of class PN 1.6, conforming to IS 14846-2000 including suitable size bolts, nuts, washer and rubber gasket complete all as specified and directed. |
| 3 | Cutting DI line of any size 150 mm dia and insertion of any size up to 100mm of CI Tee unequal of size reducer tee, fixing connecting GI pipe of required size pipe with flange type complete with all fittings complete all as specified and directed. |
| 4 | Construction of Valve chamber of size 1.2X1.2m x1.0 M with brick masonry and MS sheet cover complete all as specified and directed. |
| 5 | M&L in replacement for galvanized steel water tubing medium grade of 50mm bore with & including all fittings complete laid in trenches complete all as specified and directed. |
| 6 | M&L in replacement for galvanized steel water tubing medium grade of 80mm bore with & including all fittings complete laid in trenches complete all as specified and directed. |
| 7 | M&L in replacement for galvanized steel water tubing medium grade of 100mm bore with & including all fittings complete laid in trenches complete all as specified and directed. |
| 8 | S&F in repairs 50mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipe, ISI marked complete all as specified and directed. |
| 9 | S&F in repairs 80mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipe, ISI marked complete all as specified and directed. |
| 10 | Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation etc or for laying of cables, pipes etc in soft/loose soil and getting out complete all as specified and directed. |
| 11 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed. |
| 12 | Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed. |
| 13 | Trial bore holes 150mm dia in any type of strata of bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer - in charge complete including submitting the strata details both graphically recorded as well as strata results complete all as specified and directed.Note :- The rates quoted shall deemed to include to get survey done for availability/facibility of water as recommended by CGWD before execution of work. |
| 14 | M&L for bore by drilling with rotary system/ODEX system of 250mm dia in hard rock /Disintigrated rock till meeting water strata complete all as specified and directed. |
| 15 | All as per item No 14 above but of 250mm dia in hard rock and drilling with DTH system till meeting water strata complete all as specified and directed. |
| 16 | Supplying and assembling jointing lowering and fixing in position of ERW MS casing pipe 200mm dia of 5.4mm thickness (minimum) upto required depth below ground level in all strata (including cutting welding as required, painting etc complete ISI marked including MS well cap and also as specified and directed by Engr-in -charge. Make - TATA/Swstik/Jindal/Prakash |
| 17 | Supply, assembling, including jointing lowering and fixing in position ERW MS slotted pipe 200mm dia of 5.4mm thickness ( minimum ) having slots of 1.59 mm wide, 75 mm long assembled and lowered as per location chart approved by the GE including cutting welding as required and painting etc complete all as specified and directed. |
| 18 | Development of tube well by compressed air with compressor of minimum capacity of 150 PSI and 450 CFM complete all as specified and directed.Note:- (i) Yield test for the bore well by continuously pumping to determine safe pumping yield to be carried out by contractor at site and necessary report to be submitted (ii) Testing of water for potability, dissolved solids, physical/chemical and bactorogical testing etc from the govt lab shall be carried out by the contractor all as directed and test report shall be submitted. (iii) The rates quoted shall deemed to include the above provisions. |
| 19 | S & F housing clamp 90 cm long 20 cm wide out of 6 mm thick MS plate for 200mm dia casing pipe with necessary MS Bolts, nuts & washers at ground level in PCC (1:2:4) type B1 using 20 mm graded stone aggregate in block complete all as specified and directed. |
| 20 | M & L for strata sample box of second class hard wood ( Hollock / Bijasal ) of size 40cm x 30cm x 20 cm complete all as specified and directed. |
| 21 | M & L in replacement for 50 mm bore GI medium grade column pipe in 6 m length with flanged joints duly scewed and welded with pipe suspended in deep well complete with slote for lead, GI flanges, rubber gaskat clamps, bolts, nuts, etc all as required for completion of work complete all as specified and directed. |
| 22 | S&F non return valve cast iron body flanged ends & drilled horizontal heavy duty including jointing material etc. complete ISI marked of size 80 mm bore for submersible pump complete all as specified and directed. |
| 23 | S&F sluice valve, cast copper alloy, PN 1.6, of size 80 mm dia complete including connecting complete all as specified and directed. |
| 24 | Supply installation Testing and commissining submersible pump set Electric driven 3 phase, 415 volt, 50 c/s having discharge upto 14000 Lit / hrs at 180 m head 18 stage not less than 15 HP complete all as specified and directed. Make- KSB/Kirlosker/CG. |
| 25 | Supply, install, testing & commissioning of LT panel outdoor type (KIOSK) factory made powder coated paint made of 3 mm thick CRCA sheet, CPRI approved, dust and vermin proof protection, with 200 Amps copper bus bars front opened with locking arrangements mounted on angle iron frame 40x40x6mm, 45cm height from ground level comparising of the following accessories :-(a) MCCB 100 Amp 16 KA rating 4 pole 440 volts-01 No Make-ABB/Legrand/L&T(b) MCB-63 Amps, TPN 440 V, 16 KA-01 No Make-ABB/Legrand/L&T(c) Starter, star delta, fully automatic suitable for 15 HP 3 phase elect motor - 01 No Make-L&T/Havells/AE(d) Digital Amp meter with selector switch & CT 0-50 Amps - 01 No(e) Digital Volt meter with selector switch 0-500 Volts -01 Nos(f) Single phase preventor mini lec VSP-II-01 No Make-Havells/ABB/L&T/BCH/C&S(g) Phase sequance corrector 15 HP motor, 3 phase-01 No Make-Havells/ABB/L&T/BCH/C&S(h) LED Indicator lamp - 03 Nos (RYB)(j) Wiring with suitable size copper conductor cable for LT panel.(k) Power factor correction capictor bottle type, 3 KVAR 3 phase- 01 No Make- Legrand/ABB/EPCOS |
| 26 | S & F 1100 Volts grade submersible cable flate 3 core with copper conductor 10 sqmm stranded fixed to column pipes with suitable clamps jointing material complete. Note: two parallel runs of cable shall be measured and paid as one running meter complete all as specified and directed. |
| 27 | M&L Earthing complete with galvanised steel earth plate eletrode 60xm x 60cm x6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to galvanised earth strip 25x4 mm by means of bolts, nuts check nuts and washer of galvanised iron or steelupto test point all as shown in electrical plate No 3 of SSR Part-I connected to test point incl PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40mm dia for earth lead protection from earth plate to test point and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion. |
| 28 | M&L for providing cement concrete in foundation, filling and mass concrete all including required from work etc. complete type B-2 1:2:4 for sealing bactorogical treatment/surface complete all as specified and directed. |
| 29 | S&F , digital water flow meter cast iron body flanged ends & drilled horizontal heavy duty including jointing material etc. complete ISI marked of size 80 mm bore for submersible pump complete all as specified and directed. |
| 30 | M&L for bends(any type, radius and angle)tapers any type (straight ,bend, increasing, decreasing or double socket etc.) Tee pieces single branch, \\"Y\\" junction, double branch, cross(all sockets or socket and spigot or all ends flanged) collars, caps and plugs complete all as specified and directed. Please Enable Macros to View BoQ information |