| 1 | Dismantling posts or struts (wood, steel or R.C.C.) anysection embedded in natural ground, including taking out embedded portion and making good disturbed ground complete all as specified and as directed. |
| 2 | Excavation in post holes in hard/dense soil each not exceeding 0.5 CUM, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm thick, watering and removing surplus soil to a distance not exceeding 50 metre and making good surface complete all as specified and as directed. |
| 3 | S&F mild steel angle iron post & strut etc. in fencing including embedding in concrete and screwing etc. including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 GdeE-165 completed all as specified and as directed. |
| 4 | S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and diameter of shank 5 to 10mm completed all as specified and as directed. |
| 5 | S&F Mild steel round or square bars 10mm dia and over for straining in available length, cut to length, bent to shape required Fe-410W (Gde E-250) quality 'A' complete all as specified and as directed. |
| 6 | M&L for PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed. |
| 7 | Supply only chain link fencing wire mesh of size 100x100mm, made with 4 mm dia mild steel galvanised wire complete all as specified and as directed.Note:- Unit weight of chain link fencing shall be ascertained through BOO as ordered by AGE (I). The same shall be submit before payment of RAR. |
| 8 | Fixing only chain link fencing wire mesh of size100x100mm, made with 4 mm dia mild steel galvanised wire etc including provision of binding wire complete all as specified and as directed. |
| 9 | S&F in repair concertina coil of 730mm to 800mm dia ,maximum stretch length of 6m fixed on steel post/struct to make a shape of concertina coils of 600 mm dia ,made with GI steel wire of 2.5 mm to 3mm, weight not less than 14 Kgs, having tensile strength 15 to 155 Kg / Sqmm, Blade 0.4mm to 0.6mm thick barbed Razor/ tear blade galvanized steel strip, 5 clips per spiral pair, made from High tensile Spring Steel High Carbon wire conforming to IS 4454: Part-I Grade-SM duly hot dipped galvanized, heavy zinc coating with minimum 275 gms per sqm. special heavy duty 'J' clips under for making concertina coils complete all as specified and directed.NOTE: The length of coil shall be measured after trectching and fixed in position |
| 10 | S & F galvanized two strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia bars at 75 mm spacing and straining and fixing to RCC / steel post etc., including securing or tying at crossing with and providing of galvanized mild steel wire, staples or steel pins, etc., (each line of wire to be measured separately) including dismantling of old barbed wire of any description complete all as specified and as directed. |
| 11 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 12 | M&L for preparation of new steel or iron surfaces of any description n exc 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 13 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cables, foundation for pole, etc and getting out in hard/dense soil complete all as specified and as directed. |
| 14 | Excavation in trenches exceeding 1.5 m wide and not exceeding 3.0 m in depth for laying cables, foundation for pole, etc and getting out in hard/dense soil complete all as specified and as directed. |
| 15 | Removing excavated soil to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed. |
| 16 | M&L for erection and fixing of steel tubular swaged pole type 410 SP - 31 (9.00 metres long) confirming to IS- 2713 Part I to III 1980 with and including cast iron base plate, finial taper plug, nuts, bolts and washers etc. fixed in PCC foundation duly painted painted with two coats of Aluminium paint over a coat of red oxide primer with 30 cm of black,yellow and white paint upto 1.2m including preparation of surface and including dismsntling of old pole of any size and description with foundation, PCC coping etc. complete all as specified and as directed. |
| 17 | M&L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 18 | M&L for PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 19 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping for the new/existing Steel Poles, cills, including necessary formwork (straight or curved) complete all as specified and as directed. |
| 20 | S &F street light fitting of 60 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP65,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage including taking down old unserviceable light fittings complete all as specified and as directed. |
| 21 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. |
| 22 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FR-LSH cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed. |
| 23 | S&F in repairs, Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed. |
| 24 | S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed. |
| 25 | S & F in repairs sheet metal enclosure when MCB to be used 2 way, Single pole & neutral without bus bar complete all as specified and asdirected. |
| 26 | S&F MCBs, SPN, 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 27 | S&F in repair LED Bollard light of 9watt, new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP65 luminaire for diffused lighting with high power LED as light source and including PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in foundation, nts, bolts etc complete all as specified and as directed. Make:- Havells, Model -BAMBOO LED BOLLARD, Cat no BAMBOOBL9WLED830SSYMTOPCM / Philips / crompton / Bajaj as approved by AGE(I). |
| 28 | S & F in repairs post top 15 watt new generation, IP65 LED, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and including PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in foundation, nuts, bolts etc complete all as specified and as directed. Make:- Havells, Model -RUBY NXT AND GENX LED POST TOP, Cat no RUBYNXTPT15WLED730PSYMTOPC / Philips / crompton / Bajaj as approved by AGE(I). |
| 29 | S & F in repairs LED Spike/Bush light 9W warm white with die-cast aluminium housing desined for rugged outdoor usage and IP65 protection and including PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in foundation, nuts, bolts etc complete all as specified and as directed. Make:- Bajaj, Cat No BGSBL 9W LED WW / Philips / crompton / Havells as approved by AGE(I).Note: For item No 1 to 5 Contractor have to write date of changing in bold letter using permanent marker and submit minimum two years manufacturer warrantee certificate with purchase voucher on completion of work. |
| 30 | S&F in repairs copper cunductor, 1.5 sqmm, 3 Core for secuirty light connection as per relevent IS Code and complete all as speified and directed. |
| 31 | S&F 1100 volts grade heavy duty flat cable of size 6 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any description complete all as specified and as directed. |
| 32 | M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I and including taking down of old ones, complete all as specified and directed. Please Enable Macros to View BoQ information |