| 1 | Excavation in post holes in hard/dense soil each not exceeding 0.5 CUM, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm thick, watering and removing surplus soil to a distance not exceeding 50 metre and making good surface complete all as specified and as directed. |
| 2 | S&F mild steel angle iron post & strut etc. in fencing including embedding in concrete and screwing etc. including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 GdeE-165 completed all as specified and as directed. |
| 3 | S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and diameter of shank 5 to 10mm completed all as specified and as directed. |
| 4 | S&F Mild steel round or square bars 10mm dia and over for straining in available length, cut to length, bent to shape required Fe-410W (Gde E-250) quality 'A' complete all as specified and as directed. |
| 5 | S&F rolled mild steel, Fe 410-W (Gde E-250) quality - A,for framed work as in doors or gates of angle or other sectionwith gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to beprepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, complete all as specified and directed. |
| 6 | M&L for PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed. |
| 7 | Supply only chain link fencing wire mesh of size 100x100mm, made with 4 mm dia mild steel galvanised wire complete all as specified and as directed.Note:- Unit weight of chain link fencing shall be ascertained through BOO as ordered by AGE (I). The same shall be submit before payment of RAR. |
| 8 | Fixing only chain link fencing wire mesh of size100x100mm, made with 4 mm dia mild steel galvanised wire etc including provision of binding wire complete all as specified and as directed. |
| 9 | S & F galvanized two strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia bars at 75 mm spacing and straining and fixing to RCC / steel post etc., including securing or tying at crossing with and providing of galvanized mild steel wire, staples or steel pins, etc., (each line of wire to be measured separately) including dismantling of old barbed wire of any description complete all as specified and as directed. |
| 10 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 11 | M&L for preparation of new steel or iron surfaces of any description n exc 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 12 | Excavating over areas, n exc1.5 m deep and getting out in hard /dense soil complete all as specified and as directed. |
| 13 | Excavating over areas, n exc1.5 m deep and n exc 3m deepand getting out in hard /dense soil complete all as specified and as directed. |
| 14 | Removing excavated soil to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed. |
| 15 | Returning, filling in, including spreading, levelling, watering and well ramming of soil in layers n. exc 25cm thick complete all as specified and as directed. |
| 16 | M&L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 17 | M&L for RCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete. complete all as specified and as directed.Note for item No.17 to 18: Reinforement shall be measured and paid separately under relevant item of this schedule. |
| 18 | M&L for RCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts, complete all as specified and as directed. |
| 19 | M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cutting, bending cranking, hooking end and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 20 | All as per item No 19 above but 8mm dia bars using for stirrups complete all as specified and as directed. |
| 21 | Formwork to rough finished surface sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 22 | Formwork to rough finished concrete surface sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. |
| 23 | M&L for 15mm thick rendering in cement mortar (1:4) of brick or concrete wall surfaces, finished even and smooth without using extra cement complete all as specified and as directed. |
| 24 | M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 25 | S &F street light fitting of 50 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP65,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage including mounting bracket etc complete all as specified and as directed. |
| 26 | S&F copper cunductor, 1.5 sqmm, 3 Core for secuirty light connection as per relevent IS Code and complete all as speified and directed. |
| 27 | S & F sheet metal enclosure when MCB to be used 2 way, Single pole & neutral without bus bar complete all as specified and asdirected. |
| 28 | S&F MCBs, SPN, 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 29 | S&F 1100 volts grade heavy duty flat cable of size 6 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any description complete all as specified and as directed. Please Enable Macros to View BoQ information |